Change
Water utility · Muhlenberg County · Kentucky

Greenville Utilities Commission

No open health-based violations on EPA record in the last 10 years; latest legal-limit breach in the period starting January 2025.

Serves about 5,649 people (2,256 connections) with surface water from its own intake, and buys water from Muhlenberg Co Water District.

  • PWSID KY0890170
  • EPA registered name: GREENVILLE UTILITIES COMMISSION
  • EPA record checked June 18, 2026
Contact

Contact Greenville Utilities Commission

From EPA's record for KY0890170. PurityMap is independent of Greenville Utilities Commission.

Mailing address
PO BOX 283
GREENVILLE, KY 42345
Directions ↗

Are you this utility? Correct this listing →

EPA compliance record

What EPA's record shows

3 health-based violations in the last 10 years, from EPA's SDWIS compliance database.

  • Total trihalomethanes (TTHM), a by-product of disinfecting water with chlorine, were above the legal limit in the period starting January 2025.
Recent health-based violations for Greenville Utilities Commission (PWSID KY0890170)
PeriodContaminantMeasuredLegal limitEPA status
Jan–Mar 2025Total trihalomethanes (TTHM)0.082 mg/L0.080 mg/LResolved
From January 2024Interim Enhanced Surface Water Treatment Rule1.02 NTU–Resolved
From January 2024Interim Enhanced Surface Water Treatment Rule––Resolved
  • Lead: the 90th-percentile result in the latest lead and copper round (the round ending December 31, 2024) was not detected. The federal action level is 15 µg/L, a trigger for more treatment steps, not a legal limit.
  • Missed or late tests or reports: 2 in 10 years.
  • EPA lists 16 enforcement actions in 10 years; the latest on November 13, 2025.
Lab results EPA required (UCMR 5)

1 of 30 contaminants detected in EPA testing

EPA required this system to test for 30 unregulated and emerging contaminants, from January 2023 to April 2024.

  • Perfluorobutanoic acid (PFBA)Detected, no limit
    No federal limit
    5.3ng/L
Results as a table30 results with limit, status, sample date and source
EPA-required lab results (UCMR 5) for Greenville Utilities Commission (PWSID KY0890170), Kentucky
ContaminantResultLimitStatusSampledSource
Perfluorobutanoic acid (PFBA)5.3 ng/LNo federal or state limit; shown for transparencyDetected, no limit2023-01-23 to 2024-04-24UCMR5 Analytical Results: GREENVILLE UTILITIES COMMISSION (KY0890170)
11-Chloroeicosafluoro-3-oxaundecane-1-sulfonic acid (11Cl-PF3OUdS)< 5 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2023-01-23 to 2024-04-24UCMR5 Analytical Results: GREENVILLE UTILITIES COMMISSION (KY0890170)
1H, 1H, 2H, 2H-perfluorodecane sulfonic acid (8:2 FTS)< 5 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2023-01-23 to 2024-04-24UCMR5 Analytical Results: GREENVILLE UTILITIES COMMISSION (KY0890170)
1H, 1H, 2H, 2H-perfluorohexane sulfonic acid (4:2 FTS)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2023-01-23 to 2024-04-24UCMR5 Analytical Results: GREENVILLE UTILITIES COMMISSION (KY0890170)
1H, 1H, 2H, 2H-perfluorooctane sulfonic acid (6:2 FTS)< 5 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2023-01-23 to 2024-04-24UCMR5 Analytical Results: GREENVILLE UTILITIES COMMISSION (KY0890170)
4,8-Dioxa-3H-perfluorononanoic acid (ADONA)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2023-01-23 to 2024-04-24UCMR5 Analytical Results: GREENVILLE UTILITIES COMMISSION (KY0890170)
9-Chlorohexadecafluoro-3-oxanone-1-sulfonic acid (9Cl-PF3ONS)< 2 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2023-01-23 to 2024-04-24UCMR5 Analytical Results: GREENVILLE UTILITIES COMMISSION (KY0890170)
Hexafluoropropylene oxide dimer acid (HFPO-DA) (GenX chemicals)< 5 ng/L10 ng/L federal MCL (2024)Not detected above the reporting limit2023-01-23 to 2024-04-24UCMR5 Analytical Results: GREENVILLE UTILITIES COMMISSION (KY0890170)
Lithium< 9 µg/L10 µg/L EPA health reference level (screening, not a legal limit)Screening level, not a legal limitNot detected above the reporting limit2023-01-23 to 2023-10-09UCMR5 Analytical Results: GREENVILLE UTILITIES COMMISSION (KY0890170)
N-ethyl perfluorooctanesulfonamidoacetic acid (NEtFOSAA)< 5 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2023-01-23 to 2023-10-09UCMR5 Analytical Results: GREENVILLE UTILITIES COMMISSION (KY0890170)
N-methyl perfluorooctanesulfonamidoacetic acid (NMeFOSAA)< 6 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2023-01-23 to 2023-10-09UCMR5 Analytical Results: GREENVILLE UTILITIES COMMISSION (KY0890170)
Nonafluoro-3,6-dioxaheptanoic acid (NFDHA)< 20 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2023-01-23 to 2024-04-24UCMR5 Analytical Results: GREENVILLE UTILITIES COMMISSION (KY0890170)
Perfluoro (2-ethoxyethane) sulfonic acid (PFEESA)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2023-01-23 to 2024-04-24UCMR5 Analytical Results: GREENVILLE UTILITIES COMMISSION (KY0890170)
Perfluoro-3-methoxypropanoic acid (PFMPA)< 4 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2023-01-23 to 2024-04-24UCMR5 Analytical Results: GREENVILLE UTILITIES COMMISSION (KY0890170)
Perfluoro-4-methoxybutanoic acid (PFMBA)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2023-01-23 to 2024-04-24UCMR5 Analytical Results: GREENVILLE UTILITIES COMMISSION (KY0890170)
Perfluorobutanesulfonic acid (PFBS)< 3 ng/L2,000 ng/L EPA health advisory (screening, not a legal limit)Screening level, not a legal limitNot detected above the reporting limit2023-01-23 to 2024-04-24UCMR5 Analytical Results: GREENVILLE UTILITIES COMMISSION (KY0890170)
Perfluorodecanoic acid (PFDA)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2023-01-23 to 2024-04-24UCMR5 Analytical Results: GREENVILLE UTILITIES COMMISSION (KY0890170)
Perfluorododecanoic acid (PFDoA)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2023-01-23 to 2024-04-24UCMR5 Analytical Results: GREENVILLE UTILITIES COMMISSION (KY0890170)
Perfluoroheptanesulfonic acid (PFHpS)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2023-01-23 to 2024-04-24UCMR5 Analytical Results: GREENVILLE UTILITIES COMMISSION (KY0890170)
Perfluoroheptanoic acid (PFHpA)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2023-01-23 to 2024-04-24UCMR5 Analytical Results: GREENVILLE UTILITIES COMMISSION (KY0890170)
Perfluorohexanesulfonic acid (PFHxS)< 3 ng/L10 ng/L federal MCL (2024)Not detected above the reporting limit2023-01-23 to 2024-04-24UCMR5 Analytical Results: GREENVILLE UTILITIES COMMISSION (KY0890170)
Perfluorohexanoic acid (PFHxA)< 3 ng/L400,000 ng/L Michigan EGLE state MCL (strictest US state)Not detected above the reporting limit2023-01-23 to 2024-04-24UCMR5 Analytical Results: GREENVILLE UTILITIES COMMISSION (KY0890170)
Perfluorononanoic acid (PFNA)< 4 ng/L10 ng/L federal MCL (2024)Not detected above the reporting limit2023-01-23 to 2024-04-24UCMR5 Analytical Results: GREENVILLE UTILITIES COMMISSION (KY0890170)
Perfluorooctanesulfonic acid (PFOS)< 4 ng/L4.0 ng/L federal MCL (2024)Not detected above the reporting limit2023-01-23 to 2024-04-24UCMR5 Analytical Results: GREENVILLE UTILITIES COMMISSION (KY0890170)
Perfluorooctanoic acid (PFOA)< 4 ng/L4.0 ng/L federal MCL (2024)Not detected above the reporting limit2023-01-23 to 2024-04-24UCMR5 Analytical Results: GREENVILLE UTILITIES COMMISSION (KY0890170)
Perfluoropentanesulfonic acid (PFPeS)< 4 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2023-01-23 to 2024-04-24UCMR5 Analytical Results: GREENVILLE UTILITIES COMMISSION (KY0890170)
Perfluoropentanoic acid (PFPeA)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2023-01-23 to 2024-04-24UCMR5 Analytical Results: GREENVILLE UTILITIES COMMISSION (KY0890170)
Perfluorotetradecanoic acid (PFTA)< 8 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2023-01-23 to 2023-10-09UCMR5 Analytical Results: GREENVILLE UTILITIES COMMISSION (KY0890170)
Perfluorotridecanoic acid (PFTrDA)< 7 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2023-01-23 to 2023-10-09UCMR5 Analytical Results: GREENVILLE UTILITIES COMMISSION (KY0890170)
Perfluoroundecanoic acid (PFUnA)< 2 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2023-01-23 to 2024-04-24UCMR5 Analytical Results: GREENVILLE UTILITIES COMMISSION (KY0890170)
Not detected (29)
  • 11-Chloroeicosafluoro-3-oxaundecane-1-sulfonic acid (11Cl-PF3OUdS)
  • 1H, 1H, 2H, 2H-perfluorohexane sulfonic acid (4:2 FTS)
  • 1H, 1H, 2H, 2H-perfluorooctane sulfonic acid (6:2 FTS)
  • 1H, 1H, 2H, 2H-perfluorodecane sulfonic acid (8:2 FTS)
  • 9-Chlorohexadecafluoro-3-oxanone-1-sulfonic acid (9Cl-PF3ONS)
  • 4,8-Dioxa-3H-perfluorononanoic acid (ADONA)
  • Hexafluoropropylene oxide dimer acid (HFPO-DA) (GenX chemicals)
  • N-ethyl perfluorooctanesulfonamidoacetic acid (NEtFOSAA)
  • Nonafluoro-3,6-dioxaheptanoic acid (NFDHA)
  • N-methyl perfluorooctanesulfonamidoacetic acid (NMeFOSAA)
  • Perfluorobutanesulfonic acid (PFBS)
  • Perfluorodecanoic acid (PFDA)
  • Perfluorododecanoic acid (PFDoA)
  • Perfluoro (2-ethoxyethane) sulfonic acid (PFEESA)
  • Perfluoroheptanoic acid (PFHpA)
  • Perfluoroheptanesulfonic acid (PFHpS)
  • Perfluorohexanoic acid (PFHxA)
  • Perfluorohexanesulfonic acid (PFHxS)
  • Perfluoro-4-methoxybutanoic acid (PFMBA)
  • Perfluoro-3-methoxypropanoic acid (PFMPA)
  • Perfluorononanoic acid (PFNA)
  • Perfluorooctanoic acid (PFOA)
  • Perfluorooctanesulfonic acid (PFOS)
  • Perfluoropentanoic acid (PFPeA)
  • Perfluoropentanesulfonic acid (PFPeS)
  • Perfluorotetradecanoic acid (PFTA)
  • Perfluorotridecanoic acid (PFTrDA)
  • Perfluoroundecanoic acid (PFUnA)
  • Lithium
Commercial · test your own tap

The system record stops at your property line

Screening tells you if something is worth a closer look; a lab result is the number you can act on.

As an Amazon Associate, PurityMap earns from qualifying purchases. Affiliate disclosure

  • Screening: quick check, not lab-grade

    Safe Home DIY Lead in Drinking Water Combo Test Kit

    Safe Home (EnviroTestKits)

    Lead, read as one of three ranges: 0–4, 5–15 or 15+ ppb

    Turnaround: 5 minutes

    What it can't tell you: It shows a lead range, not an exact level, and tests nothing else unless you pay extra for the optional lab test.

Questions

About Greenville Utilities Commission

Follow Greenville Utilities Commission

Get PurityMap updates about this water system.

Follow this water →
What is the phone number for Greenville Utilities Commission?

Greenville Utilities Commission's phone number on EPA record is 270-338-2642. Its mailing address is PO BOX 283, GREENVILLE, KY 42345.

Where does Greenville Utilities Commission get its water?

According to EPA's record, Greenville Utilities Commission uses surface water from its own intake, and buys water from Muhlenberg Co Water District.

Does Greenville Utilities Commission have any EPA violations?

EPA's record shows 3 health-based violations for Greenville Utilities Commission in the 10 years to July 9, 2026. No open health-based violations on EPA record in the last 10 years. The latest legal-limit breach on record was in the period starting January 2025. EPA also lists 2 missed or late tests or reports in 10 years. The record comes from EPA's SDWIS compliance database.

What is Greenville Utilities Commission's latest lead result?

Lead was not detected at the 90th percentile of tap samples in Greenville Utilities Commission's latest lead and copper round, which ended in December 2024. The federal action level is 15 µg/L.

Who do I contact about my Greenville Utilities Commission water bill?

PurityMap has no verified website for Greenville Utilities Commission. Its phone number on EPA record is 270-338-2642. Its mailing address on EPA record is PO BOX 283, GREENVILLE, KY 42345. Your water bill lists the ways to contact your supplier and pay. PurityMap does not take payments.