Change
Water utility · Galena · Indiana

Greenville Water Utility

No health-based violations on EPA record since 2016.

Serves about 4,920 people (1,612 connections) with groundwater bought from Indiana American Water, Edwardsville Water Corporation and Floyds Knobs Water Company, Inc..

  • PWSID IN5222004
  • EPA registered name: GREENVILLE WATER UTILITY
  • EPA record checked June 30, 2026
Contact

Contact Greenville Water Utility

From EPA's record for IN5222004. PurityMap is independent of Greenville Water Utility.

Mailing address
P.O. Box 188
GREENVILLE, IN 47124
Directions ↗

Are you this utility? Correct this listing →

EPA compliance record

What EPA's record shows

No health-based violations in the last 10 years, from EPA's SDWIS compliance database.

  • Lead: the 90th-percentile result in the latest lead and copper round (the round ending December 31, 2024) was 1.31 µg/L. The federal action level is 15 µg/L, a trigger for more treatment steps, not a legal limit.
  • Missed or late tests or reports: none in 10 years.
  • EPA lists no enforcement actions in 10 years.
Lab results EPA required (UCMR 5)

2 of 30 contaminants detected in EPA testing

EPA required this system to test for 30 unregulated and emerging contaminants, from February 2024 to October 2024.

  • Perfluorooctanoic acid (PFOA)Above a historical reference; current applicability unverified
    4 ng/L federal MCL
    7.2ng/L
  • Perfluorobutanesulfonic acid (PFBS)Within the referenced health-based guidance value
    2,000 ng/L EPA health advisory · not a legal limit
    3ng/L
Results as a table30 results with limit, status, sample date and source
EPA-required lab results (UCMR 5) for Greenville Water Utility (PWSID IN5222004), Indiana
ContaminantResultLimitStatusSampledSource
Perfluorooctanoic acid (PFOA)7.2 ng/L4.0 ng/L federal MCL (2024)Above a historical reference; current applicability unverified2024-02-06 to 2024-10-08UCMR5 Analytical Results: GREENVILLE WATER UTILITY (IN5222004)
Perfluorobutanesulfonic acid (PFBS)3 ng/L2,000 ng/L EPA health advisory (screening, not a legal limit)Screening level, not a legal limitWithin the referenced health-based guidance value2024-02-06 to 2024-10-08UCMR5 Analytical Results: GREENVILLE WATER UTILITY (IN5222004)
11-Chloroeicosafluoro-3-oxaundecane-1-sulfonic acid (11Cl-PF3OUdS)< 5 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-02-06 to 2024-10-08UCMR5 Analytical Results: GREENVILLE WATER UTILITY (IN5222004)
1H, 1H, 2H, 2H-perfluorodecane sulfonic acid (8:2 FTS)< 5 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-02-06 to 2024-10-08UCMR5 Analytical Results: GREENVILLE WATER UTILITY (IN5222004)
1H, 1H, 2H, 2H-perfluorohexane sulfonic acid (4:2 FTS)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-02-06 to 2024-10-08UCMR5 Analytical Results: GREENVILLE WATER UTILITY (IN5222004)
1H, 1H, 2H, 2H-perfluorooctane sulfonic acid (6:2 FTS)< 5 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-02-06 to 2024-10-08UCMR5 Analytical Results: GREENVILLE WATER UTILITY (IN5222004)
4,8-Dioxa-3H-perfluorononanoic acid (ADONA)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-02-06 to 2024-10-08UCMR5 Analytical Results: GREENVILLE WATER UTILITY (IN5222004)
9-Chlorohexadecafluoro-3-oxanone-1-sulfonic acid (9Cl-PF3ONS)< 2 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-02-06 to 2024-10-08UCMR5 Analytical Results: GREENVILLE WATER UTILITY (IN5222004)
Hexafluoropropylene oxide dimer acid (HFPO-DA) (GenX chemicals)< 5 ng/L10 ng/L federal MCL (2024)Not detected above the reporting limit2024-02-06 to 2024-10-08UCMR5 Analytical Results: GREENVILLE WATER UTILITY (IN5222004)
Lithium< 9 µg/L10 µg/L EPA health reference level (screening, not a legal limit)Screening level, not a legal limitNot detected above the reporting limit2024-02-06 to 2024-10-08UCMR5 Analytical Results: GREENVILLE WATER UTILITY (IN5222004)
N-ethyl perfluorooctanesulfonamidoacetic acid (NEtFOSAA)< 5 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-02-06 to 2024-10-08UCMR5 Analytical Results: GREENVILLE WATER UTILITY (IN5222004)
N-methyl perfluorooctanesulfonamidoacetic acid (NMeFOSAA)< 6 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-02-06 to 2024-10-08UCMR5 Analytical Results: GREENVILLE WATER UTILITY (IN5222004)
Nonafluoro-3,6-dioxaheptanoic acid (NFDHA)< 20 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-02-06 to 2024-10-08UCMR5 Analytical Results: GREENVILLE WATER UTILITY (IN5222004)
Perfluoro (2-ethoxyethane) sulfonic acid (PFEESA)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-02-06 to 2024-10-08UCMR5 Analytical Results: GREENVILLE WATER UTILITY (IN5222004)
Perfluoro-3-methoxypropanoic acid (PFMPA)< 4 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-02-06 to 2024-10-08UCMR5 Analytical Results: GREENVILLE WATER UTILITY (IN5222004)
Perfluoro-4-methoxybutanoic acid (PFMBA)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-02-06 to 2024-10-08UCMR5 Analytical Results: GREENVILLE WATER UTILITY (IN5222004)
Perfluorobutanoic acid (PFBA)< 5 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-02-06 to 2024-10-08UCMR5 Analytical Results: GREENVILLE WATER UTILITY (IN5222004)
Perfluorodecanoic acid (PFDA)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-02-06 to 2024-10-08UCMR5 Analytical Results: GREENVILLE WATER UTILITY (IN5222004)
Perfluorododecanoic acid (PFDoA)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-02-06 to 2024-10-08UCMR5 Analytical Results: GREENVILLE WATER UTILITY (IN5222004)
Perfluoroheptanesulfonic acid (PFHpS)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-02-06 to 2024-10-08UCMR5 Analytical Results: GREENVILLE WATER UTILITY (IN5222004)
Perfluoroheptanoic acid (PFHpA)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-02-06 to 2024-10-08UCMR5 Analytical Results: GREENVILLE WATER UTILITY (IN5222004)
Perfluorohexanesulfonic acid (PFHxS)< 3 ng/L10 ng/L federal MCL (2024)Not detected above the reporting limit2024-02-06 to 2024-10-08UCMR5 Analytical Results: GREENVILLE WATER UTILITY (IN5222004)
Perfluorohexanoic acid (PFHxA)< 3 ng/L400,000 ng/L Michigan EGLE state MCL (strictest US state)Not detected above the reporting limit2024-02-06 to 2024-10-08UCMR5 Analytical Results: GREENVILLE WATER UTILITY (IN5222004)
Perfluorononanoic acid (PFNA)< 4 ng/L10 ng/L federal MCL (2024)Not detected above the reporting limit2024-02-06 to 2024-10-08UCMR5 Analytical Results: GREENVILLE WATER UTILITY (IN5222004)
Perfluorooctanesulfonic acid (PFOS)< 4 ng/L4.0 ng/L federal MCL (2024)Not detected above the reporting limit2024-02-06 to 2024-10-08UCMR5 Analytical Results: GREENVILLE WATER UTILITY (IN5222004)
Perfluoropentanesulfonic acid (PFPeS)< 4 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-02-06 to 2024-10-08UCMR5 Analytical Results: GREENVILLE WATER UTILITY (IN5222004)
Perfluoropentanoic acid (PFPeA)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-02-06 to 2024-10-08UCMR5 Analytical Results: GREENVILLE WATER UTILITY (IN5222004)
Perfluorotetradecanoic acid (PFTA)< 8 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-02-06 to 2024-10-08UCMR5 Analytical Results: GREENVILLE WATER UTILITY (IN5222004)
Perfluorotridecanoic acid (PFTrDA)< 7 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-02-06 to 2024-10-08UCMR5 Analytical Results: GREENVILLE WATER UTILITY (IN5222004)
Perfluoroundecanoic acid (PFUnA)< 2 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-02-06 to 2024-10-08UCMR5 Analytical Results: GREENVILLE WATER UTILITY (IN5222004)
Not detected (28)
  • 11-Chloroeicosafluoro-3-oxaundecane-1-sulfonic acid (11Cl-PF3OUdS)
  • 1H, 1H, 2H, 2H-perfluorohexane sulfonic acid (4:2 FTS)
  • 1H, 1H, 2H, 2H-perfluorooctane sulfonic acid (6:2 FTS)
  • 1H, 1H, 2H, 2H-perfluorodecane sulfonic acid (8:2 FTS)
  • 9-Chlorohexadecafluoro-3-oxanone-1-sulfonic acid (9Cl-PF3ONS)
  • 4,8-Dioxa-3H-perfluorononanoic acid (ADONA)
  • Hexafluoropropylene oxide dimer acid (HFPO-DA) (GenX chemicals)
  • N-ethyl perfluorooctanesulfonamidoacetic acid (NEtFOSAA)
  • Nonafluoro-3,6-dioxaheptanoic acid (NFDHA)
  • N-methyl perfluorooctanesulfonamidoacetic acid (NMeFOSAA)
  • Perfluorobutanoic acid (PFBA)
  • Perfluorodecanoic acid (PFDA)
  • Perfluorododecanoic acid (PFDoA)
  • Perfluoro (2-ethoxyethane) sulfonic acid (PFEESA)
  • Perfluoroheptanoic acid (PFHpA)
  • Perfluoroheptanesulfonic acid (PFHpS)
  • Perfluorohexanoic acid (PFHxA)
  • Perfluorohexanesulfonic acid (PFHxS)
  • Perfluoro-4-methoxybutanoic acid (PFMBA)
  • Perfluoro-3-methoxypropanoic acid (PFMPA)
  • Perfluorononanoic acid (PFNA)
  • Perfluorooctanesulfonic acid (PFOS)
  • Perfluoropentanoic acid (PFPeA)
  • Perfluoropentanesulfonic acid (PFPeS)
  • Perfluorotetradecanoic acid (PFTA)
  • Perfluorotridecanoic acid (PFTrDA)
  • Perfluoroundecanoic acid (PFUnA)
  • Lithium
Commercial · test your own tap

The system record stops at your property line

Screening tells you if something is worth a closer look; a lab result is the number you can act on.

As an Amazon Associate, PurityMap earns from qualifying purchases. Affiliate disclosure

  • Screening: quick check, not lab-grade

    Safe Home DIY Lead in Drinking Water Combo Test Kit

    Safe Home (EnviroTestKits)

    Lead, read as one of three ranges: 0–4, 5–15 or 15+ ppb

    Turnaround: 5 minutes

    What it can't tell you: It shows a lead range, not an exact level, and tests nothing else unless you pay extra for the optional lab test.

Questions

About Greenville Water Utility

Follow Greenville Water Utility

Get PurityMap updates about this water system.

Follow this water →
What is the phone number for Greenville Water Utility?

Greenville Water Utility's phone number on EPA record is 812-267-2808. Its mailing address is P.O. Box 188, GREENVILLE, IN 47124.

Where does Greenville Water Utility get its water?

According to EPA's record, Greenville Water Utility uses groundwater bought from Indiana American Water, Edwardsville Water Corporation and Floyds Knobs Water Company, Inc..

Does Greenville Water Utility have any EPA violations?

No health-based violations on EPA record since 2016. The record comes from EPA's SDWIS compliance database.

What is Greenville Water Utility's latest lead result?

The 90th-percentile lead result in Greenville Water Utility's latest lead and copper round, which ended in December 2024, was 1.31 µg/L, below the federal action level of 15 µg/L.

Who do I contact about my Greenville Water Utility water bill?

PurityMap has no verified website for Greenville Water Utility. Its phone number on EPA record is 812-267-2808. Its mailing address on EPA record is P.O. Box 188, GREENVILLE, IN 47124. Your water bill lists the ways to contact your supplier and pay. PurityMap does not take payments.