Change
Water utility · Vernon · Alabama

Vernon Water and Sewer Board

No open health-based violations on EPA record in the last 10 years; latest legal-limit breach in the period starting October 2016.

Serves about 9,801 people (3,267 connections) with groundwater from its own wells, and buys water from Guin Water & Sewer Board, City of Sulligent and Detroit Water Works.

  • PWSID AL0000773
  • EPA registered name: VERNON WATER AND SEWER BOARD
  • EPA record checked May 18, 2026
Contact

Contact Vernon Water and Sewer Board

From EPA's record for AL0000773. PurityMap is independent of Vernon Water and Sewer Board.

Mailing address
P.O. BOX 481
VERNON, AL 35592-3910
Directions ↗

Are you this utility? Correct this listing →

EPA compliance record

What EPA's record shows

1 health-based violation in the last 10 years, from EPA's SDWIS compliance database.

  • Haloacetic acids (HAA5), a by-product of disinfecting water with chlorine, were above the legal limit in the period starting October 2016.
Recent health-based violations for Vernon Water and Sewer Board (PWSID AL0000773)
PeriodContaminantMeasuredLegal limitEPA status
Oct–Dec 2016Haloacetic acids (HAA5)0.063 mg/L0.060 mg/LResolved
  • Lead: the 90th-percentile result in the latest lead and copper round (the round ending December 31, 2025) was not detected. The federal action level is 15 µg/L, a trigger for more treatment steps, not a legal limit.
  • Missed or late tests or reports: 1 in 10 years.
  • EPA lists 9 enforcement actions in 10 years; the latest on January 30, 2025.
Lab results EPA required (UCMR 5)

1 of 30 contaminants detected in EPA testing

EPA required this system to test for 30 unregulated and emerging contaminants, from March 2024 to December 2024.

  • Perfluorohexanesulfonic acid (PFHxS)Within a historical reference; current applicability unverified
    10 ng/L federal MCL
    5.9ng/L
Results as a table30 results with limit, status, sample date and source
EPA-required lab results (UCMR 5) for Vernon Water and Sewer Board (PWSID AL0000773), Alabama
ContaminantResultLimitStatusSampledSource
Perfluorohexanesulfonic acid (PFHxS)5.9 ng/L10 ng/L federal MCL (2024)Within a historical reference; current applicability unverified2024-03-05 to 2024-12-02UCMR5 Analytical Results: VERNON WATER AND SEWER BOARD (AL0000773)
11-Chloroeicosafluoro-3-oxaundecane-1-sulfonic acid (11Cl-PF3OUdS)< 5 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-03-05 to 2024-12-02UCMR5 Analytical Results: VERNON WATER AND SEWER BOARD (AL0000773)
1H, 1H, 2H, 2H-perfluorodecane sulfonic acid (8:2 FTS)< 5 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-03-05 to 2024-12-02UCMR5 Analytical Results: VERNON WATER AND SEWER BOARD (AL0000773)
1H, 1H, 2H, 2H-perfluorohexane sulfonic acid (4:2 FTS)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-03-05 to 2024-12-02UCMR5 Analytical Results: VERNON WATER AND SEWER BOARD (AL0000773)
1H, 1H, 2H, 2H-perfluorooctane sulfonic acid (6:2 FTS)< 5 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-03-05 to 2024-12-02UCMR5 Analytical Results: VERNON WATER AND SEWER BOARD (AL0000773)
4,8-Dioxa-3H-perfluorononanoic acid (ADONA)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-03-05 to 2024-12-02UCMR5 Analytical Results: VERNON WATER AND SEWER BOARD (AL0000773)
9-Chlorohexadecafluoro-3-oxanone-1-sulfonic acid (9Cl-PF3ONS)< 2 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-03-05 to 2024-12-02UCMR5 Analytical Results: VERNON WATER AND SEWER BOARD (AL0000773)
Hexafluoropropylene oxide dimer acid (HFPO-DA) (GenX chemicals)< 5 ng/L10 ng/L federal MCL (2024)Not detected above the reporting limit2024-03-05 to 2024-12-02UCMR5 Analytical Results: VERNON WATER AND SEWER BOARD (AL0000773)
Lithium< 9 µg/L10 µg/L EPA health reference level (screening, not a legal limit)Screening level, not a legal limitNot detected above the reporting limit2024-03-05 to 2024-12-02UCMR5 Analytical Results: VERNON WATER AND SEWER BOARD (AL0000773)
N-ethyl perfluorooctanesulfonamidoacetic acid (NEtFOSAA)< 5 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-03-05 to 2024-12-02UCMR5 Analytical Results: VERNON WATER AND SEWER BOARD (AL0000773)
N-methyl perfluorooctanesulfonamidoacetic acid (NMeFOSAA)< 6 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-03-05 to 2024-12-02UCMR5 Analytical Results: VERNON WATER AND SEWER BOARD (AL0000773)
Nonafluoro-3,6-dioxaheptanoic acid (NFDHA)< 20 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-03-05 to 2024-12-02UCMR5 Analytical Results: VERNON WATER AND SEWER BOARD (AL0000773)
Perfluoro (2-ethoxyethane) sulfonic acid (PFEESA)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-03-05 to 2024-12-02UCMR5 Analytical Results: VERNON WATER AND SEWER BOARD (AL0000773)
Perfluoro-3-methoxypropanoic acid (PFMPA)< 4 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-03-05 to 2024-12-02UCMR5 Analytical Results: VERNON WATER AND SEWER BOARD (AL0000773)
Perfluoro-4-methoxybutanoic acid (PFMBA)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-03-05 to 2024-12-02UCMR5 Analytical Results: VERNON WATER AND SEWER BOARD (AL0000773)
Perfluorobutanesulfonic acid (PFBS)< 3 ng/L2,000 ng/L EPA health advisory (screening, not a legal limit)Screening level, not a legal limitNot detected above the reporting limit2024-03-05 to 2024-12-02UCMR5 Analytical Results: VERNON WATER AND SEWER BOARD (AL0000773)
Perfluorobutanoic acid (PFBA)< 5 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-03-05 to 2024-12-02UCMR5 Analytical Results: VERNON WATER AND SEWER BOARD (AL0000773)
Perfluorodecanoic acid (PFDA)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-03-05 to 2024-12-02UCMR5 Analytical Results: VERNON WATER AND SEWER BOARD (AL0000773)
Perfluorododecanoic acid (PFDoA)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-03-05 to 2024-12-02UCMR5 Analytical Results: VERNON WATER AND SEWER BOARD (AL0000773)
Perfluoroheptanesulfonic acid (PFHpS)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-03-05 to 2024-12-02UCMR5 Analytical Results: VERNON WATER AND SEWER BOARD (AL0000773)
Perfluoroheptanoic acid (PFHpA)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-03-05 to 2024-12-02UCMR5 Analytical Results: VERNON WATER AND SEWER BOARD (AL0000773)
Perfluorohexanoic acid (PFHxA)< 3 ng/L400,000 ng/L Michigan EGLE state MCL (strictest US state)Not detected above the reporting limit2024-03-05 to 2024-12-02UCMR5 Analytical Results: VERNON WATER AND SEWER BOARD (AL0000773)
Perfluorononanoic acid (PFNA)< 4 ng/L10 ng/L federal MCL (2024)Not detected above the reporting limit2024-03-05 to 2024-12-02UCMR5 Analytical Results: VERNON WATER AND SEWER BOARD (AL0000773)
Perfluorooctanesulfonic acid (PFOS)< 4 ng/L4.0 ng/L federal MCL (2024)Not detected above the reporting limit2024-03-05 to 2024-12-02UCMR5 Analytical Results: VERNON WATER AND SEWER BOARD (AL0000773)
Perfluorooctanoic acid (PFOA)< 4 ng/L4.0 ng/L federal MCL (2024)Not detected above the reporting limit2024-03-05 to 2024-12-02UCMR5 Analytical Results: VERNON WATER AND SEWER BOARD (AL0000773)
Perfluoropentanesulfonic acid (PFPeS)< 4 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-03-05 to 2024-12-02UCMR5 Analytical Results: VERNON WATER AND SEWER BOARD (AL0000773)
Perfluoropentanoic acid (PFPeA)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-03-05 to 2024-12-02UCMR5 Analytical Results: VERNON WATER AND SEWER BOARD (AL0000773)
Perfluorotetradecanoic acid (PFTA)< 8 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-03-05 to 2024-12-02UCMR5 Analytical Results: VERNON WATER AND SEWER BOARD (AL0000773)
Perfluorotridecanoic acid (PFTrDA)< 7 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-03-05 to 2024-12-02UCMR5 Analytical Results: VERNON WATER AND SEWER BOARD (AL0000773)
Perfluoroundecanoic acid (PFUnA)< 2 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-03-05 to 2024-12-02UCMR5 Analytical Results: VERNON WATER AND SEWER BOARD (AL0000773)
Not detected (29)
  • 11-Chloroeicosafluoro-3-oxaundecane-1-sulfonic acid (11Cl-PF3OUdS)
  • 1H, 1H, 2H, 2H-perfluorohexane sulfonic acid (4:2 FTS)
  • 1H, 1H, 2H, 2H-perfluorooctane sulfonic acid (6:2 FTS)
  • 1H, 1H, 2H, 2H-perfluorodecane sulfonic acid (8:2 FTS)
  • 9-Chlorohexadecafluoro-3-oxanone-1-sulfonic acid (9Cl-PF3ONS)
  • 4,8-Dioxa-3H-perfluorononanoic acid (ADONA)
  • Hexafluoropropylene oxide dimer acid (HFPO-DA) (GenX chemicals)
  • N-ethyl perfluorooctanesulfonamidoacetic acid (NEtFOSAA)
  • Nonafluoro-3,6-dioxaheptanoic acid (NFDHA)
  • N-methyl perfluorooctanesulfonamidoacetic acid (NMeFOSAA)
  • Perfluorobutanoic acid (PFBA)
  • Perfluorobutanesulfonic acid (PFBS)
  • Perfluorodecanoic acid (PFDA)
  • Perfluorododecanoic acid (PFDoA)
  • Perfluoro (2-ethoxyethane) sulfonic acid (PFEESA)
  • Perfluoroheptanoic acid (PFHpA)
  • Perfluoroheptanesulfonic acid (PFHpS)
  • Perfluorohexanoic acid (PFHxA)
  • Perfluoro-4-methoxybutanoic acid (PFMBA)
  • Perfluoro-3-methoxypropanoic acid (PFMPA)
  • Perfluorononanoic acid (PFNA)
  • Perfluorooctanoic acid (PFOA)
  • Perfluorooctanesulfonic acid (PFOS)
  • Perfluoropentanoic acid (PFPeA)
  • Perfluoropentanesulfonic acid (PFPeS)
  • Perfluorotetradecanoic acid (PFTA)
  • Perfluorotridecanoic acid (PFTrDA)
  • Perfluoroundecanoic acid (PFUnA)
  • Lithium
Commercial · test your own tap

The system record stops at your property line

Screening tells you if something is worth a closer look; a lab result is the number you can act on.

As an Amazon Associate, PurityMap earns from qualifying purchases. Affiliate disclosure

  • Screening: quick check, not lab-grade

    Safe Home DIY Lead in Drinking Water Combo Test Kit

    Safe Home (EnviroTestKits)

    Lead, read as one of three ranges: 0–4, 5–15 or 15+ ppb

    Turnaround: 5 minutes

    What it can't tell you: It shows a lead range, not an exact level, and tests nothing else unless you pay extra for the optional lab test.

Questions

About Vernon Water and Sewer Board

Follow Vernon Water and Sewer Board

Get PurityMap updates about this water system.

Follow this water →
What is the phone number for Vernon Water and Sewer Board?

Vernon Water and Sewer Board's phone number on EPA record is 205-695-7302. Its mailing address is P.O. BOX 481, VERNON, AL 35592-3910.

Where does Vernon Water and Sewer Board get its water?

According to EPA's record, Vernon Water and Sewer Board uses groundwater from its own wells, and buys water from Guin Water & Sewer Board, City of Sulligent and Detroit Water Works.

Does Vernon Water and Sewer Board have any EPA violations?

EPA's record shows 1 health-based violation for Vernon Water and Sewer Board in the 10 years to July 9, 2026. No open health-based violations on EPA record in the last 10 years. The latest legal-limit breach on record was in the period starting October 2016. EPA also lists 1 missed or late test or report in 10 years. The record comes from EPA's SDWIS compliance database.

What is Vernon Water and Sewer Board's latest lead result?

Lead was not detected at the 90th percentile of tap samples in Vernon Water and Sewer Board's latest lead and copper round, which ended in December 2025. The federal action level is 15 µg/L.

Who do I contact about my Vernon Water and Sewer Board water bill?

PurityMap has no verified website for Vernon Water and Sewer Board. Its phone number on EPA record is 205-695-7302. Its mailing address on EPA record is P.O. BOX 481, VERNON, AL 35592-3910. Your water bill lists the ways to contact your supplier and pay. PurityMap does not take payments.