Change
Water utility · Butler · Alabama

Butler Water System

No open health-based violations on EPA record in the last 10 years; latest legal-limit breach in the period starting April 2024.

Serves about 4,590 people (1,532 connections) with groundwater from its own wells.

  • PWSID AL0000232
  • EPA registered name: BUTLER WATER SYSTEM
  • EPA record checked May 18, 2026
Contact

Contact Butler Water System

From EPA's record for AL0000232. PurityMap is independent of Butler Water System.

Mailing address
P.O. BOX 455
BUTLER, AL 36915
Directions ↗

Are you this utility? Correct this listing →

EPA compliance record

What EPA's record shows

2 health-based violations in the last 10 years, from EPA's SDWIS compliance database.

  • Total trihalomethanes (TTHM), a by-product of disinfecting water with chlorine, were above the legal limit in 2 quarters since January 2024.
Recent health-based violations for Butler Water System (PWSID AL0000232)
PeriodContaminantMeasuredLegal limitEPA status
Apr–Jun 2024Total trihalomethanes (TTHM)0.089 mg/L0.080 mg/LResolved
Jan–Mar 2024Total trihalomethanes (TTHM)0.083 mg/L0.080 mg/LResolved
  • Lead: the 90th-percentile result in the latest lead and copper round (the round ending December 31, 2024) was 2.7 µg/L. The federal action level is 15 µg/L, a trigger for more treatment steps, not a legal limit.
  • Missed or late tests or reports: 4 in 10 years.
  • EPA lists 12 enforcement actions in 10 years; the latest on February 13, 2025.
Lab results EPA required (UCMR 5)

1 of 30 contaminants detected in EPA testing

EPA required this system to test for 30 unregulated and emerging contaminants, from May 2023 to November 2023.

  • LithiumAbove the referenced health-based guidance value
    10 µg/L EPA health reference level · not a legal limit
    23µg/L
Results as a table30 results with limit, status, sample date and source
EPA-required lab results (UCMR 5) for Butler Water System (PWSID AL0000232), Alabama
ContaminantResultLimitStatusSampledSource
Lithium23 µg/L10 µg/L EPA health reference level (screening, not a legal limit)Screening level, not a legal limitAbove the referenced health-based guidance value2023-05-02 to 2023-11-07UCMR5 Analytical Results: BUTLER WATER SYSTEM (AL0000232)
11-Chloroeicosafluoro-3-oxaundecane-1-sulfonic acid (11Cl-PF3OUdS)< 5 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2023-05-02 to 2023-11-07UCMR5 Analytical Results: BUTLER WATER SYSTEM (AL0000232)
1H, 1H, 2H, 2H-perfluorodecane sulfonic acid (8:2 FTS)< 5 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2023-05-02 to 2023-11-07UCMR5 Analytical Results: BUTLER WATER SYSTEM (AL0000232)
1H, 1H, 2H, 2H-perfluorohexane sulfonic acid (4:2 FTS)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2023-05-02 to 2023-11-07UCMR5 Analytical Results: BUTLER WATER SYSTEM (AL0000232)
1H, 1H, 2H, 2H-perfluorooctane sulfonic acid (6:2 FTS)< 5 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2023-05-02 to 2023-11-07UCMR5 Analytical Results: BUTLER WATER SYSTEM (AL0000232)
4,8-Dioxa-3H-perfluorononanoic acid (ADONA)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2023-05-02 to 2023-11-07UCMR5 Analytical Results: BUTLER WATER SYSTEM (AL0000232)
9-Chlorohexadecafluoro-3-oxanone-1-sulfonic acid (9Cl-PF3ONS)< 2 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2023-05-02 to 2023-11-07UCMR5 Analytical Results: BUTLER WATER SYSTEM (AL0000232)
Hexafluoropropylene oxide dimer acid (HFPO-DA) (GenX chemicals)< 5 ng/L10 ng/L federal MCL (2024)Not detected above the reporting limit2023-05-02 to 2023-11-07UCMR5 Analytical Results: BUTLER WATER SYSTEM (AL0000232)
N-ethyl perfluorooctanesulfonamidoacetic acid (NEtFOSAA)< 5 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2023-05-02 to 2023-11-07UCMR5 Analytical Results: BUTLER WATER SYSTEM (AL0000232)
N-methyl perfluorooctanesulfonamidoacetic acid (NMeFOSAA)< 6 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2023-05-02 to 2023-11-07UCMR5 Analytical Results: BUTLER WATER SYSTEM (AL0000232)
Nonafluoro-3,6-dioxaheptanoic acid (NFDHA)< 20 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2023-05-02 to 2023-11-07UCMR5 Analytical Results: BUTLER WATER SYSTEM (AL0000232)
Perfluoro (2-ethoxyethane) sulfonic acid (PFEESA)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2023-05-02 to 2023-11-07UCMR5 Analytical Results: BUTLER WATER SYSTEM (AL0000232)
Perfluoro-3-methoxypropanoic acid (PFMPA)< 4 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2023-05-02 to 2023-11-07UCMR5 Analytical Results: BUTLER WATER SYSTEM (AL0000232)
Perfluoro-4-methoxybutanoic acid (PFMBA)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2023-05-02 to 2023-11-07UCMR5 Analytical Results: BUTLER WATER SYSTEM (AL0000232)
Perfluorobutanesulfonic acid (PFBS)< 3 ng/L2,000 ng/L EPA health advisory (screening, not a legal limit)Screening level, not a legal limitNot detected above the reporting limit2023-05-02 to 2023-11-07UCMR5 Analytical Results: BUTLER WATER SYSTEM (AL0000232)
Perfluorobutanoic acid (PFBA)< 5 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2023-05-02 to 2023-11-07UCMR5 Analytical Results: BUTLER WATER SYSTEM (AL0000232)
Perfluorodecanoic acid (PFDA)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2023-05-02 to 2023-11-07UCMR5 Analytical Results: BUTLER WATER SYSTEM (AL0000232)
Perfluorododecanoic acid (PFDoA)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2023-05-02 to 2023-11-07UCMR5 Analytical Results: BUTLER WATER SYSTEM (AL0000232)
Perfluoroheptanesulfonic acid (PFHpS)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2023-05-02 to 2023-11-07UCMR5 Analytical Results: BUTLER WATER SYSTEM (AL0000232)
Perfluoroheptanoic acid (PFHpA)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2023-05-02 to 2023-11-07UCMR5 Analytical Results: BUTLER WATER SYSTEM (AL0000232)
Perfluorohexanesulfonic acid (PFHxS)< 3 ng/L10 ng/L federal MCL (2024)Not detected above the reporting limit2023-05-02 to 2023-11-07UCMR5 Analytical Results: BUTLER WATER SYSTEM (AL0000232)
Perfluorohexanoic acid (PFHxA)< 3 ng/L400,000 ng/L Michigan EGLE state MCL (strictest US state)Not detected above the reporting limit2023-05-02 to 2023-11-07UCMR5 Analytical Results: BUTLER WATER SYSTEM (AL0000232)
Perfluorononanoic acid (PFNA)< 4 ng/L10 ng/L federal MCL (2024)Not detected above the reporting limit2023-05-02 to 2023-11-07UCMR5 Analytical Results: BUTLER WATER SYSTEM (AL0000232)
Perfluorooctanesulfonic acid (PFOS)< 4 ng/L4.0 ng/L federal MCL (2024)Not detected above the reporting limit2023-05-02 to 2023-11-07UCMR5 Analytical Results: BUTLER WATER SYSTEM (AL0000232)
Perfluorooctanoic acid (PFOA)< 4 ng/L4.0 ng/L federal MCL (2024)Not detected above the reporting limit2023-05-02 to 2023-11-07UCMR5 Analytical Results: BUTLER WATER SYSTEM (AL0000232)
Perfluoropentanesulfonic acid (PFPeS)< 4 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2023-05-02 to 2023-11-07UCMR5 Analytical Results: BUTLER WATER SYSTEM (AL0000232)
Perfluoropentanoic acid (PFPeA)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2023-05-02 to 2023-11-07UCMR5 Analytical Results: BUTLER WATER SYSTEM (AL0000232)
Perfluorotetradecanoic acid (PFTA)< 8 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2023-05-02 to 2023-11-07UCMR5 Analytical Results: BUTLER WATER SYSTEM (AL0000232)
Perfluorotridecanoic acid (PFTrDA)< 7 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2023-05-02 to 2023-11-07UCMR5 Analytical Results: BUTLER WATER SYSTEM (AL0000232)
Perfluoroundecanoic acid (PFUnA)< 2 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2023-05-02 to 2023-11-07UCMR5 Analytical Results: BUTLER WATER SYSTEM (AL0000232)
Not detected (29)
  • 11-Chloroeicosafluoro-3-oxaundecane-1-sulfonic acid (11Cl-PF3OUdS)
  • 1H, 1H, 2H, 2H-perfluorohexane sulfonic acid (4:2 FTS)
  • 1H, 1H, 2H, 2H-perfluorooctane sulfonic acid (6:2 FTS)
  • 1H, 1H, 2H, 2H-perfluorodecane sulfonic acid (8:2 FTS)
  • 9-Chlorohexadecafluoro-3-oxanone-1-sulfonic acid (9Cl-PF3ONS)
  • 4,8-Dioxa-3H-perfluorononanoic acid (ADONA)
  • Hexafluoropropylene oxide dimer acid (HFPO-DA) (GenX chemicals)
  • N-ethyl perfluorooctanesulfonamidoacetic acid (NEtFOSAA)
  • Nonafluoro-3,6-dioxaheptanoic acid (NFDHA)
  • N-methyl perfluorooctanesulfonamidoacetic acid (NMeFOSAA)
  • Perfluorobutanoic acid (PFBA)
  • Perfluorobutanesulfonic acid (PFBS)
  • Perfluorodecanoic acid (PFDA)
  • Perfluorododecanoic acid (PFDoA)
  • Perfluoro (2-ethoxyethane) sulfonic acid (PFEESA)
  • Perfluoroheptanoic acid (PFHpA)
  • Perfluoroheptanesulfonic acid (PFHpS)
  • Perfluorohexanoic acid (PFHxA)
  • Perfluorohexanesulfonic acid (PFHxS)
  • Perfluoro-4-methoxybutanoic acid (PFMBA)
  • Perfluoro-3-methoxypropanoic acid (PFMPA)
  • Perfluorononanoic acid (PFNA)
  • Perfluorooctanoic acid (PFOA)
  • Perfluorooctanesulfonic acid (PFOS)
  • Perfluoropentanoic acid (PFPeA)
  • Perfluoropentanesulfonic acid (PFPeS)
  • Perfluorotetradecanoic acid (PFTA)
  • Perfluorotridecanoic acid (PFTrDA)
  • Perfluoroundecanoic acid (PFUnA)
Commercial · test your own tap

The system record stops at your property line

Screening tells you if something is worth a closer look; a lab result is the number you can act on.

As an Amazon Associate, PurityMap earns from qualifying purchases. Affiliate disclosure

  • Screening: quick check, not lab-grade

    Safe Home DIY Lead in Drinking Water Combo Test Kit

    Safe Home (EnviroTestKits)

    Lead, read as one of three ranges: 0–4, 5–15 or 15+ ppb

    Turnaround: 5 minutes

    What it can't tell you: It shows a lead range, not an exact level, and tests nothing else unless you pay extra for the optional lab test.

Questions

About Butler Water System

Follow Butler Water System

Get PurityMap updates about this water system.

Follow this water →
What is the phone number for Butler Water System?

Butler Water System's phone number on EPA record is 205-459-3795. Its mailing address is P.O. BOX 455, BUTLER, AL 36915.

Where does Butler Water System get its water?

According to EPA's record, Butler Water System uses groundwater from its own wells.

Does Butler Water System have any EPA violations?

EPA's record shows 2 health-based violations for Butler Water System in the 10 years to July 9, 2026. No open health-based violations on EPA record in the last 10 years. The latest legal-limit breach on record was in the period starting April 2024. EPA also lists 4 missed or late tests or reports in 10 years. The record comes from EPA's SDWIS compliance database.

What is Butler Water System's latest lead result?

The 90th-percentile lead result in Butler Water System's latest lead and copper round, which ended in December 2024, was 2.7 µg/L, below the federal action level of 15 µg/L.

Who do I contact about my Butler Water System water bill?

PurityMap has no verified website for Butler Water System. Its phone number on EPA record is 205-459-3795. Its mailing address on EPA record is P.O. BOX 455, BUTLER, AL 36915. Your water bill lists the ways to contact your supplier and pay. PurityMap does not take payments.