Water utility · Angelina County · Texas

Four Way SUD

No health-based violations on EPA record since 2016.

Serves about 6,684 people (2,571 connections) with groundwater from its own wells, and buys water from City of Lufkin and City of Huntington.

  • PWSID TX0030020
  • EPA registered name: FOUR WAY SUD
  • EPA record checked June 26, 2026
Contact

Contact Four Way SUD

From EPA's record for TX0030020. PurityMap is independent of Four Way SUD.

Mailing address
411 N MAIN ST
HUNTINGTON, TX 75949-8420
Directions ↗

Are you this utility? Correct this listing →

EPA compliance record

What EPA's record shows

No health-based violations in the last 10 years, from EPA's SDWIS compliance database.

  • Lead: the 90th-percentile result in the latest lead and copper round (the round ending December 31, 2025) was 1.36 µg/L. The federal action level is 15 µg/L, a trigger for more treatment steps, not a legal limit.
  • Missed or late tests or reports: none in 10 years.
  • EPA lists no enforcement actions in 10 years.
Lab results EPA required (UCMR 5)

2 of 30 contaminants detected in EPA testing

EPA required this system to test for 30 unregulated and emerging contaminants, from January 2024 to July 2024.

  • LithiumAbove the referenced health-based guidance value
    10 µg/L EPA health reference level · not a legal limit
    16.7µg/L
  • 1H, 1H, 2H, 2H-perfluorooctane sulfonic acid (6:2 FTS)Detected, no limit
    No federal limit
    54.6ng/L
Results as a table30 results with limit, status, sample date and source
EPA-required lab results (UCMR 5) for Four Way SUD (PWSID TX0030020), Texas
ContaminantResultLimitStatusSampledSource
Lithium16.7 µg/L10 µg/L EPA health reference level (screening, not a legal limit)Screening level, not a legal limitAbove the referenced health-based guidance value2024-01-08 to 2024-07-10UCMR5 Analytical Results: FOUR WAY SUD (TX0030020)
1H, 1H, 2H, 2H-perfluorooctane sulfonic acid (6:2 FTS)54.6 ng/LNo federal or state limit; shown for transparencyDetected, no limit2024-01-08 to 2024-07-10UCMR5 Analytical Results: FOUR WAY SUD (TX0030020)
11-Chloroeicosafluoro-3-oxaundecane-1-sulfonic acid (11Cl-PF3OUdS)< 5 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-01-08 to 2024-07-10UCMR5 Analytical Results: FOUR WAY SUD (TX0030020)
1H, 1H, 2H, 2H-perfluorodecane sulfonic acid (8:2 FTS)< 5 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-01-08 to 2024-07-10UCMR5 Analytical Results: FOUR WAY SUD (TX0030020)
1H, 1H, 2H, 2H-perfluorohexane sulfonic acid (4:2 FTS)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-01-08 to 2024-07-10UCMR5 Analytical Results: FOUR WAY SUD (TX0030020)
4,8-Dioxa-3H-perfluorononanoic acid (ADONA)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-01-08 to 2024-07-10UCMR5 Analytical Results: FOUR WAY SUD (TX0030020)
9-Chlorohexadecafluoro-3-oxanone-1-sulfonic acid (9Cl-PF3ONS)< 2 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-01-08 to 2024-07-10UCMR5 Analytical Results: FOUR WAY SUD (TX0030020)
Hexafluoropropylene oxide dimer acid (HFPO-DA) (GenX chemicals)< 5 ng/L10 ng/L federal MCL (2024)Not detected above the reporting limit2024-01-08 to 2024-07-10UCMR5 Analytical Results: FOUR WAY SUD (TX0030020)
N-ethyl perfluorooctanesulfonamidoacetic acid (NEtFOSAA)< 5 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-01-08 to 2024-07-10UCMR5 Analytical Results: FOUR WAY SUD (TX0030020)
N-methyl perfluorooctanesulfonamidoacetic acid (NMeFOSAA)< 6 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-01-08 to 2024-07-10UCMR5 Analytical Results: FOUR WAY SUD (TX0030020)
Nonafluoro-3,6-dioxaheptanoic acid (NFDHA)< 20 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-01-08 to 2024-07-10UCMR5 Analytical Results: FOUR WAY SUD (TX0030020)
Perfluoro (2-ethoxyethane) sulfonic acid (PFEESA)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-01-08 to 2024-07-10UCMR5 Analytical Results: FOUR WAY SUD (TX0030020)
Perfluoro-3-methoxypropanoic acid (PFMPA)< 4 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-01-08 to 2024-07-10UCMR5 Analytical Results: FOUR WAY SUD (TX0030020)
Perfluoro-4-methoxybutanoic acid (PFMBA)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-01-08 to 2024-07-10UCMR5 Analytical Results: FOUR WAY SUD (TX0030020)
Perfluorobutanesulfonic acid (PFBS)< 3 ng/L2,000 ng/L EPA health advisory (screening, not a legal limit)Screening level, not a legal limitNot detected above the reporting limit2024-01-08 to 2024-07-10UCMR5 Analytical Results: FOUR WAY SUD (TX0030020)
Perfluorobutanoic acid (PFBA)< 5 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-01-08 to 2024-07-10UCMR5 Analytical Results: FOUR WAY SUD (TX0030020)
Perfluorodecanoic acid (PFDA)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-01-08 to 2024-07-10UCMR5 Analytical Results: FOUR WAY SUD (TX0030020)
Perfluorododecanoic acid (PFDoA)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-01-08 to 2024-07-10UCMR5 Analytical Results: FOUR WAY SUD (TX0030020)
Perfluoroheptanesulfonic acid (PFHpS)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-01-08 to 2024-07-10UCMR5 Analytical Results: FOUR WAY SUD (TX0030020)
Perfluoroheptanoic acid (PFHpA)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-01-08 to 2024-07-10UCMR5 Analytical Results: FOUR WAY SUD (TX0030020)
Perfluorohexanesulfonic acid (PFHxS)< 3 ng/L10 ng/L federal MCL (2024)Not detected above the reporting limit2024-01-08 to 2024-07-10UCMR5 Analytical Results: FOUR WAY SUD (TX0030020)
Perfluorohexanoic acid (PFHxA)< 3 ng/L400,000 ng/L Michigan EGLE state MCL (strictest US state)Not detected above the reporting limit2024-01-08 to 2024-07-10UCMR5 Analytical Results: FOUR WAY SUD (TX0030020)
Perfluorononanoic acid (PFNA)< 4 ng/L10 ng/L federal MCL (2024)Not detected above the reporting limit2024-01-08 to 2024-07-10UCMR5 Analytical Results: FOUR WAY SUD (TX0030020)
Perfluorooctanesulfonic acid (PFOS)< 4 ng/L4.0 ng/L federal MCL (2024)Not detected above the reporting limit2024-01-08 to 2024-07-10UCMR5 Analytical Results: FOUR WAY SUD (TX0030020)
Perfluorooctanoic acid (PFOA)< 4 ng/L4.0 ng/L federal MCL (2024)Not detected above the reporting limit2024-01-08 to 2024-07-10UCMR5 Analytical Results: FOUR WAY SUD (TX0030020)
Perfluoropentanesulfonic acid (PFPeS)< 4 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-01-08 to 2024-07-10UCMR5 Analytical Results: FOUR WAY SUD (TX0030020)
Perfluoropentanoic acid (PFPeA)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-01-08 to 2024-07-10UCMR5 Analytical Results: FOUR WAY SUD (TX0030020)
Perfluorotetradecanoic acid (PFTA)< 8 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-01-08 to 2024-07-10UCMR5 Analytical Results: FOUR WAY SUD (TX0030020)
Perfluorotridecanoic acid (PFTrDA)< 7 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-01-08 to 2024-07-10UCMR5 Analytical Results: FOUR WAY SUD (TX0030020)
Perfluoroundecanoic acid (PFUnA)< 2 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2024-01-08 to 2024-07-10UCMR5 Analytical Results: FOUR WAY SUD (TX0030020)
Not detected (28)
  • 11-Chloroeicosafluoro-3-oxaundecane-1-sulfonic acid (11Cl-PF3OUdS)
  • 1H, 1H, 2H, 2H-perfluorohexane sulfonic acid (4:2 FTS)
  • 1H, 1H, 2H, 2H-perfluorodecane sulfonic acid (8:2 FTS)
  • 9-Chlorohexadecafluoro-3-oxanone-1-sulfonic acid (9Cl-PF3ONS)
  • 4,8-Dioxa-3H-perfluorononanoic acid (ADONA)
  • Hexafluoropropylene oxide dimer acid (HFPO-DA) (GenX chemicals)
  • N-ethyl perfluorooctanesulfonamidoacetic acid (NEtFOSAA)
  • Nonafluoro-3,6-dioxaheptanoic acid (NFDHA)
  • N-methyl perfluorooctanesulfonamidoacetic acid (NMeFOSAA)
  • Perfluorobutanoic acid (PFBA)
  • Perfluorobutanesulfonic acid (PFBS)
  • Perfluorodecanoic acid (PFDA)
  • Perfluorododecanoic acid (PFDoA)
  • Perfluoro (2-ethoxyethane) sulfonic acid (PFEESA)
  • Perfluoroheptanoic acid (PFHpA)
  • Perfluoroheptanesulfonic acid (PFHpS)
  • Perfluorohexanoic acid (PFHxA)
  • Perfluorohexanesulfonic acid (PFHxS)
  • Perfluoro-4-methoxybutanoic acid (PFMBA)
  • Perfluoro-3-methoxypropanoic acid (PFMPA)
  • Perfluorononanoic acid (PFNA)
  • Perfluorooctanoic acid (PFOA)
  • Perfluorooctanesulfonic acid (PFOS)
  • Perfluoropentanoic acid (PFPeA)
  • Perfluoropentanesulfonic acid (PFPeS)
  • Perfluorotetradecanoic acid (PFTA)
  • Perfluorotridecanoic acid (PFTrDA)
  • Perfluoroundecanoic acid (PFUnA)
Commercial · test your own tap

The system record stops at your property line

Screening tells you if something is worth a closer look; a lab result is the number you can act on.

As an Amazon Associate, PurityMap earns from qualifying purchases. Affiliate disclosure

  • Screening: quick check, not lab-grade

    Safe Home DIY Lead in Drinking Water Combo Test Kit

    Safe Home (EnviroTestKits)

    Lead, read as one of three ranges: 0–4, 5–15 or 15+ ppb

    Turnaround: 5 minutes

    What it can't tell you: It shows a lead range, not an exact level, and tests nothing else unless you pay extra for the optional lab test.

Questions

About Four Way SUD

Follow Four Way SUD

Get PurityMap updates about this water system.

Follow this water →
What is the phone number for Four Way SUD?

Four Way SUD's phone number on EPA record is 936-422-4188. Its mailing address is 411 N MAIN ST, HUNTINGTON, TX 75949-8420.

Where does Four Way SUD get its water?

According to EPA's record, Four Way SUD uses groundwater from its own wells, and buys water from City of Lufkin and City of Huntington.

Does Four Way SUD have any EPA violations?

No health-based violations on EPA record since 2016. The record comes from EPA's SDWIS compliance database.

What is Four Way SUD's latest lead result?

The 90th-percentile lead result in Four Way SUD's latest lead and copper round, which ended in December 2025, was 1.36 µg/L, below the federal action level of 15 µg/L.

Who do I contact about my Four Way SUD water bill?

PurityMap has no verified website for Four Way SUD. Its phone number on EPA record is 936-422-4188. Its mailing address on EPA record is 411 N MAIN ST, HUNTINGTON, TX 75949-8420. Your water bill lists the ways to contact your supplier and pay. PurityMap does not take payments.