No health-based violations on EPA record since 2016.

Serves about 29,823 people (12,299 connections) with surface water from its own intake.

  • PWSID KY0250473
  • EPA registered name: WINCHESTER MUNICIPAL UTILITIES
  • EPA record checked June 18, 2026
Contact

Contact Winchester Municipal Utilities

From EPA's record for KY0250473. PurityMap is independent of Winchester Municipal Utilities.

Mailing address
PO BOX 4177, 7055 BOONESBORO RD
WINCHESTER, KY 40391
Directions ↗

Are you this utility? Correct this listing →

EPA compliance record

What EPA's record shows

No health-based violations in the last 10 years, from EPA's SDWIS compliance database.

  • Lead: the 90th-percentile result in the latest lead and copper round (the round ending December 31, 2025) was not detected. The federal action level is 15 µg/L, a trigger for more treatment steps, not a legal limit.
  • Missed or late tests or reports: none in 10 years.
  • EPA lists 4 enforcement actions in 10 years; the latest on May 1, 2017.
Lab results EPA required (UCMR 5)

None of the contaminants were detected in EPA testing

EPA required this system to test for 30 unregulated and emerging contaminants, from February 2024 to November 2024.

Results as a table30 results with limit, status, sample date and source
EPA-required lab results (UCMR 5) for Winchester Municipal Utilities (PWSID KY0250473), Kentucky
ContaminantResultLimitStatusSampledSource
11-Chloroeicosafluoro-3-oxaundecane-1-sulfonic acid (11Cl-PF3OUdS)< 5 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-02-07 to 2024-11-05UCMR5 Analytical Results: WINCHESTER MUNICIPAL UTILITIES (KY0250473)
1H, 1H, 2H, 2H-perfluorodecane sulfonic acid (8:2 FTS)< 5 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-02-07 to 2024-11-05UCMR5 Analytical Results: WINCHESTER MUNICIPAL UTILITIES (KY0250473)
1H, 1H, 2H, 2H-perfluorohexane sulfonic acid (4:2 FTS)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-02-07 to 2024-11-05UCMR5 Analytical Results: WINCHESTER MUNICIPAL UTILITIES (KY0250473)
1H, 1H, 2H, 2H-perfluorooctane sulfonic acid (6:2 FTS)< 5 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-02-07 to 2024-11-05UCMR5 Analytical Results: WINCHESTER MUNICIPAL UTILITIES (KY0250473)
4,8-Dioxa-3H-perfluorononanoic acid (ADONA)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-02-07 to 2024-11-05UCMR5 Analytical Results: WINCHESTER MUNICIPAL UTILITIES (KY0250473)
9-Chlorohexadecafluoro-3-oxanone-1-sulfonic acid (9Cl-PF3ONS)< 2 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-02-07 to 2024-11-05UCMR5 Analytical Results: WINCHESTER MUNICIPAL UTILITIES (KY0250473)
Hexafluoropropylene oxide dimer acid (HFPO-DA) (GenX chemicals)< 5 ng/L10 ng/L federal MCL (2024)Not detected above the reporting limit2024-02-07 to 2024-11-05UCMR5 Analytical Results: WINCHESTER MUNICIPAL UTILITIES (KY0250473)
Lithium< 9 µg/L10 µg/L EPA health reference level (screening, not a legal limit)Screening level, not a legal limitNot detected above the reporting limit2024-02-07 to 2024-11-05UCMR5 Analytical Results: WINCHESTER MUNICIPAL UTILITIES (KY0250473)
N-ethyl perfluorooctanesulfonamidoacetic acid (NEtFOSAA)< 5 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-02-07 to 2024-11-05UCMR5 Analytical Results: WINCHESTER MUNICIPAL UTILITIES (KY0250473)
N-methyl perfluorooctanesulfonamidoacetic acid (NMeFOSAA)< 6 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-02-07 to 2024-11-05UCMR5 Analytical Results: WINCHESTER MUNICIPAL UTILITIES (KY0250473)
Nonafluoro-3,6-dioxaheptanoic acid (NFDHA)< 20 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-02-07 to 2024-11-05UCMR5 Analytical Results: WINCHESTER MUNICIPAL UTILITIES (KY0250473)
Perfluoro (2-ethoxyethane) sulfonic acid (PFEESA)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-02-07 to 2024-11-05UCMR5 Analytical Results: WINCHESTER MUNICIPAL UTILITIES (KY0250473)
Perfluoro-3-methoxypropanoic acid (PFMPA)< 4 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-02-07 to 2024-11-05UCMR5 Analytical Results: WINCHESTER MUNICIPAL UTILITIES (KY0250473)
Perfluoro-4-methoxybutanoic acid (PFMBA)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-02-07 to 2024-11-05UCMR5 Analytical Results: WINCHESTER MUNICIPAL UTILITIES (KY0250473)
Perfluorobutanesulfonic acid (PFBS)< 3 ng/L2,000 ng/L EPA health advisory (screening, not a legal limit)Screening level, not a legal limitNot detected above the reporting limit2024-02-07 to 2024-11-05UCMR5 Analytical Results: WINCHESTER MUNICIPAL UTILITIES (KY0250473)
Perfluorobutanoic acid (PFBA)< 5 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-02-07 to 2024-11-05UCMR5 Analytical Results: WINCHESTER MUNICIPAL UTILITIES (KY0250473)
Perfluorodecanoic acid (PFDA)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-02-07 to 2024-11-05UCMR5 Analytical Results: WINCHESTER MUNICIPAL UTILITIES (KY0250473)
Perfluorododecanoic acid (PFDoA)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-02-07 to 2024-11-05UCMR5 Analytical Results: WINCHESTER MUNICIPAL UTILITIES (KY0250473)
Perfluoroheptanesulfonic acid (PFHpS)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-02-07 to 2024-11-05UCMR5 Analytical Results: WINCHESTER MUNICIPAL UTILITIES (KY0250473)
Perfluoroheptanoic acid (PFHpA)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-02-07 to 2024-11-05UCMR5 Analytical Results: WINCHESTER MUNICIPAL UTILITIES (KY0250473)
Perfluorohexanesulfonic acid (PFHxS)< 3 ng/L10 ng/L federal MCL (2024)Not detected above the reporting limit2024-02-07 to 2024-11-05UCMR5 Analytical Results: WINCHESTER MUNICIPAL UTILITIES (KY0250473)
Perfluorohexanoic acid (PFHxA)< 3 ng/L400,000 ng/L Michigan EGLE state MCL (strictest US state)Not detected above the reporting limit2024-02-07 to 2024-11-05UCMR5 Analytical Results: WINCHESTER MUNICIPAL UTILITIES (KY0250473)
Perfluorononanoic acid (PFNA)< 4 ng/L10 ng/L federal MCL (2024)Not detected above the reporting limit2024-02-07 to 2024-11-05UCMR5 Analytical Results: WINCHESTER MUNICIPAL UTILITIES (KY0250473)
Perfluorooctanesulfonic acid (PFOS)< 4 ng/L4.0 ng/L federal MCL (2024)Not detected above the reporting limit2024-02-07 to 2024-11-05UCMR5 Analytical Results: WINCHESTER MUNICIPAL UTILITIES (KY0250473)
Perfluorooctanoic acid (PFOA)< 4 ng/L4.0 ng/L federal MCL (2024)Not detected above the reporting limit2024-02-07 to 2024-11-05UCMR5 Analytical Results: WINCHESTER MUNICIPAL UTILITIES (KY0250473)
Perfluoropentanesulfonic acid (PFPeS)< 4 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-02-07 to 2024-11-05UCMR5 Analytical Results: WINCHESTER MUNICIPAL UTILITIES (KY0250473)
Perfluoropentanoic acid (PFPeA)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-02-07 to 2024-11-05UCMR5 Analytical Results: WINCHESTER MUNICIPAL UTILITIES (KY0250473)
Perfluorotetradecanoic acid (PFTA)< 8 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-02-07 to 2024-11-05UCMR5 Analytical Results: WINCHESTER MUNICIPAL UTILITIES (KY0250473)
Perfluorotridecanoic acid (PFTrDA)< 7 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-02-07 to 2024-11-05UCMR5 Analytical Results: WINCHESTER MUNICIPAL UTILITIES (KY0250473)
Perfluoroundecanoic acid (PFUnA)< 2 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-02-07 to 2024-11-05UCMR5 Analytical Results: WINCHESTER MUNICIPAL UTILITIES (KY0250473)
Not detected (30)
  • 11-Chloroeicosafluoro-3-oxaundecane-1-sulfonic acid (11Cl-PF3OUdS)
  • 1H, 1H, 2H, 2H-perfluorohexane sulfonic acid (4:2 FTS)
  • 1H, 1H, 2H, 2H-perfluorooctane sulfonic acid (6:2 FTS)
  • 1H, 1H, 2H, 2H-perfluorodecane sulfonic acid (8:2 FTS)
  • 9-Chlorohexadecafluoro-3-oxanone-1-sulfonic acid (9Cl-PF3ONS)
  • 4,8-Dioxa-3H-perfluorononanoic acid (ADONA)
  • Hexafluoropropylene oxide dimer acid (HFPO-DA) (GenX chemicals)
  • N-ethyl perfluorooctanesulfonamidoacetic acid (NEtFOSAA)
  • Nonafluoro-3,6-dioxaheptanoic acid (NFDHA)
  • N-methyl perfluorooctanesulfonamidoacetic acid (NMeFOSAA)
  • Perfluorobutanoic acid (PFBA)
  • Perfluorobutanesulfonic acid (PFBS)
  • Perfluorodecanoic acid (PFDA)
  • Perfluorododecanoic acid (PFDoA)
  • Perfluoro (2-ethoxyethane) sulfonic acid (PFEESA)
  • Perfluoroheptanoic acid (PFHpA)
  • Perfluoroheptanesulfonic acid (PFHpS)
  • Perfluorohexanoic acid (PFHxA)
  • Perfluorohexanesulfonic acid (PFHxS)
  • Perfluoro-4-methoxybutanoic acid (PFMBA)
  • Perfluoro-3-methoxypropanoic acid (PFMPA)
  • Perfluorononanoic acid (PFNA)
  • Perfluorooctanoic acid (PFOA)
  • Perfluorooctanesulfonic acid (PFOS)
  • Perfluoropentanoic acid (PFPeA)
  • Perfluoropentanesulfonic acid (PFPeS)
  • Perfluorotetradecanoic acid (PFTA)
  • Perfluorotridecanoic acid (PFTrDA)
  • Perfluoroundecanoic acid (PFUnA)
  • Lithium
Commercial · test your own tap

The system record stops at your property line

Screening tells you if something is worth a closer look; a lab result is the number you can act on.

As an Amazon Associate, PurityMap earns from qualifying purchases. Affiliate disclosure

  • Screening: quick check, not lab-grade

    Safe Home DIY Lead in Drinking Water Combo Test Kit

    Safe Home (EnviroTestKits)

    Lead, read as one of three ranges: 0–4, 5–15 or 15+ ppb

    Turnaround: 5 minutes

    What it can't tell you: It shows a lead range, not an exact level, and tests nothing else unless you pay extra for the optional lab test.

Questions

About Winchester Municipal Utilities

Follow Winchester Municipal Utilities

Get PurityMap updates about this water system.

Follow this water →
What is the phone number for Winchester Municipal Utilities?

Winchester Municipal Utilities's phone number on EPA record is 859-744-5434. Its mailing address is PO BOX 4177, 7055 BOONESBORO RD, WINCHESTER, KY 40391.

Where does Winchester Municipal Utilities get its water?

According to EPA's record, Winchester Municipal Utilities uses surface water from its own intake.

Does Winchester Municipal Utilities have any EPA violations?

No health-based violations on EPA record since 2016. The record comes from EPA's SDWIS compliance database.

What is Winchester Municipal Utilities's latest lead result?

Lead was not detected at the 90th percentile of tap samples in Winchester Municipal Utilities's latest lead and copper round, which ended in December 2025. The federal action level is 15 µg/L.

Who do I contact about my Winchester Municipal Utilities water bill?

PurityMap has no verified website for Winchester Municipal Utilities. Its phone number on EPA record is 859-744-5434. Its mailing address on EPA record is PO BOX 4177, 7055 BOONESBORO RD, WINCHESTER, KY 40391. Your water bill lists the ways to contact your supplier and pay. PurityMap does not take payments.