No health-based violations on EPA record since 2016.

Serves about 3,153 people (82 connections) with groundwater from its own wells.

  • PWSID FL1650791
  • EPA registered name: WINCO UTILITIES W/S
  • EPA record checked May 18, 2026
Contact

Contact Winco Utilities W/S

From EPA's record for FL1650791. PurityMap is independent of Winco Utilities W/S.

Mailing address
PO BOX 6937
JACKSONVILLE, FL 32236
Directions ↗

Are you this utility? Correct this listing →

EPA compliance record

What EPA's record shows

No health-based violations in the last 10 years, from EPA's SDWIS compliance database.

  • Lead: the 90th-percentile result in the latest lead and copper round (the round ending December 1, 2023) was 3 µg/L. The federal action level is 15 µg/L, a trigger for more treatment steps, not a legal limit.
  • Missed or late tests or reports: none in 10 years.
  • EPA lists 1 enforcement action in 10 years; the latest on October 12, 2017.
Lab results EPA required (UCMR 5)

None of the contaminants were detected in EPA testing

EPA required this system to test for 30 unregulated and emerging contaminants, from March 2024 to September 2024.

Results as a table30 results with limit, status, sample date and source
EPA-required lab results (UCMR 5) for Winco Utilities W/S (PWSID FL1650791), Florida
ContaminantResultLimitStatusSampledSource
11-Chloroeicosafluoro-3-oxaundecane-1-sulfonic acid (11Cl-PF3OUdS)< 5 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-03-04 to 2024-09-09UCMR5 Analytical Results: WINCO UTILITIES W/S (FL1650791)
1H, 1H, 2H, 2H-perfluorodecane sulfonic acid (8:2 FTS)< 5 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-03-04 to 2024-09-09UCMR5 Analytical Results: WINCO UTILITIES W/S (FL1650791)
1H, 1H, 2H, 2H-perfluorohexane sulfonic acid (4:2 FTS)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-03-04 to 2024-09-09UCMR5 Analytical Results: WINCO UTILITIES W/S (FL1650791)
1H, 1H, 2H, 2H-perfluorooctane sulfonic acid (6:2 FTS)< 5 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-03-04 to 2024-09-09UCMR5 Analytical Results: WINCO UTILITIES W/S (FL1650791)
4,8-Dioxa-3H-perfluorononanoic acid (ADONA)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-03-04 to 2024-09-09UCMR5 Analytical Results: WINCO UTILITIES W/S (FL1650791)
9-Chlorohexadecafluoro-3-oxanone-1-sulfonic acid (9Cl-PF3ONS)< 2 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-03-04 to 2024-09-09UCMR5 Analytical Results: WINCO UTILITIES W/S (FL1650791)
Hexafluoropropylene oxide dimer acid (HFPO-DA) (GenX chemicals)< 5 ng/L10 ng/L federal MCL (2024)Not detected above the reporting limit2024-03-04 to 2024-09-09UCMR5 Analytical Results: WINCO UTILITIES W/S (FL1650791)
Lithium< 9 µg/L10 µg/L EPA health reference level (screening, not a legal limit)Screening level, not a legal limitNot detected above the reporting limit2024-03-04 to 2024-09-09UCMR5 Analytical Results: WINCO UTILITIES W/S (FL1650791)
N-ethyl perfluorooctanesulfonamidoacetic acid (NEtFOSAA)< 5 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-03-04 to 2024-09-09UCMR5 Analytical Results: WINCO UTILITIES W/S (FL1650791)
N-methyl perfluorooctanesulfonamidoacetic acid (NMeFOSAA)< 6 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-03-04 to 2024-09-09UCMR5 Analytical Results: WINCO UTILITIES W/S (FL1650791)
Nonafluoro-3,6-dioxaheptanoic acid (NFDHA)< 20 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-03-04 to 2024-09-09UCMR5 Analytical Results: WINCO UTILITIES W/S (FL1650791)
Perfluoro (2-ethoxyethane) sulfonic acid (PFEESA)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-03-04 to 2024-09-09UCMR5 Analytical Results: WINCO UTILITIES W/S (FL1650791)
Perfluoro-3-methoxypropanoic acid (PFMPA)< 4 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-03-04 to 2024-09-09UCMR5 Analytical Results: WINCO UTILITIES W/S (FL1650791)
Perfluoro-4-methoxybutanoic acid (PFMBA)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-03-04 to 2024-09-09UCMR5 Analytical Results: WINCO UTILITIES W/S (FL1650791)
Perfluorobutanesulfonic acid (PFBS)< 3 ng/L2,000 ng/L EPA health advisory (screening, not a legal limit)Screening level, not a legal limitNot detected above the reporting limit2024-03-04 to 2024-09-09UCMR5 Analytical Results: WINCO UTILITIES W/S (FL1650791)
Perfluorobutanoic acid (PFBA)< 5 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-03-04 to 2024-09-09UCMR5 Analytical Results: WINCO UTILITIES W/S (FL1650791)
Perfluorodecanoic acid (PFDA)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-03-04 to 2024-09-09UCMR5 Analytical Results: WINCO UTILITIES W/S (FL1650791)
Perfluorododecanoic acid (PFDoA)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-03-04 to 2024-09-09UCMR5 Analytical Results: WINCO UTILITIES W/S (FL1650791)
Perfluoroheptanesulfonic acid (PFHpS)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-03-04 to 2024-09-09UCMR5 Analytical Results: WINCO UTILITIES W/S (FL1650791)
Perfluoroheptanoic acid (PFHpA)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-03-04 to 2024-09-09UCMR5 Analytical Results: WINCO UTILITIES W/S (FL1650791)
Perfluorohexanesulfonic acid (PFHxS)< 3 ng/L10 ng/L federal MCL (2024)Not detected above the reporting limit2024-03-04 to 2024-09-09UCMR5 Analytical Results: WINCO UTILITIES W/S (FL1650791)
Perfluorohexanoic acid (PFHxA)< 3 ng/L400,000 ng/L Michigan EGLE state MCL (strictest US state)Not detected above the reporting limit2024-03-04 to 2024-09-09UCMR5 Analytical Results: WINCO UTILITIES W/S (FL1650791)
Perfluorononanoic acid (PFNA)< 4 ng/L10 ng/L federal MCL (2024)Not detected above the reporting limit2024-03-04 to 2024-09-09UCMR5 Analytical Results: WINCO UTILITIES W/S (FL1650791)
Perfluorooctanesulfonic acid (PFOS)< 4 ng/L4.0 ng/L federal MCL (2024)Not detected above the reporting limit2024-03-04 to 2024-09-09UCMR5 Analytical Results: WINCO UTILITIES W/S (FL1650791)
Perfluorooctanoic acid (PFOA)< 4 ng/L4.0 ng/L federal MCL (2024)Not detected above the reporting limit2024-03-04 to 2024-09-09UCMR5 Analytical Results: WINCO UTILITIES W/S (FL1650791)
Perfluoropentanesulfonic acid (PFPeS)< 4 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-03-04 to 2024-09-09UCMR5 Analytical Results: WINCO UTILITIES W/S (FL1650791)
Perfluoropentanoic acid (PFPeA)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-03-04 to 2024-09-09UCMR5 Analytical Results: WINCO UTILITIES W/S (FL1650791)
Perfluorotetradecanoic acid (PFTA)< 8 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-03-04 to 2024-09-09UCMR5 Analytical Results: WINCO UTILITIES W/S (FL1650791)
Perfluorotridecanoic acid (PFTrDA)< 7 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-03-04 to 2024-09-09UCMR5 Analytical Results: WINCO UTILITIES W/S (FL1650791)
Perfluoroundecanoic acid (PFUnA)< 2 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-03-04 to 2024-09-09UCMR5 Analytical Results: WINCO UTILITIES W/S (FL1650791)
Not detected (30)
  • 11-Chloroeicosafluoro-3-oxaundecane-1-sulfonic acid (11Cl-PF3OUdS)
  • 1H, 1H, 2H, 2H-perfluorohexane sulfonic acid (4:2 FTS)
  • 1H, 1H, 2H, 2H-perfluorooctane sulfonic acid (6:2 FTS)
  • 1H, 1H, 2H, 2H-perfluorodecane sulfonic acid (8:2 FTS)
  • 9-Chlorohexadecafluoro-3-oxanone-1-sulfonic acid (9Cl-PF3ONS)
  • 4,8-Dioxa-3H-perfluorononanoic acid (ADONA)
  • Hexafluoropropylene oxide dimer acid (HFPO-DA) (GenX chemicals)
  • N-ethyl perfluorooctanesulfonamidoacetic acid (NEtFOSAA)
  • Nonafluoro-3,6-dioxaheptanoic acid (NFDHA)
  • N-methyl perfluorooctanesulfonamidoacetic acid (NMeFOSAA)
  • Perfluorobutanoic acid (PFBA)
  • Perfluorobutanesulfonic acid (PFBS)
  • Perfluorodecanoic acid (PFDA)
  • Perfluorododecanoic acid (PFDoA)
  • Perfluoro (2-ethoxyethane) sulfonic acid (PFEESA)
  • Perfluoroheptanoic acid (PFHpA)
  • Perfluoroheptanesulfonic acid (PFHpS)
  • Perfluorohexanoic acid (PFHxA)
  • Perfluorohexanesulfonic acid (PFHxS)
  • Perfluoro-4-methoxybutanoic acid (PFMBA)
  • Perfluoro-3-methoxypropanoic acid (PFMPA)
  • Perfluorononanoic acid (PFNA)
  • Perfluorooctanoic acid (PFOA)
  • Perfluorooctanesulfonic acid (PFOS)
  • Perfluoropentanoic acid (PFPeA)
  • Perfluoropentanesulfonic acid (PFPeS)
  • Perfluorotetradecanoic acid (PFTA)
  • Perfluorotridecanoic acid (PFTrDA)
  • Perfluoroundecanoic acid (PFUnA)
  • Lithium
Commercial · test your own tap

The system record stops at your property line

Screening tells you if something is worth a closer look; a lab result is the number you can act on.

As an Amazon Associate, PurityMap earns from qualifying purchases. Affiliate disclosure

  • Screening: quick check, not lab-grade

    Safe Home DIY Lead in Drinking Water Combo Test Kit

    Safe Home (EnviroTestKits)

    Lead, read as one of three ranges: 0–4, 5–15 or 15+ ppb

    Turnaround: 5 minutes

    What it can't tell you: It shows a lead range, not an exact level, and tests nothing else unless you pay extra for the optional lab test.

Questions

About Winco Utilities W/S

Follow Winco Utilities W/S

Get PurityMap updates about this water system.

Follow this water →
What is the phone number for Winco Utilities W/S?

Winco Utilities W/S's phone number on EPA record is 904-270-9262. Its mailing address is PO BOX 6937, JACKSONVILLE, FL 32236.

Where does Winco Utilities W/S get its water?

According to EPA's record, Winco Utilities W/S uses groundwater from its own wells.

Does Winco Utilities W/S have any EPA violations?

No health-based violations on EPA record since 2016. The record comes from EPA's SDWIS compliance database.

What is Winco Utilities W/S's latest lead result?

The 90th-percentile lead result in Winco Utilities W/S's latest lead and copper round, which ended in December 2023, was 3 µg/L, below the federal action level of 15 µg/L.

Who do I contact about my Winco Utilities W/S water bill?

PurityMap has no verified website for Winco Utilities W/S. Its phone number on EPA record is 904-270-9262. Its mailing address on EPA record is PO BOX 6937, JACKSONVILLE, FL 32236. Your water bill lists the ways to contact your supplier and pay. PurityMap does not take payments.