Change
Water utility · Monterey County · California

Alco Water Service

No health-based violations on EPA record since 2016.

Serves about 56,253 people (9,142 connections) with groundwater from its own wells.

  • PWSID CA2710001
  • EPA registered name: ALCO WATER SERVICE
  • EPA record checked June 22, 2026
Contact

Contact Alco Water Service

From EPA's record for CA2710001. PurityMap is independent of Alco Water Service.

Mailing address
249 WILLIAMS ROAD
SALINAS, CA 93905
Directions ↗

Are you this utility? Correct this listing →

EPA compliance record

What EPA's record shows

No health-based violations in the last 10 years, from EPA's SDWIS compliance database.

  • Lead: the 90th-percentile result in the latest lead and copper round (the round ending December 31, 2025) was not detected. The federal action level is 15 µg/L, a trigger for more treatment steps, not a legal limit.
  • Missed or late tests or reports: none in 10 years.
  • EPA lists no enforcement actions in 10 years.
Lab results EPA required (UCMR 5)

1 of 30 contaminants detected in EPA testing

EPA required this system to test for 30 unregulated and emerging contaminants, from March 2023 to September 2023.

  • LithiumAbove the referenced health-based guidance value
    10 µg/L EPA health reference level · not a legal limit
    65.1µg/L
Results as a table30 results with limit, status, sample date and source
EPA-required lab results (UCMR 5) for Alco Water Service (PWSID CA2710001), California
ContaminantResultLimitStatusSampledSource
Lithium65.1 µg/L10 µg/L EPA health reference level (screening, not a legal limit)Screening level, not a legal limitAbove the referenced health-based guidance value2023-03-07 to 2023-09-12UCMR5 Analytical Results: ALCO WATER SERVICE (CA2710001)
11-Chloroeicosafluoro-3-oxaundecane-1-sulfonic acid (11Cl-PF3OUdS)< 5 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2023-03-07 to 2023-09-12UCMR5 Analytical Results: ALCO WATER SERVICE (CA2710001)
1H, 1H, 2H, 2H-perfluorodecane sulfonic acid (8:2 FTS)< 5 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2023-03-07 to 2023-09-12UCMR5 Analytical Results: ALCO WATER SERVICE (CA2710001)
1H, 1H, 2H, 2H-perfluorohexane sulfonic acid (4:2 FTS)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2023-03-07 to 2023-09-12UCMR5 Analytical Results: ALCO WATER SERVICE (CA2710001)
1H, 1H, 2H, 2H-perfluorooctane sulfonic acid (6:2 FTS)< 5 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2023-03-07 to 2023-09-12UCMR5 Analytical Results: ALCO WATER SERVICE (CA2710001)
4,8-Dioxa-3H-perfluorononanoic acid (ADONA)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2023-03-07 to 2023-09-12UCMR5 Analytical Results: ALCO WATER SERVICE (CA2710001)
9-Chlorohexadecafluoro-3-oxanone-1-sulfonic acid (9Cl-PF3ONS)< 2 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2023-03-07 to 2023-09-12UCMR5 Analytical Results: ALCO WATER SERVICE (CA2710001)
Hexafluoropropylene oxide dimer acid (HFPO-DA) (GenX chemicals)< 5 ng/L10 ng/L federal MCL (2024)Not detected above the reporting limit2023-03-07 to 2023-09-12UCMR5 Analytical Results: ALCO WATER SERVICE (CA2710001)
N-ethyl perfluorooctanesulfonamidoacetic acid (NEtFOSAA)< 5 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2023-03-07 to 2023-09-12UCMR5 Analytical Results: ALCO WATER SERVICE (CA2710001)
N-methyl perfluorooctanesulfonamidoacetic acid (NMeFOSAA)< 6 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2023-03-07 to 2023-09-12UCMR5 Analytical Results: ALCO WATER SERVICE (CA2710001)
Nonafluoro-3,6-dioxaheptanoic acid (NFDHA)< 20 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2023-03-07 to 2023-09-12UCMR5 Analytical Results: ALCO WATER SERVICE (CA2710001)
Perfluoro (2-ethoxyethane) sulfonic acid (PFEESA)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2023-03-07 to 2023-09-12UCMR5 Analytical Results: ALCO WATER SERVICE (CA2710001)
Perfluoro-3-methoxypropanoic acid (PFMPA)< 4 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2023-03-07 to 2023-09-12UCMR5 Analytical Results: ALCO WATER SERVICE (CA2710001)
Perfluoro-4-methoxybutanoic acid (PFMBA)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2023-03-07 to 2023-09-12UCMR5 Analytical Results: ALCO WATER SERVICE (CA2710001)
Perfluorobutanesulfonic acid (PFBS)< 3 ng/L2,000 ng/L EPA health advisory (screening, not a legal limit)Screening level, not a legal limitNot detected above the reporting limit2023-03-07 to 2023-09-12UCMR5 Analytical Results: ALCO WATER SERVICE (CA2710001)
Perfluorobutanoic acid (PFBA)< 5 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2023-03-07 to 2023-09-12UCMR5 Analytical Results: ALCO WATER SERVICE (CA2710001)
Perfluorodecanoic acid (PFDA)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2023-03-07 to 2023-09-12UCMR5 Analytical Results: ALCO WATER SERVICE (CA2710001)
Perfluorododecanoic acid (PFDoA)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2023-03-07 to 2023-09-12UCMR5 Analytical Results: ALCO WATER SERVICE (CA2710001)
Perfluoroheptanesulfonic acid (PFHpS)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2023-03-07 to 2023-09-12UCMR5 Analytical Results: ALCO WATER SERVICE (CA2710001)
Perfluoroheptanoic acid (PFHpA)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2023-03-07 to 2023-09-12UCMR5 Analytical Results: ALCO WATER SERVICE (CA2710001)
Perfluorohexanesulfonic acid (PFHxS)< 3 ng/L10 ng/L federal MCL (2024)Not detected above the reporting limit2023-03-07 to 2023-09-12UCMR5 Analytical Results: ALCO WATER SERVICE (CA2710001)
Perfluorohexanoic acid (PFHxA)< 3 ng/L400,000 ng/L Michigan EGLE state MCL (strictest US state)Not detected above the reporting limit2023-03-07 to 2023-09-12UCMR5 Analytical Results: ALCO WATER SERVICE (CA2710001)
Perfluorononanoic acid (PFNA)< 4 ng/L10 ng/L federal MCL (2024)Not detected above the reporting limit2023-03-07 to 2023-09-12UCMR5 Analytical Results: ALCO WATER SERVICE (CA2710001)
Perfluorooctanesulfonic acid (PFOS)< 4 ng/L4.0 ng/L federal MCL (2024)Not detected above the reporting limit2023-03-07 to 2023-09-12UCMR5 Analytical Results: ALCO WATER SERVICE (CA2710001)
Perfluorooctanoic acid (PFOA)< 4 ng/L4.0 ng/L federal MCL (2024)Not detected above the reporting limit2023-03-07 to 2023-09-12UCMR5 Analytical Results: ALCO WATER SERVICE (CA2710001)
Perfluoropentanesulfonic acid (PFPeS)< 4 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2023-03-07 to 2023-09-12UCMR5 Analytical Results: ALCO WATER SERVICE (CA2710001)
Perfluoropentanoic acid (PFPeA)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2023-03-07 to 2023-09-12UCMR5 Analytical Results: ALCO WATER SERVICE (CA2710001)
Perfluorotetradecanoic acid (PFTA)< 8 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2023-03-07 to 2023-09-12UCMR5 Analytical Results: ALCO WATER SERVICE (CA2710001)
Perfluorotridecanoic acid (PFTrDA)< 7 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2023-03-07 to 2023-09-12UCMR5 Analytical Results: ALCO WATER SERVICE (CA2710001)
Perfluoroundecanoic acid (PFUnA)< 2 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2023-03-07 to 2023-09-12UCMR5 Analytical Results: ALCO WATER SERVICE (CA2710001)
Not detected (29)
  • 11-Chloroeicosafluoro-3-oxaundecane-1-sulfonic acid (11Cl-PF3OUdS)
  • 1H, 1H, 2H, 2H-perfluorohexane sulfonic acid (4:2 FTS)
  • 1H, 1H, 2H, 2H-perfluorooctane sulfonic acid (6:2 FTS)
  • 1H, 1H, 2H, 2H-perfluorodecane sulfonic acid (8:2 FTS)
  • 9-Chlorohexadecafluoro-3-oxanone-1-sulfonic acid (9Cl-PF3ONS)
  • 4,8-Dioxa-3H-perfluorononanoic acid (ADONA)
  • Hexafluoropropylene oxide dimer acid (HFPO-DA) (GenX chemicals)
  • N-ethyl perfluorooctanesulfonamidoacetic acid (NEtFOSAA)
  • Nonafluoro-3,6-dioxaheptanoic acid (NFDHA)
  • N-methyl perfluorooctanesulfonamidoacetic acid (NMeFOSAA)
  • Perfluorobutanoic acid (PFBA)
  • Perfluorobutanesulfonic acid (PFBS)
  • Perfluorodecanoic acid (PFDA)
  • Perfluorododecanoic acid (PFDoA)
  • Perfluoro (2-ethoxyethane) sulfonic acid (PFEESA)
  • Perfluoroheptanoic acid (PFHpA)
  • Perfluoroheptanesulfonic acid (PFHpS)
  • Perfluorohexanoic acid (PFHxA)
  • Perfluorohexanesulfonic acid (PFHxS)
  • Perfluoro-4-methoxybutanoic acid (PFMBA)
  • Perfluoro-3-methoxypropanoic acid (PFMPA)
  • Perfluorononanoic acid (PFNA)
  • Perfluorooctanoic acid (PFOA)
  • Perfluorooctanesulfonic acid (PFOS)
  • Perfluoropentanoic acid (PFPeA)
  • Perfluoropentanesulfonic acid (PFPeS)
  • Perfluorotetradecanoic acid (PFTA)
  • Perfluorotridecanoic acid (PFTrDA)
  • Perfluoroundecanoic acid (PFUnA)
Commercial · test your own tap

The system record stops at your property line

Screening tells you if something is worth a closer look; a lab result is the number you can act on.

As an Amazon Associate, PurityMap earns from qualifying purchases. Affiliate disclosure

  • Screening: quick check, not lab-grade

    Safe Home DIY Lead in Drinking Water Combo Test Kit

    Safe Home (EnviroTestKits)

    Lead, read as one of three ranges: 0–4, 5–15 or 15+ ppb

    Turnaround: 5 minutes

    What it can't tell you: It shows a lead range, not an exact level, and tests nothing else unless you pay extra for the optional lab test.

Questions

About Alco Water Service

Follow Alco Water Service

Get PurityMap updates about this water system.

Follow this water →
What is the phone number for Alco Water Service?

Alco Water Service's phone number on EPA record is 831-424-0441. Its mailing address is 249 WILLIAMS ROAD, SALINAS, CA 93905.

Where does Alco Water Service get its water?

According to EPA's record, Alco Water Service uses groundwater from its own wells.

Does Alco Water Service have any EPA violations?

No health-based violations on EPA record since 2016. The record comes from EPA's SDWIS compliance database.

What is Alco Water Service's latest lead result?

Lead was not detected at the 90th percentile of tap samples in Alco Water Service's latest lead and copper round, which ended in December 2025. The federal action level is 15 µg/L.

Who do I contact about my Alco Water Service water bill?

PurityMap has no verified website for Alco Water Service. Its phone number on EPA record is 831-424-0441. Its mailing address on EPA record is 249 WILLIAMS ROAD, SALINAS, CA 93905. Your water bill lists the ways to contact your supplier and pay. PurityMap does not take payments.