Change
Water utility · St. Mary Parish · Louisiana

St Mary Water & Sewer Comm #3

No open health-based violations on EPA record in the last 10 years; latest legal-limit breach in the period starting January 2025.

Serves about 7,828 people (1,957 connections) with surface water from its own intake.

  • PWSID LA1101010
  • EPA registered name: ST MARY WATER & SEWER COMM #3
  • EPA record checked June 23, 2026
Contact

Contact St Mary Water & Sewer Comm #3

From EPA's record for LA1101010. PurityMap is independent of St Mary Water & Sewer Comm #3.

Mailing address
P.O. BOX 119
CENTERVILLE, LA 70522
Directions ↗

Are you this utility? Correct this listing →

EPA compliance record

What EPA's record shows

3 health-based violations in the last 10 years, from EPA's SDWIS compliance database.

  • Haloacetic acids (HAA5), a by-product of disinfecting water with chlorine, were above the legal limit in 2 quarters since July 2017.
  • Total trihalomethanes (TTHM), a by-product of disinfecting water with chlorine, were above the legal limit in the period starting July 2017.
Recent health-based violations for St Mary Water & Sewer Comm #3 (PWSID LA1101010)
PeriodContaminantMeasuredLegal limitEPA status
Jan–Mar 2025Haloacetic acids (HAA5)0.064 mg/L0.060 mg/LResolved
Jul–Sep 2017Haloacetic acids (HAA5)66 µg/L0.060 mg/LResolved
Jul–Sep 2017Total trihalomethanes (TTHM)83 µg/L0.080 mg/LResolved
  • Lead: the 90th-percentile result in the latest lead and copper round (the round ending December 31, 2025) was 3.3 µg/L. The federal action level is 15 µg/L, a trigger for more treatment steps, not a legal limit.
  • Missed or late tests or reports: 4 in 10 years.
  • EPA lists 19 enforcement actions in 10 years; the latest on April 7, 2025.
Lab results EPA required (UCMR 5)

2 of 30 contaminants detected in EPA testing

EPA required this system to test for 30 unregulated and emerging contaminants, from February 2024 to December 2024.

  • LithiumAbove the referenced health-based guidance value
    10 µg/L EPA health reference level · not a legal limit
    11µg/L
  • Perfluorobutanoic acid (PFBA)Detected, no limit
    No federal limit
    5.4ng/L
Results as a table30 results with limit, status, sample date and source
EPA-required lab results (UCMR 5) for St Mary Water & Sewer Comm #3 (PWSID LA1101010), Louisiana
ContaminantResultLimitStatusSampledSource
Lithium11 µg/L10 µg/L EPA health reference level (screening, not a legal limit)Screening level, not a legal limitAbove the referenced health-based guidance value2024-02-06 to 2024-11-13UCMR5 Analytical Results: ST MARY WATER & SEWER COMM #3 (LA1101010)
Perfluorobutanoic acid (PFBA)5.4 ng/LNo federal or state limit; shown for transparencyDetected, no limit2024-02-06 to 2024-12-16UCMR5 Analytical Results: ST MARY WATER & SEWER COMM #3 (LA1101010)
11-Chloroeicosafluoro-3-oxaundecane-1-sulfonic acid (11Cl-PF3OUdS)< 5 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-02-06 to 2024-12-16UCMR5 Analytical Results: ST MARY WATER & SEWER COMM #3 (LA1101010)
1H, 1H, 2H, 2H-perfluorodecane sulfonic acid (8:2 FTS)< 5 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-02-06 to 2024-12-16UCMR5 Analytical Results: ST MARY WATER & SEWER COMM #3 (LA1101010)
1H, 1H, 2H, 2H-perfluorohexane sulfonic acid (4:2 FTS)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-02-06 to 2024-12-16UCMR5 Analytical Results: ST MARY WATER & SEWER COMM #3 (LA1101010)
1H, 1H, 2H, 2H-perfluorooctane sulfonic acid (6:2 FTS)< 5 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-02-06 to 2024-12-16UCMR5 Analytical Results: ST MARY WATER & SEWER COMM #3 (LA1101010)
4,8-Dioxa-3H-perfluorononanoic acid (ADONA)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-02-06 to 2024-12-16UCMR5 Analytical Results: ST MARY WATER & SEWER COMM #3 (LA1101010)
9-Chlorohexadecafluoro-3-oxanone-1-sulfonic acid (9Cl-PF3ONS)< 2 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-02-06 to 2024-12-16UCMR5 Analytical Results: ST MARY WATER & SEWER COMM #3 (LA1101010)
Hexafluoropropylene oxide dimer acid (HFPO-DA) (GenX chemicals)< 5 ng/L10 ng/L federal MCL (2024)Not detected above the reporting limit2024-02-06 to 2024-12-16UCMR5 Analytical Results: ST MARY WATER & SEWER COMM #3 (LA1101010)
N-ethyl perfluorooctanesulfonamidoacetic acid (NEtFOSAA)< 5 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-02-06 to 2024-11-13UCMR5 Analytical Results: ST MARY WATER & SEWER COMM #3 (LA1101010)
N-methyl perfluorooctanesulfonamidoacetic acid (NMeFOSAA)< 6 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-02-06 to 2024-11-13UCMR5 Analytical Results: ST MARY WATER & SEWER COMM #3 (LA1101010)
Nonafluoro-3,6-dioxaheptanoic acid (NFDHA)< 20 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-02-06 to 2024-12-16UCMR5 Analytical Results: ST MARY WATER & SEWER COMM #3 (LA1101010)
Perfluoro (2-ethoxyethane) sulfonic acid (PFEESA)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-02-06 to 2024-12-16UCMR5 Analytical Results: ST MARY WATER & SEWER COMM #3 (LA1101010)
Perfluoro-3-methoxypropanoic acid (PFMPA)< 4 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-02-06 to 2024-12-16UCMR5 Analytical Results: ST MARY WATER & SEWER COMM #3 (LA1101010)
Perfluoro-4-methoxybutanoic acid (PFMBA)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-02-06 to 2024-12-16UCMR5 Analytical Results: ST MARY WATER & SEWER COMM #3 (LA1101010)
Perfluorobutanesulfonic acid (PFBS)< 3 ng/L2,000 ng/L EPA health advisory (screening, not a legal limit)Screening level, not a legal limitNot detected above the reporting limit2024-02-06 to 2024-12-16UCMR5 Analytical Results: ST MARY WATER & SEWER COMM #3 (LA1101010)
Perfluorodecanoic acid (PFDA)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-02-06 to 2024-12-16UCMR5 Analytical Results: ST MARY WATER & SEWER COMM #3 (LA1101010)
Perfluorododecanoic acid (PFDoA)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-02-06 to 2024-12-16UCMR5 Analytical Results: ST MARY WATER & SEWER COMM #3 (LA1101010)
Perfluoroheptanesulfonic acid (PFHpS)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-02-06 to 2024-12-16UCMR5 Analytical Results: ST MARY WATER & SEWER COMM #3 (LA1101010)
Perfluoroheptanoic acid (PFHpA)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-02-06 to 2024-12-16UCMR5 Analytical Results: ST MARY WATER & SEWER COMM #3 (LA1101010)
Perfluorohexanesulfonic acid (PFHxS)< 3 ng/L10 ng/L federal MCL (2024)Not detected above the reporting limit2024-02-06 to 2024-12-16UCMR5 Analytical Results: ST MARY WATER & SEWER COMM #3 (LA1101010)
Perfluorohexanoic acid (PFHxA)< 3 ng/L400,000 ng/L Michigan EGLE state MCL (strictest US state)Not detected above the reporting limit2024-02-06 to 2024-12-16UCMR5 Analytical Results: ST MARY WATER & SEWER COMM #3 (LA1101010)
Perfluorononanoic acid (PFNA)< 4 ng/L10 ng/L federal MCL (2024)Not detected above the reporting limit2024-02-06 to 2024-12-16UCMR5 Analytical Results: ST MARY WATER & SEWER COMM #3 (LA1101010)
Perfluorooctanesulfonic acid (PFOS)< 4 ng/L4.0 ng/L federal MCL (2024)Not detected above the reporting limit2024-02-06 to 2024-12-16UCMR5 Analytical Results: ST MARY WATER & SEWER COMM #3 (LA1101010)
Perfluorooctanoic acid (PFOA)< 4 ng/L4.0 ng/L federal MCL (2024)Not detected above the reporting limit2024-02-06 to 2024-12-16UCMR5 Analytical Results: ST MARY WATER & SEWER COMM #3 (LA1101010)
Perfluoropentanesulfonic acid (PFPeS)< 4 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-02-06 to 2024-12-16UCMR5 Analytical Results: ST MARY WATER & SEWER COMM #3 (LA1101010)
Perfluoropentanoic acid (PFPeA)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-02-06 to 2024-12-16UCMR5 Analytical Results: ST MARY WATER & SEWER COMM #3 (LA1101010)
Perfluorotetradecanoic acid (PFTA)< 8 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-02-06 to 2024-11-13UCMR5 Analytical Results: ST MARY WATER & SEWER COMM #3 (LA1101010)
Perfluorotridecanoic acid (PFTrDA)< 7 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-02-06 to 2024-11-13UCMR5 Analytical Results: ST MARY WATER & SEWER COMM #3 (LA1101010)
Perfluoroundecanoic acid (PFUnA)< 2 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-02-06 to 2024-12-16UCMR5 Analytical Results: ST MARY WATER & SEWER COMM #3 (LA1101010)
Not detected (28)
  • 11-Chloroeicosafluoro-3-oxaundecane-1-sulfonic acid (11Cl-PF3OUdS)
  • 1H, 1H, 2H, 2H-perfluorohexane sulfonic acid (4:2 FTS)
  • 1H, 1H, 2H, 2H-perfluorooctane sulfonic acid (6:2 FTS)
  • 1H, 1H, 2H, 2H-perfluorodecane sulfonic acid (8:2 FTS)
  • 9-Chlorohexadecafluoro-3-oxanone-1-sulfonic acid (9Cl-PF3ONS)
  • 4,8-Dioxa-3H-perfluorononanoic acid (ADONA)
  • Hexafluoropropylene oxide dimer acid (HFPO-DA) (GenX chemicals)
  • N-ethyl perfluorooctanesulfonamidoacetic acid (NEtFOSAA)
  • Nonafluoro-3,6-dioxaheptanoic acid (NFDHA)
  • N-methyl perfluorooctanesulfonamidoacetic acid (NMeFOSAA)
  • Perfluorobutanesulfonic acid (PFBS)
  • Perfluorodecanoic acid (PFDA)
  • Perfluorododecanoic acid (PFDoA)
  • Perfluoro (2-ethoxyethane) sulfonic acid (PFEESA)
  • Perfluoroheptanoic acid (PFHpA)
  • Perfluoroheptanesulfonic acid (PFHpS)
  • Perfluorohexanoic acid (PFHxA)
  • Perfluorohexanesulfonic acid (PFHxS)
  • Perfluoro-4-methoxybutanoic acid (PFMBA)
  • Perfluoro-3-methoxypropanoic acid (PFMPA)
  • Perfluorononanoic acid (PFNA)
  • Perfluorooctanoic acid (PFOA)
  • Perfluorooctanesulfonic acid (PFOS)
  • Perfluoropentanoic acid (PFPeA)
  • Perfluoropentanesulfonic acid (PFPeS)
  • Perfluorotetradecanoic acid (PFTA)
  • Perfluorotridecanoic acid (PFTrDA)
  • Perfluoroundecanoic acid (PFUnA)
Commercial · test your own tap

The system record stops at your property line

Screening tells you if something is worth a closer look; a lab result is the number you can act on.

As an Amazon Associate, PurityMap earns from qualifying purchases. Affiliate disclosure

  • Screening: quick check, not lab-grade

    Safe Home DIY Lead in Drinking Water Combo Test Kit

    Safe Home (EnviroTestKits)

    Lead, read as one of three ranges: 0–4, 5–15 or 15+ ppb

    Turnaround: 5 minutes

    What it can't tell you: It shows a lead range, not an exact level, and tests nothing else unless you pay extra for the optional lab test.

Questions

About St Mary Water & Sewer Comm #3

Follow St Mary Water & Sewer Comm #3

Get PurityMap updates about this water system.

Follow this water →
What is the phone number for St Mary Water & Sewer Comm #3?

St Mary Water & Sewer Comm #3's phone number on EPA record is 337-836-5609. Its mailing address is P.O. BOX 119, CENTERVILLE, LA 70522.

Where does St Mary Water & Sewer Comm #3 get its water?

According to EPA's record, St Mary Water & Sewer Comm #3 uses surface water from its own intake.

Does St Mary Water & Sewer Comm #3 have any EPA violations?

EPA's record shows 3 health-based violations for St Mary Water & Sewer Comm #3 in the 10 years to July 9, 2026. No open health-based violations on EPA record in the last 10 years. The latest legal-limit breach on record was in the period starting January 2025. EPA also lists 4 missed or late tests or reports in 10 years. The record comes from EPA's SDWIS compliance database.

What is St Mary Water & Sewer Comm #3's latest lead result?

The 90th-percentile lead result in St Mary Water & Sewer Comm #3's latest lead and copper round, which ended in December 2025, was 3.3 µg/L, below the federal action level of 15 µg/L.

Who do I contact about my St Mary Water & Sewer Comm #3 water bill?

PurityMap has no verified website for St Mary Water & Sewer Comm #3. Its phone number on EPA record is 337-836-5609. Its mailing address on EPA record is P.O. BOX 119, CENTERVILLE, LA 70522. Your water bill lists the ways to contact your supplier and pay. PurityMap does not take payments.