Change
Water utility · Knott County · Kentucky

Knott Co Water & Sewer District

No open health-based violations on EPA record in the last 10 years; latest legal-limit breach in the period starting April 2018.

Serves about 7,056 people (3,190 connections) with surface water from its own intake, and buys water from Hazard Water Department, Southern Water & Sewer District and Hindman Mun Water Works.

  • PWSID KY0600062
  • EPA registered name: KNOTT CO WATER & SEWER DISTRICT
  • EPA record checked June 18, 2026
Contact

Contact Knott Co Water & Sewer District

From EPA's record for KY0600062. PurityMap is independent of Knott Co Water & Sewer District.

Mailing address
7777 BIG BRANCH RD.
VICCO, KY 41773
Directions ↗

Are you this utility? Correct this listing →

EPA compliance record

What EPA's record shows

2 health-based violations in the last 10 years, from EPA's SDWIS compliance database.

  • Haloacetic acids (HAA5), a by-product of disinfecting water with chlorine, were above the legal limit in 2 quarters since January 2018.
Recent health-based violations for Knott Co Water & Sewer District (PWSID KY0600062)
PeriodContaminantMeasuredLegal limitEPA status
Apr–Jun 2018Haloacetic acids (HAA5)0.067 mg/L0.060 mg/LResolved
Jan–Mar 2018Haloacetic acids (HAA5)0.062 mg/L0.060 mg/LResolved
  • Lead: the 90th-percentile result in the latest lead and copper round (the round ending December 31, 2024) was not detected. The federal action level is 15 µg/L, a trigger for more treatment steps, not a legal limit.
  • Missed or late tests or reports: 1 in 10 years.
  • EPA lists 10 enforcement actions in 10 years; the latest on May 29, 2019.
Lab results EPA required (UCMR 5)

None of the contaminants were detected in EPA testing

EPA required this system to test for 30 unregulated and emerging contaminants, from March 2025 to September 2025.

Results as a table30 results with limit, status, sample date and source
EPA-required lab results (UCMR 5) for Knott Co Water & Sewer District (PWSID KY0600062), Kentucky
ContaminantResultLimitStatusSampledSource
11-Chloroeicosafluoro-3-oxaundecane-1-sulfonic acid (11Cl-PF3OUdS)< 5 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2025-03-05 to 2025-09-10UCMR5 Analytical Results: KNOTT CO WATER & SEWER DISTRICT (KY0600062)
1H, 1H, 2H, 2H-perfluorodecane sulfonic acid (8:2 FTS)< 5 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2025-03-05 to 2025-09-10UCMR5 Analytical Results: KNOTT CO WATER & SEWER DISTRICT (KY0600062)
1H, 1H, 2H, 2H-perfluorohexane sulfonic acid (4:2 FTS)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2025-03-05 to 2025-09-10UCMR5 Analytical Results: KNOTT CO WATER & SEWER DISTRICT (KY0600062)
1H, 1H, 2H, 2H-perfluorooctane sulfonic acid (6:2 FTS)< 5 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2025-03-05 to 2025-09-10UCMR5 Analytical Results: KNOTT CO WATER & SEWER DISTRICT (KY0600062)
4,8-Dioxa-3H-perfluorononanoic acid (ADONA)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2025-03-05 to 2025-09-10UCMR5 Analytical Results: KNOTT CO WATER & SEWER DISTRICT (KY0600062)
9-Chlorohexadecafluoro-3-oxanone-1-sulfonic acid (9Cl-PF3ONS)< 2 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2025-03-05 to 2025-09-10UCMR5 Analytical Results: KNOTT CO WATER & SEWER DISTRICT (KY0600062)
Hexafluoropropylene oxide dimer acid (HFPO-DA) (GenX chemicals)< 5 ng/L10 ng/L federal MCL (2024)Not detected above the reporting limit2025-03-05 to 2025-09-10UCMR5 Analytical Results: KNOTT CO WATER & SEWER DISTRICT (KY0600062)
Lithium< 9 µg/L10 µg/L EPA health reference level (screening, not a legal limit)Screening level, not a legal limitNot detected above the reporting limit2025-03-05 to 2025-09-10UCMR5 Analytical Results: KNOTT CO WATER & SEWER DISTRICT (KY0600062)
N-ethyl perfluorooctanesulfonamidoacetic acid (NEtFOSAA)< 5 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2025-03-05 to 2025-09-10UCMR5 Analytical Results: KNOTT CO WATER & SEWER DISTRICT (KY0600062)
N-methyl perfluorooctanesulfonamidoacetic acid (NMeFOSAA)< 6 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2025-03-05 to 2025-09-10UCMR5 Analytical Results: KNOTT CO WATER & SEWER DISTRICT (KY0600062)
Nonafluoro-3,6-dioxaheptanoic acid (NFDHA)< 20 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2025-03-05 to 2025-09-10UCMR5 Analytical Results: KNOTT CO WATER & SEWER DISTRICT (KY0600062)
Perfluoro (2-ethoxyethane) sulfonic acid (PFEESA)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2025-03-05 to 2025-09-10UCMR5 Analytical Results: KNOTT CO WATER & SEWER DISTRICT (KY0600062)
Perfluoro-3-methoxypropanoic acid (PFMPA)< 4 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2025-03-05 to 2025-09-10UCMR5 Analytical Results: KNOTT CO WATER & SEWER DISTRICT (KY0600062)
Perfluoro-4-methoxybutanoic acid (PFMBA)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2025-03-05 to 2025-09-10UCMR5 Analytical Results: KNOTT CO WATER & SEWER DISTRICT (KY0600062)
Perfluorobutanesulfonic acid (PFBS)< 3 ng/L2,000 ng/L EPA health advisory (screening, not a legal limit)Screening level, not a legal limitNot detected above the reporting limit2025-03-05 to 2025-09-10UCMR5 Analytical Results: KNOTT CO WATER & SEWER DISTRICT (KY0600062)
Perfluorobutanoic acid (PFBA)< 5 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2025-03-05 to 2025-09-10UCMR5 Analytical Results: KNOTT CO WATER & SEWER DISTRICT (KY0600062)
Perfluorodecanoic acid (PFDA)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2025-03-05 to 2025-09-10UCMR5 Analytical Results: KNOTT CO WATER & SEWER DISTRICT (KY0600062)
Perfluorododecanoic acid (PFDoA)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2025-03-05 to 2025-09-10UCMR5 Analytical Results: KNOTT CO WATER & SEWER DISTRICT (KY0600062)
Perfluoroheptanesulfonic acid (PFHpS)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2025-03-05 to 2025-09-10UCMR5 Analytical Results: KNOTT CO WATER & SEWER DISTRICT (KY0600062)
Perfluoroheptanoic acid (PFHpA)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2025-03-05 to 2025-09-10UCMR5 Analytical Results: KNOTT CO WATER & SEWER DISTRICT (KY0600062)
Perfluorohexanesulfonic acid (PFHxS)< 3 ng/L10 ng/L federal MCL (2024)Not detected above the reporting limit2025-03-05 to 2025-09-10UCMR5 Analytical Results: KNOTT CO WATER & SEWER DISTRICT (KY0600062)
Perfluorohexanoic acid (PFHxA)< 3 ng/L400,000 ng/L Michigan EGLE state MCL (strictest US state)Not detected above the reporting limit2025-03-05 to 2025-09-10UCMR5 Analytical Results: KNOTT CO WATER & SEWER DISTRICT (KY0600062)
Perfluorononanoic acid (PFNA)< 4 ng/L10 ng/L federal MCL (2024)Not detected above the reporting limit2025-03-05 to 2025-09-10UCMR5 Analytical Results: KNOTT CO WATER & SEWER DISTRICT (KY0600062)
Perfluorooctanesulfonic acid (PFOS)< 4 ng/L4.0 ng/L federal MCL (2024)Not detected above the reporting limit2025-03-05 to 2025-09-10UCMR5 Analytical Results: KNOTT CO WATER & SEWER DISTRICT (KY0600062)
Perfluorooctanoic acid (PFOA)< 4 ng/L4.0 ng/L federal MCL (2024)Not detected above the reporting limit2025-03-05 to 2025-09-10UCMR5 Analytical Results: KNOTT CO WATER & SEWER DISTRICT (KY0600062)
Perfluoropentanesulfonic acid (PFPeS)< 4 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2025-03-05 to 2025-09-10UCMR5 Analytical Results: KNOTT CO WATER & SEWER DISTRICT (KY0600062)
Perfluoropentanoic acid (PFPeA)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2025-03-05 to 2025-09-10UCMR5 Analytical Results: KNOTT CO WATER & SEWER DISTRICT (KY0600062)
Perfluorotetradecanoic acid (PFTA)< 8 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2025-03-05 to 2025-09-10UCMR5 Analytical Results: KNOTT CO WATER & SEWER DISTRICT (KY0600062)
Perfluorotridecanoic acid (PFTrDA)< 7 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2025-03-05 to 2025-09-10UCMR5 Analytical Results: KNOTT CO WATER & SEWER DISTRICT (KY0600062)
Perfluoroundecanoic acid (PFUnA)< 2 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2025-03-05 to 2025-09-10UCMR5 Analytical Results: KNOTT CO WATER & SEWER DISTRICT (KY0600062)
Not detected (30)
  • 11-Chloroeicosafluoro-3-oxaundecane-1-sulfonic acid (11Cl-PF3OUdS)
  • 1H, 1H, 2H, 2H-perfluorohexane sulfonic acid (4:2 FTS)
  • 1H, 1H, 2H, 2H-perfluorooctane sulfonic acid (6:2 FTS)
  • 1H, 1H, 2H, 2H-perfluorodecane sulfonic acid (8:2 FTS)
  • 9-Chlorohexadecafluoro-3-oxanone-1-sulfonic acid (9Cl-PF3ONS)
  • 4,8-Dioxa-3H-perfluorononanoic acid (ADONA)
  • Hexafluoropropylene oxide dimer acid (HFPO-DA) (GenX chemicals)
  • N-ethyl perfluorooctanesulfonamidoacetic acid (NEtFOSAA)
  • Nonafluoro-3,6-dioxaheptanoic acid (NFDHA)
  • N-methyl perfluorooctanesulfonamidoacetic acid (NMeFOSAA)
  • Perfluorobutanoic acid (PFBA)
  • Perfluorobutanesulfonic acid (PFBS)
  • Perfluorodecanoic acid (PFDA)
  • Perfluorododecanoic acid (PFDoA)
  • Perfluoro (2-ethoxyethane) sulfonic acid (PFEESA)
  • Perfluoroheptanoic acid (PFHpA)
  • Perfluoroheptanesulfonic acid (PFHpS)
  • Perfluorohexanoic acid (PFHxA)
  • Perfluorohexanesulfonic acid (PFHxS)
  • Perfluoro-4-methoxybutanoic acid (PFMBA)
  • Perfluoro-3-methoxypropanoic acid (PFMPA)
  • Perfluorononanoic acid (PFNA)
  • Perfluorooctanoic acid (PFOA)
  • Perfluorooctanesulfonic acid (PFOS)
  • Perfluoropentanoic acid (PFPeA)
  • Perfluoropentanesulfonic acid (PFPeS)
  • Perfluorotetradecanoic acid (PFTA)
  • Perfluorotridecanoic acid (PFTrDA)
  • Perfluoroundecanoic acid (PFUnA)
  • Lithium
Commercial · test your own tap

The system record stops at your property line

Screening tells you if something is worth a closer look; a lab result is the number you can act on.

As an Amazon Associate, PurityMap earns from qualifying purchases. Affiliate disclosure

  • Screening: quick check, not lab-grade

    Safe Home DIY Lead in Drinking Water Combo Test Kit

    Safe Home (EnviroTestKits)

    Lead, read as one of three ranges: 0–4, 5–15 or 15+ ppb

    Turnaround: 5 minutes

    What it can't tell you: It shows a lead range, not an exact level, and tests nothing else unless you pay extra for the optional lab test.

Questions

About Knott Co Water & Sewer District

Follow Knott Co Water & Sewer District

Get PurityMap updates about this water system.

Follow this water →
What is the phone number for Knott Co Water & Sewer District?

Knott Co Water & Sewer District's phone number on EPA record is 606-642-3582. Its mailing address is 7777 BIG BRANCH RD., VICCO, KY 41773.

Where does Knott Co Water & Sewer District get its water?

According to EPA's record, Knott Co Water & Sewer District uses surface water from its own intake, and buys water from Hazard Water Department, Southern Water & Sewer District and Hindman Mun Water Works.

Does Knott Co Water & Sewer District have any EPA violations?

EPA's record shows 2 health-based violations for Knott Co Water & Sewer District in the 10 years to July 9, 2026. No open health-based violations on EPA record in the last 10 years. The latest legal-limit breach on record was in the period starting April 2018. EPA also lists 1 missed or late test or report in 10 years. The record comes from EPA's SDWIS compliance database.

What is Knott Co Water & Sewer District's latest lead result?

Lead was not detected at the 90th percentile of tap samples in Knott Co Water & Sewer District's latest lead and copper round, which ended in December 2024. The federal action level is 15 µg/L.

Who do I contact about my Knott Co Water & Sewer District water bill?

PurityMap has no verified website for Knott Co Water & Sewer District. Its phone number on EPA record is 606-642-3582. Its mailing address on EPA record is 7777 BIG BRANCH RD., VICCO, KY 41773. Your water bill lists the ways to contact your supplier and pay. PurityMap does not take payments.