Change
Water utility · Berks County · Pennsylvania

West Reading Boro Water

No open health-based violations on EPA record in the last 10 years.

Serves about 4,300 people (1,523 connections) with surface water bought from Western Berks Water Auth.

  • PWSID PA3060078
  • EPA registered name: WEST READING BORO WATER
  • EPA record checked June 15, 2026
Contact

Contact West Reading Boro Water

From EPA's record for PA3060078. PurityMap is independent of West Reading Boro Water.

Mailing address
500 CHESTNUT ST
WEST READING, PA 19611
Directions ↗

Are you this utility? Correct this listing →

EPA compliance record

What EPA's record shows

1 health-based violation in the last 10 years, from EPA's SDWIS compliance database.

Recent health-based violations for West Reading Boro Water (PWSID PA3060078)
PeriodContaminantMeasuredLegal limitEPA status
From January 2022Surface Water Treatment Rule––Resolved
  • Lead: the 90th-percentile result in the latest lead and copper round (the round ending September 30, 2025) was not detected. The federal action level is 15 µg/L, a trigger for more treatment steps, not a legal limit.
  • Missed or late tests or reports: 4 in 10 years.
  • EPA lists 11 enforcement actions in 10 years; the latest on October 18, 2022.
Lab results EPA required (UCMR 5)

4 of 30 contaminants detected in EPA testing

EPA required this system to test for 30 unregulated and emerging contaminants, from February 2025 to November 2025.

  • Perfluorooctanoic acid (PFOA)Above a historical reference; current applicability unverified
    4 ng/L federal MCL
    4.2ng/L
  • Perfluorohexanoic acid (PFHxA)Within a historical reference; current applicability unverified
    400,000 ng/L Michigan EGLE state MCL · not a federal limit
    3.5ng/L
  • Perfluorobutanesulfonic acid (PFBS)Within the referenced health-based guidance value
    2,000 ng/L EPA health advisory · not a legal limit
    4.7ng/L
  • Perfluoropentanoic acid (PFPeA)Detected, no limit
    No federal limit
    4.1ng/L
Results as a table30 results with limit, status, sample date and source
EPA-required lab results (UCMR 5) for West Reading Boro Water (PWSID PA3060078), Pennsylvania
ContaminantResultLimitStatusSampledSource
Perfluorooctanoic acid (PFOA)4.2 ng/L4.0 ng/L federal MCL (2024)Above a historical reference; current applicability unverified2025-02-05 to 2025-11-05UCMR5 Analytical Results: WEST READING BORO WATER (PA3060078)
Perfluorobutanesulfonic acid (PFBS)4.7 ng/L2,000 ng/L EPA health advisory (screening, not a legal limit)Screening level, not a legal limitWithin the referenced health-based guidance value2025-02-05 to 2025-11-05UCMR5 Analytical Results: WEST READING BORO WATER (PA3060078)
Perfluorohexanoic acid (PFHxA)3.5 ng/L400,000 ng/L Michigan EGLE state MCL (strictest US state)Within a historical reference; current applicability unverified2025-02-05 to 2025-11-05UCMR5 Analytical Results: WEST READING BORO WATER (PA3060078)
Perfluoropentanoic acid (PFPeA)4.1 ng/LNo federal or state limit; shown for transparencyDetected, no limit2025-02-05 to 2025-11-05UCMR5 Analytical Results: WEST READING BORO WATER (PA3060078)
11-Chloroeicosafluoro-3-oxaundecane-1-sulfonic acid (11Cl-PF3OUdS)< 5 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2025-02-05 to 2025-11-05UCMR5 Analytical Results: WEST READING BORO WATER (PA3060078)
1H, 1H, 2H, 2H-perfluorodecane sulfonic acid (8:2 FTS)< 5 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2025-02-05 to 2025-11-05UCMR5 Analytical Results: WEST READING BORO WATER (PA3060078)
1H, 1H, 2H, 2H-perfluorohexane sulfonic acid (4:2 FTS)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2025-02-05 to 2025-11-05UCMR5 Analytical Results: WEST READING BORO WATER (PA3060078)
1H, 1H, 2H, 2H-perfluorooctane sulfonic acid (6:2 FTS)< 5 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2025-02-05 to 2025-11-05UCMR5 Analytical Results: WEST READING BORO WATER (PA3060078)
4,8-Dioxa-3H-perfluorononanoic acid (ADONA)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2025-02-05 to 2025-11-05UCMR5 Analytical Results: WEST READING BORO WATER (PA3060078)
9-Chlorohexadecafluoro-3-oxanone-1-sulfonic acid (9Cl-PF3ONS)< 2 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2025-02-05 to 2025-11-05UCMR5 Analytical Results: WEST READING BORO WATER (PA3060078)
Hexafluoropropylene oxide dimer acid (HFPO-DA) (GenX chemicals)< 5 ng/L10 ng/L federal MCL (2024)Not detected above the reporting limit2025-02-05 to 2025-11-05UCMR5 Analytical Results: WEST READING BORO WATER (PA3060078)
Lithium< 9 µg/L10 µg/L EPA health reference level (screening, not a legal limit)Screening level, not a legal limitNot detected above the reporting limit2025-02-05 to 2025-11-05UCMR5 Analytical Results: WEST READING BORO WATER (PA3060078)
N-ethyl perfluorooctanesulfonamidoacetic acid (NEtFOSAA)< 5 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2025-02-05 to 2025-11-05UCMR5 Analytical Results: WEST READING BORO WATER (PA3060078)
N-methyl perfluorooctanesulfonamidoacetic acid (NMeFOSAA)< 6 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2025-02-05 to 2025-11-05UCMR5 Analytical Results: WEST READING BORO WATER (PA3060078)
Nonafluoro-3,6-dioxaheptanoic acid (NFDHA)< 20 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2025-02-05 to 2025-11-05UCMR5 Analytical Results: WEST READING BORO WATER (PA3060078)
Perfluoro (2-ethoxyethane) sulfonic acid (PFEESA)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2025-02-05 to 2025-11-05UCMR5 Analytical Results: WEST READING BORO WATER (PA3060078)
Perfluoro-3-methoxypropanoic acid (PFMPA)< 4 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2025-02-05 to 2025-11-05UCMR5 Analytical Results: WEST READING BORO WATER (PA3060078)
Perfluoro-4-methoxybutanoic acid (PFMBA)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2025-02-05 to 2025-11-05UCMR5 Analytical Results: WEST READING BORO WATER (PA3060078)
Perfluorobutanoic acid (PFBA)< 5 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2025-02-05 to 2025-11-05UCMR5 Analytical Results: WEST READING BORO WATER (PA3060078)
Perfluorodecanoic acid (PFDA)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2025-02-05 to 2025-11-05UCMR5 Analytical Results: WEST READING BORO WATER (PA3060078)
Perfluorododecanoic acid (PFDoA)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2025-02-05 to 2025-11-05UCMR5 Analytical Results: WEST READING BORO WATER (PA3060078)
Perfluoroheptanesulfonic acid (PFHpS)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2025-02-05 to 2025-11-05UCMR5 Analytical Results: WEST READING BORO WATER (PA3060078)
Perfluoroheptanoic acid (PFHpA)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2025-02-05 to 2025-11-05UCMR5 Analytical Results: WEST READING BORO WATER (PA3060078)
Perfluorohexanesulfonic acid (PFHxS)< 3 ng/L10 ng/L federal MCL (2024)Not detected above the reporting limit2025-02-05 to 2025-11-05UCMR5 Analytical Results: WEST READING BORO WATER (PA3060078)
Perfluorononanoic acid (PFNA)< 4 ng/L10 ng/L federal MCL (2024)Not detected above the reporting limit2025-02-05 to 2025-11-05UCMR5 Analytical Results: WEST READING BORO WATER (PA3060078)
Perfluorooctanesulfonic acid (PFOS)< 4 ng/L4.0 ng/L federal MCL (2024)Not detected above the reporting limit2025-02-05 to 2025-11-05UCMR5 Analytical Results: WEST READING BORO WATER (PA3060078)
Perfluoropentanesulfonic acid (PFPeS)< 4 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2025-02-05 to 2025-11-05UCMR5 Analytical Results: WEST READING BORO WATER (PA3060078)
Perfluorotetradecanoic acid (PFTA)< 8 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2025-02-05 to 2025-11-05UCMR5 Analytical Results: WEST READING BORO WATER (PA3060078)
Perfluorotridecanoic acid (PFTrDA)< 7 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2025-02-05 to 2025-11-05UCMR5 Analytical Results: WEST READING BORO WATER (PA3060078)
Perfluoroundecanoic acid (PFUnA)< 2 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2025-02-05 to 2025-11-05UCMR5 Analytical Results: WEST READING BORO WATER (PA3060078)
Not detected (26)
  • 11-Chloroeicosafluoro-3-oxaundecane-1-sulfonic acid (11Cl-PF3OUdS)
  • 1H, 1H, 2H, 2H-perfluorohexane sulfonic acid (4:2 FTS)
  • 1H, 1H, 2H, 2H-perfluorooctane sulfonic acid (6:2 FTS)
  • 1H, 1H, 2H, 2H-perfluorodecane sulfonic acid (8:2 FTS)
  • 9-Chlorohexadecafluoro-3-oxanone-1-sulfonic acid (9Cl-PF3ONS)
  • 4,8-Dioxa-3H-perfluorononanoic acid (ADONA)
  • Hexafluoropropylene oxide dimer acid (HFPO-DA) (GenX chemicals)
  • N-ethyl perfluorooctanesulfonamidoacetic acid (NEtFOSAA)
  • Nonafluoro-3,6-dioxaheptanoic acid (NFDHA)
  • N-methyl perfluorooctanesulfonamidoacetic acid (NMeFOSAA)
  • Perfluorobutanoic acid (PFBA)
  • Perfluorodecanoic acid (PFDA)
  • Perfluorododecanoic acid (PFDoA)
  • Perfluoro (2-ethoxyethane) sulfonic acid (PFEESA)
  • Perfluoroheptanoic acid (PFHpA)
  • Perfluoroheptanesulfonic acid (PFHpS)
  • Perfluorohexanesulfonic acid (PFHxS)
  • Perfluoro-4-methoxybutanoic acid (PFMBA)
  • Perfluoro-3-methoxypropanoic acid (PFMPA)
  • Perfluorononanoic acid (PFNA)
  • Perfluorooctanesulfonic acid (PFOS)
  • Perfluoropentanesulfonic acid (PFPeS)
  • Perfluorotetradecanoic acid (PFTA)
  • Perfluorotridecanoic acid (PFTrDA)
  • Perfluoroundecanoic acid (PFUnA)
  • Lithium
Commercial · test your own tap

The system record stops at your property line

Screening tells you if something is worth a closer look; a lab result is the number you can act on.

As an Amazon Associate, PurityMap earns from qualifying purchases. Affiliate disclosure

  • Screening: quick check, not lab-grade

    Safe Home DIY Lead in Drinking Water Combo Test Kit

    Safe Home (EnviroTestKits)

    Lead, read as one of three ranges: 0–4, 5–15 or 15+ ppb

    Turnaround: 5 minutes

    What it can't tell you: It shows a lead range, not an exact level, and tests nothing else unless you pay extra for the optional lab test.

Questions

About West Reading Boro Water

Follow West Reading Boro Water

Get PurityMap updates about this water system.

Follow this water →
What is the phone number for West Reading Boro Water?

West Reading Boro Water's phone number on EPA record is 610-374-8273. Its mailing address is 500 CHESTNUT ST, WEST READING, PA 19611.

Where does West Reading Boro Water get its water?

According to EPA's record, West Reading Boro Water uses surface water bought from Western Berks Water Auth.

Does West Reading Boro Water have any EPA violations?

EPA's record shows 1 health-based violation for West Reading Boro Water in the 10 years to July 9, 2026. No open health-based violations on EPA record in the last 10 years. EPA also lists 4 missed or late tests or reports in 10 years. The record comes from EPA's SDWIS compliance database.

What is West Reading Boro Water's latest lead result?

Lead was not detected at the 90th percentile of tap samples in West Reading Boro Water's latest lead and copper round, which ended in September 2025. The federal action level is 15 µg/L.

Who do I contact about my West Reading Boro Water water bill?

PurityMap has no verified website for West Reading Boro Water. Its phone number on EPA record is 610-374-8273. Its mailing address on EPA record is 500 CHESTNUT ST, WEST READING, PA 19611. Your water bill lists the ways to contact your supplier and pay. PurityMap does not take payments.