Change
Water utility · Sioux Falls · South Dakota

Lincoln County Rural Water System

No health-based violations on EPA record since 2016.

Serves about 5,965 people (2,386 connections) with groundwater bought from Lewis and Clark Regional Water Syste.

  • PWSID SD4600304
  • EPA registered name: LINCOLN COUNTY RURAL WATER SYSTEM
  • EPA record checked June 17, 2026
Contact

Contact Lincoln County Rural Water System

From EPA's record for SD4600304. PurityMap is independent of Lincoln County Rural Water System.

Mailing address
27066 HENRY PLACE
SIOUX FALLS, SD 57108
Directions ↗

Are you this utility? Correct this listing →

EPA compliance record

What EPA's record shows

No health-based violations in the last 10 years, from EPA's SDWIS compliance database.

  • Lead: the 90th-percentile result in the latest lead and copper round (the round ending December 31, 2024) was 2 µg/L. The federal action level is 15 µg/L, a trigger for more treatment steps, not a legal limit.
  • Missed or late tests or reports: 1 in 10 years.
  • EPA lists 3 enforcement actions in 10 years; the latest on June 16, 2025.
Lab results EPA required (UCMR 5)

2 of 30 contaminants detected in EPA testing

EPA required this system to test for 30 unregulated and emerging contaminants, from March 2023 to April 2024.

  • LithiumAbove the referenced health-based guidance value
    10 µg/L EPA health reference level · not a legal limit
    55µg/L
  • Perfluorobutanoic acid (PFBA)Detected, no limit
    No federal limit
    6.1ng/L
Results as a table30 results with limit, status, sample date and source
EPA-required lab results (UCMR 5) for Lincoln County Rural Water System (PWSID SD4600304), South Dakota
ContaminantResultLimitStatusSampledSource
Lithium55 µg/L10 µg/L EPA health reference level (screening, not a legal limit)Screening level, not a legal limitAbove the referenced health-based guidance value2023-03-06 to 2023-09-06UCMR5 Analytical Results: LINCOLN COUNTY RURAL WATER SYSTEM (SD4600304)
Perfluorobutanoic acid (PFBA)6.1 ng/LNo federal or state limit; shown for transparencyDetected, no limit2023-03-27 to 2024-04-09UCMR5 Analytical Results: LINCOLN COUNTY RURAL WATER SYSTEM (SD4600304)
11-Chloroeicosafluoro-3-oxaundecane-1-sulfonic acid (11Cl-PF3OUdS)< 5 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2023-03-27 to 2024-04-09UCMR5 Analytical Results: LINCOLN COUNTY RURAL WATER SYSTEM (SD4600304)
1H, 1H, 2H, 2H-perfluorodecane sulfonic acid (8:2 FTS)< 5 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2023-03-27 to 2024-04-09UCMR5 Analytical Results: LINCOLN COUNTY RURAL WATER SYSTEM (SD4600304)
1H, 1H, 2H, 2H-perfluorohexane sulfonic acid (4:2 FTS)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2023-03-27 to 2024-04-09UCMR5 Analytical Results: LINCOLN COUNTY RURAL WATER SYSTEM (SD4600304)
1H, 1H, 2H, 2H-perfluorooctane sulfonic acid (6:2 FTS)< 5 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2023-03-27 to 2024-04-09UCMR5 Analytical Results: LINCOLN COUNTY RURAL WATER SYSTEM (SD4600304)
4,8-Dioxa-3H-perfluorononanoic acid (ADONA)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2023-03-27 to 2024-04-09UCMR5 Analytical Results: LINCOLN COUNTY RURAL WATER SYSTEM (SD4600304)
9-Chlorohexadecafluoro-3-oxanone-1-sulfonic acid (9Cl-PF3ONS)< 2 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2023-03-27 to 2024-04-09UCMR5 Analytical Results: LINCOLN COUNTY RURAL WATER SYSTEM (SD4600304)
Hexafluoropropylene oxide dimer acid (HFPO-DA) (GenX chemicals)< 5 ng/L10 ng/L federal MCL (2024)Not detected above the reporting limit2023-03-27 to 2024-04-09UCMR5 Analytical Results: LINCOLN COUNTY RURAL WATER SYSTEM (SD4600304)
N-ethyl perfluorooctanesulfonamidoacetic acid (NEtFOSAA)< 5 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2023-03-06 to 2023-10-23UCMR5 Analytical Results: LINCOLN COUNTY RURAL WATER SYSTEM (SD4600304)
N-methyl perfluorooctanesulfonamidoacetic acid (NMeFOSAA)< 6 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2023-03-06 to 2023-10-23UCMR5 Analytical Results: LINCOLN COUNTY RURAL WATER SYSTEM (SD4600304)
Nonafluoro-3,6-dioxaheptanoic acid (NFDHA)< 20 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2023-03-27 to 2024-04-09UCMR5 Analytical Results: LINCOLN COUNTY RURAL WATER SYSTEM (SD4600304)
Perfluoro (2-ethoxyethane) sulfonic acid (PFEESA)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2023-03-27 to 2024-04-09UCMR5 Analytical Results: LINCOLN COUNTY RURAL WATER SYSTEM (SD4600304)
Perfluoro-3-methoxypropanoic acid (PFMPA)< 4 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2023-03-27 to 2024-04-09UCMR5 Analytical Results: LINCOLN COUNTY RURAL WATER SYSTEM (SD4600304)
Perfluoro-4-methoxybutanoic acid (PFMBA)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2023-03-27 to 2024-04-09UCMR5 Analytical Results: LINCOLN COUNTY RURAL WATER SYSTEM (SD4600304)
Perfluorobutanesulfonic acid (PFBS)< 3 ng/L2,000 ng/L EPA health advisory (screening, not a legal limit)Screening level, not a legal limitNot detected above the reporting limit2023-03-27 to 2024-04-09UCMR5 Analytical Results: LINCOLN COUNTY RURAL WATER SYSTEM (SD4600304)
Perfluorodecanoic acid (PFDA)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2023-03-27 to 2024-04-09UCMR5 Analytical Results: LINCOLN COUNTY RURAL WATER SYSTEM (SD4600304)
Perfluorododecanoic acid (PFDoA)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2023-03-27 to 2024-04-09UCMR5 Analytical Results: LINCOLN COUNTY RURAL WATER SYSTEM (SD4600304)
Perfluoroheptanesulfonic acid (PFHpS)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2023-03-27 to 2024-04-09UCMR5 Analytical Results: LINCOLN COUNTY RURAL WATER SYSTEM (SD4600304)
Perfluoroheptanoic acid (PFHpA)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2023-03-27 to 2024-04-09UCMR5 Analytical Results: LINCOLN COUNTY RURAL WATER SYSTEM (SD4600304)
Perfluorohexanesulfonic acid (PFHxS)< 3 ng/L10 ng/L federal MCL (2024)Not detected above the reporting limit2023-03-27 to 2024-04-09UCMR5 Analytical Results: LINCOLN COUNTY RURAL WATER SYSTEM (SD4600304)
Perfluorohexanoic acid (PFHxA)< 3 ng/L400,000 ng/L Michigan EGLE state MCL (strictest US state)Not detected above the reporting limit2023-03-27 to 2024-04-09UCMR5 Analytical Results: LINCOLN COUNTY RURAL WATER SYSTEM (SD4600304)
Perfluorononanoic acid (PFNA)< 4 ng/L10 ng/L federal MCL (2024)Not detected above the reporting limit2023-03-27 to 2024-04-09UCMR5 Analytical Results: LINCOLN COUNTY RURAL WATER SYSTEM (SD4600304)
Perfluorooctanesulfonic acid (PFOS)< 4 ng/L4.0 ng/L federal MCL (2024)Not detected above the reporting limit2023-03-27 to 2024-04-09UCMR5 Analytical Results: LINCOLN COUNTY RURAL WATER SYSTEM (SD4600304)
Perfluorooctanoic acid (PFOA)< 4 ng/L4.0 ng/L federal MCL (2024)Not detected above the reporting limit2023-03-27 to 2024-04-09UCMR5 Analytical Results: LINCOLN COUNTY RURAL WATER SYSTEM (SD4600304)
Perfluoropentanesulfonic acid (PFPeS)< 4 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2023-03-27 to 2024-04-09UCMR5 Analytical Results: LINCOLN COUNTY RURAL WATER SYSTEM (SD4600304)
Perfluoropentanoic acid (PFPeA)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2023-03-27 to 2024-04-09UCMR5 Analytical Results: LINCOLN COUNTY RURAL WATER SYSTEM (SD4600304)
Perfluorotetradecanoic acid (PFTA)< 8 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2023-03-06 to 2023-10-23UCMR5 Analytical Results: LINCOLN COUNTY RURAL WATER SYSTEM (SD4600304)
Perfluorotridecanoic acid (PFTrDA)< 7 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2023-03-06 to 2023-10-23UCMR5 Analytical Results: LINCOLN COUNTY RURAL WATER SYSTEM (SD4600304)
Perfluoroundecanoic acid (PFUnA)< 2 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2023-03-27 to 2024-04-09UCMR5 Analytical Results: LINCOLN COUNTY RURAL WATER SYSTEM (SD4600304)
Not detected (28)
  • 11-Chloroeicosafluoro-3-oxaundecane-1-sulfonic acid (11Cl-PF3OUdS)
  • 1H, 1H, 2H, 2H-perfluorohexane sulfonic acid (4:2 FTS)
  • 1H, 1H, 2H, 2H-perfluorooctane sulfonic acid (6:2 FTS)
  • 1H, 1H, 2H, 2H-perfluorodecane sulfonic acid (8:2 FTS)
  • 9-Chlorohexadecafluoro-3-oxanone-1-sulfonic acid (9Cl-PF3ONS)
  • 4,8-Dioxa-3H-perfluorononanoic acid (ADONA)
  • Hexafluoropropylene oxide dimer acid (HFPO-DA) (GenX chemicals)
  • N-ethyl perfluorooctanesulfonamidoacetic acid (NEtFOSAA)
  • Nonafluoro-3,6-dioxaheptanoic acid (NFDHA)
  • N-methyl perfluorooctanesulfonamidoacetic acid (NMeFOSAA)
  • Perfluorobutanesulfonic acid (PFBS)
  • Perfluorodecanoic acid (PFDA)
  • Perfluorododecanoic acid (PFDoA)
  • Perfluoro (2-ethoxyethane) sulfonic acid (PFEESA)
  • Perfluoroheptanoic acid (PFHpA)
  • Perfluoroheptanesulfonic acid (PFHpS)
  • Perfluorohexanoic acid (PFHxA)
  • Perfluorohexanesulfonic acid (PFHxS)
  • Perfluoro-4-methoxybutanoic acid (PFMBA)
  • Perfluoro-3-methoxypropanoic acid (PFMPA)
  • Perfluorononanoic acid (PFNA)
  • Perfluorooctanoic acid (PFOA)
  • Perfluorooctanesulfonic acid (PFOS)
  • Perfluoropentanoic acid (PFPeA)
  • Perfluoropentanesulfonic acid (PFPeS)
  • Perfluorotetradecanoic acid (PFTA)
  • Perfluorotridecanoic acid (PFTrDA)
  • Perfluoroundecanoic acid (PFUnA)
Commercial · test your own tap

The system record stops at your property line

Screening tells you if something is worth a closer look; a lab result is the number you can act on.

As an Amazon Associate, PurityMap earns from qualifying purchases. Affiliate disclosure

  • Screening: quick check, not lab-grade

    Safe Home DIY Lead in Drinking Water Combo Test Kit

    Safe Home (EnviroTestKits)

    Lead, read as one of three ranges: 0–4, 5–15 or 15+ ppb

    Turnaround: 5 minutes

    What it can't tell you: It shows a lead range, not an exact level, and tests nothing else unless you pay extra for the optional lab test.

Questions

About Lincoln County Rural Water System

Follow Lincoln County Rural Water System

Get PurityMap updates about this water system.

Follow this water →
What is the phone number for Lincoln County Rural Water System?

Lincoln County Rural Water System's phone number on EPA record is 6057672966. Its mailing address is 27066 HENRY PLACE, SIOUX FALLS, SD 57108.

Where does Lincoln County Rural Water System get its water?

According to EPA's record, Lincoln County Rural Water System uses groundwater bought from Lewis and Clark Regional Water Syste.

Does Lincoln County Rural Water System have any EPA violations?

No health-based violations on EPA record since 2016. EPA also lists 1 missed or late test or report in 10 years. The record comes from EPA's SDWIS compliance database.

What is Lincoln County Rural Water System's latest lead result?

The 90th-percentile lead result in Lincoln County Rural Water System's latest lead and copper round, which ended in December 2024, was 2 µg/L, below the federal action level of 15 µg/L.

Who do I contact about my Lincoln County Rural Water System water bill?

PurityMap has no verified website for Lincoln County Rural Water System. Its phone number on EPA record is 6057672966. Its mailing address on EPA record is 27066 HENRY PLACE, SIOUX FALLS, SD 57108. Your water bill lists the ways to contact your supplier and pay. PurityMap does not take payments.