Change
Water utility · Dunlap · Tennessee

Dunlap Water System

No health-based violations on EPA record since 2016.

Serves about 9,782 people (3,691 connections) with surface water from its own intake.

  • PWSID TN0000205
  • EPA registered name: DUNLAP WATER SYSTEM
  • EPA record checked May 14, 2026
Contact

Contact Dunlap Water System

From EPA's record for TN0000205. PurityMap is independent of Dunlap Water System.

Mailing address
15595 RANKIN AVE, P.O. BOX 546
DUNLAP, TN 37327
Directions ↗

Are you this utility? Correct this listing →

EPA compliance record

What EPA's record shows

No health-based violations in the last 10 years, from EPA's SDWIS compliance database.

  • Lead: the 90th-percentile result in the latest lead and copper round (the round ending December 31, 2025) was 1 µg/L. The federal action level is 15 µg/L, a trigger for more treatment steps, not a legal limit.
  • Missed or late tests or reports: 11 in 10 years.
  • EPA lists 19 enforcement actions in 10 years; the latest on November 21, 2025.
Lab results EPA required (UCMR 5)

None of the contaminants were detected in EPA testing

EPA required this system to test for 30 unregulated and emerging contaminants, from April 2024 to December 2024.

Results as a table30 results with limit, status, sample date and source
EPA-required lab results (UCMR 5) for Dunlap Water System (PWSID TN0000205), Tennessee
ContaminantResultLimitStatusSampledSource
11-Chloroeicosafluoro-3-oxaundecane-1-sulfonic acid (11Cl-PF3OUdS)< 5 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-04-01 to 2024-12-16UCMR5 Analytical Results: DUNLAP WATER SYSTEM (TN0000205)
1H, 1H, 2H, 2H-perfluorodecane sulfonic acid (8:2 FTS)< 5 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-04-01 to 2024-12-16UCMR5 Analytical Results: DUNLAP WATER SYSTEM (TN0000205)
1H, 1H, 2H, 2H-perfluorohexane sulfonic acid (4:2 FTS)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-04-01 to 2024-12-16UCMR5 Analytical Results: DUNLAP WATER SYSTEM (TN0000205)
1H, 1H, 2H, 2H-perfluorooctane sulfonic acid (6:2 FTS)< 5 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-04-01 to 2024-12-16UCMR5 Analytical Results: DUNLAP WATER SYSTEM (TN0000205)
4,8-Dioxa-3H-perfluorononanoic acid (ADONA)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-04-01 to 2024-12-16UCMR5 Analytical Results: DUNLAP WATER SYSTEM (TN0000205)
9-Chlorohexadecafluoro-3-oxanone-1-sulfonic acid (9Cl-PF3ONS)< 2 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-04-01 to 2024-12-16UCMR5 Analytical Results: DUNLAP WATER SYSTEM (TN0000205)
Hexafluoropropylene oxide dimer acid (HFPO-DA) (GenX chemicals)< 5 ng/L10 ng/L federal MCL (2024)Not detected above the reporting limit2024-04-01 to 2024-12-16UCMR5 Analytical Results: DUNLAP WATER SYSTEM (TN0000205)
Lithium< 9 µg/L10 µg/L EPA health reference level (screening, not a legal limit)Screening level, not a legal limitNot detected above the reporting limit2024-04-01 to 2024-11-13UCMR5 Analytical Results: DUNLAP WATER SYSTEM (TN0000205)
N-ethyl perfluorooctanesulfonamidoacetic acid (NEtFOSAA)< 5 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-04-01 to 2024-12-16UCMR5 Analytical Results: DUNLAP WATER SYSTEM (TN0000205)
N-methyl perfluorooctanesulfonamidoacetic acid (NMeFOSAA)< 6 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-04-01 to 2024-12-16UCMR5 Analytical Results: DUNLAP WATER SYSTEM (TN0000205)
Nonafluoro-3,6-dioxaheptanoic acid (NFDHA)< 20 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-04-01 to 2024-12-16UCMR5 Analytical Results: DUNLAP WATER SYSTEM (TN0000205)
Perfluoro (2-ethoxyethane) sulfonic acid (PFEESA)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-04-01 to 2024-12-16UCMR5 Analytical Results: DUNLAP WATER SYSTEM (TN0000205)
Perfluoro-3-methoxypropanoic acid (PFMPA)< 4 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-04-01 to 2024-12-16UCMR5 Analytical Results: DUNLAP WATER SYSTEM (TN0000205)
Perfluoro-4-methoxybutanoic acid (PFMBA)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-04-01 to 2024-12-16UCMR5 Analytical Results: DUNLAP WATER SYSTEM (TN0000205)
Perfluorobutanesulfonic acid (PFBS)< 3 ng/L2,000 ng/L EPA health advisory (screening, not a legal limit)Screening level, not a legal limitNot detected above the reporting limit2024-04-01 to 2024-12-16UCMR5 Analytical Results: DUNLAP WATER SYSTEM (TN0000205)
Perfluorobutanoic acid (PFBA)< 5 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-04-01 to 2024-12-16UCMR5 Analytical Results: DUNLAP WATER SYSTEM (TN0000205)
Perfluorodecanoic acid (PFDA)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-04-01 to 2024-12-16UCMR5 Analytical Results: DUNLAP WATER SYSTEM (TN0000205)
Perfluorododecanoic acid (PFDoA)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-04-01 to 2024-12-16UCMR5 Analytical Results: DUNLAP WATER SYSTEM (TN0000205)
Perfluoroheptanesulfonic acid (PFHpS)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-04-01 to 2024-12-16UCMR5 Analytical Results: DUNLAP WATER SYSTEM (TN0000205)
Perfluoroheptanoic acid (PFHpA)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-04-01 to 2024-12-16UCMR5 Analytical Results: DUNLAP WATER SYSTEM (TN0000205)
Perfluorohexanesulfonic acid (PFHxS)< 3 ng/L10 ng/L federal MCL (2024)Not detected above the reporting limit2024-04-01 to 2024-12-16UCMR5 Analytical Results: DUNLAP WATER SYSTEM (TN0000205)
Perfluorohexanoic acid (PFHxA)< 3 ng/L400,000 ng/L Michigan EGLE state MCL (strictest US state)Not detected above the reporting limit2024-04-01 to 2024-12-16UCMR5 Analytical Results: DUNLAP WATER SYSTEM (TN0000205)
Perfluorononanoic acid (PFNA)< 4 ng/L10 ng/L federal MCL (2024)Not detected above the reporting limit2024-04-01 to 2024-12-16UCMR5 Analytical Results: DUNLAP WATER SYSTEM (TN0000205)
Perfluorooctanesulfonic acid (PFOS)< 4 ng/L4.0 ng/L federal MCL (2024)Not detected above the reporting limit2024-04-01 to 2024-12-16UCMR5 Analytical Results: DUNLAP WATER SYSTEM (TN0000205)
Perfluorooctanoic acid (PFOA)< 4 ng/L4.0 ng/L federal MCL (2024)Not detected above the reporting limit2024-04-01 to 2024-12-16UCMR5 Analytical Results: DUNLAP WATER SYSTEM (TN0000205)
Perfluoropentanesulfonic acid (PFPeS)< 4 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-04-01 to 2024-12-16UCMR5 Analytical Results: DUNLAP WATER SYSTEM (TN0000205)
Perfluoropentanoic acid (PFPeA)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-04-01 to 2024-12-16UCMR5 Analytical Results: DUNLAP WATER SYSTEM (TN0000205)
Perfluorotetradecanoic acid (PFTA)< 8 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-04-01 to 2024-12-16UCMR5 Analytical Results: DUNLAP WATER SYSTEM (TN0000205)
Perfluorotridecanoic acid (PFTrDA)< 7 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-04-01 to 2024-12-16UCMR5 Analytical Results: DUNLAP WATER SYSTEM (TN0000205)
Perfluoroundecanoic acid (PFUnA)< 2 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-04-01 to 2024-12-16UCMR5 Analytical Results: DUNLAP WATER SYSTEM (TN0000205)
Not detected (30)
  • 11-Chloroeicosafluoro-3-oxaundecane-1-sulfonic acid (11Cl-PF3OUdS)
  • 1H, 1H, 2H, 2H-perfluorohexane sulfonic acid (4:2 FTS)
  • 1H, 1H, 2H, 2H-perfluorooctane sulfonic acid (6:2 FTS)
  • 1H, 1H, 2H, 2H-perfluorodecane sulfonic acid (8:2 FTS)
  • 9-Chlorohexadecafluoro-3-oxanone-1-sulfonic acid (9Cl-PF3ONS)
  • 4,8-Dioxa-3H-perfluorononanoic acid (ADONA)
  • Hexafluoropropylene oxide dimer acid (HFPO-DA) (GenX chemicals)
  • N-ethyl perfluorooctanesulfonamidoacetic acid (NEtFOSAA)
  • Nonafluoro-3,6-dioxaheptanoic acid (NFDHA)
  • N-methyl perfluorooctanesulfonamidoacetic acid (NMeFOSAA)
  • Perfluorobutanoic acid (PFBA)
  • Perfluorobutanesulfonic acid (PFBS)
  • Perfluorodecanoic acid (PFDA)
  • Perfluorododecanoic acid (PFDoA)
  • Perfluoro (2-ethoxyethane) sulfonic acid (PFEESA)
  • Perfluoroheptanoic acid (PFHpA)
  • Perfluoroheptanesulfonic acid (PFHpS)
  • Perfluorohexanoic acid (PFHxA)
  • Perfluorohexanesulfonic acid (PFHxS)
  • Perfluoro-4-methoxybutanoic acid (PFMBA)
  • Perfluoro-3-methoxypropanoic acid (PFMPA)
  • Perfluorononanoic acid (PFNA)
  • Perfluorooctanoic acid (PFOA)
  • Perfluorooctanesulfonic acid (PFOS)
  • Perfluoropentanoic acid (PFPeA)
  • Perfluoropentanesulfonic acid (PFPeS)
  • Perfluorotetradecanoic acid (PFTA)
  • Perfluorotridecanoic acid (PFTrDA)
  • Perfluoroundecanoic acid (PFUnA)
  • Lithium
Commercial · test your own tap

The system record stops at your property line

Screening tells you if something is worth a closer look; a lab result is the number you can act on.

As an Amazon Associate, PurityMap earns from qualifying purchases. Affiliate disclosure

  • Screening: quick check, not lab-grade

    Safe Home DIY Lead in Drinking Water Combo Test Kit

    Safe Home (EnviroTestKits)

    Lead, read as one of three ranges: 0–4, 5–15 or 15+ ppb

    Turnaround: 5 minutes

    What it can't tell you: It shows a lead range, not an exact level, and tests nothing else unless you pay extra for the optional lab test.

Questions

About Dunlap Water System

Follow Dunlap Water System

Get PurityMap updates about this water system.

Follow this water →
What is the phone number for Dunlap Water System?

Dunlap Water System's phone number on EPA record is 423-718-3435. Its mailing address is 15595 RANKIN AVE, P.O. BOX 546, DUNLAP, TN 37327.

Where does Dunlap Water System get its water?

According to EPA's record, Dunlap Water System uses surface water from its own intake.

Does Dunlap Water System have any EPA violations?

No health-based violations on EPA record since 2016. EPA also lists 11 missed or late tests or reports in 10 years. The record comes from EPA's SDWIS compliance database.

What is Dunlap Water System's latest lead result?

The 90th-percentile lead result in Dunlap Water System's latest lead and copper round, which ended in December 2025, was 1 µg/L, below the federal action level of 15 µg/L.

Who do I contact about my Dunlap Water System water bill?

PurityMap has no verified website for Dunlap Water System. Its phone number on EPA record is 423-718-3435. Its mailing address on EPA record is 15595 RANKIN AVE, P.O. BOX 546, DUNLAP, TN 37327. Your water bill lists the ways to contact your supplier and pay. PurityMap does not take payments.