Perfluorooctanoic acid
7.5ng/L
Each block = 4.0 ng/L federal MCL (2024)
Short answer: Two PFAS, PFOA and PFOS, are above their federal limits (2024 limits that water systems have until at least 2029 to meet); lithium sits above a screening level. Monroe Municipal Utilities Authority serves 26,179 residents.
Your water bill or annual water quality report names your actual supplier.
Each bar is drawn in blocks of the 4.0 ng/L federal MCL (2024), so the length shows how far above it the result sits.
7.5ng/L
Each block = 4.0 ng/L federal MCL (2024)
4.2ng/L
Each block = 4.0 ng/L federal MCL (2024)
MONROE MUNICIPAL UTILITIES AUTHORITY (EPA PWSID NJ0811002) delivers surface water to 26,179 residents. This report reflects 29 individual PFAS result(s) from the source UCMR5 observations and the latest Lead & Copper Rule 90th-percentile result. Water hardness and disinfectant type are pending the utility's own annual report.
0health-based violations in the last 10 years
From EPA SDWIS. A clean violation history means no enforcement action was recorded; it does not cover contaminants without a limit.
No result is not a pass. Your utility's annual water quality report may list them, and a certified lab test covers your own tap.
Plumbing inside a home can add lead that the system record can't show. A tap test tells you what reaches your glass.
PFOA 7.5 ng/L, above the 4 ng/L limit (+2 more PFAS detected)
lead 1.98 µg/L, below the 15 µg/L action level (detected below the limit); 23 galvanized lines to replace (context, not a tap measurement)
Screening tells you if something is worth a closer look; a lab result is the number you can act on.
As an Amazon Associate, PurityMap earns from qualifying purchases. Affiliate disclosure.
Screening: quick check, not lab-grade
Safe Home (EnviroTestKits)
Lead, read as one of three ranges: 0–4, 5–15 or 15+ ppb
What it can't tell you: It shows a lead range, not an exact level, and tests nothing else unless you pay extra for the optional lab test.
Lab-certified results
ETR Laboratories
50+ substances, including lead, copper, arsenic, nitrate, hardness and coliform bacteria
What it can't tell you: It does not test PFAS, and not every result on the panel falls under the lab's accredited scope.
When your results arrive, read them here →
Each card names which Williamstown findings its current certification covers, and which it doesn't.
As an Amazon Associate, PurityMap earns from qualifying purchases. A product appears here only when a current certification record covers at least one identified concern; every concern stays listed. The retail offer is looked up afterwards and never changes which products appear or their order. Affiliate disclosure.













PurityMap does not give a safe/unsafe verdict; it shows what the public records measured. For Williamstown, PFOA 7.5 ng/L and PFOS 4.2 ng/L were measured above the 4 ng/L federal limit in EPA's 2024 testing; the lead 90th-percentile result was 1.98 µg/L against the 15 µg/L action level. MONROE MUNICIPAL UTILITIES AUTHORITY (PWSID NJ0811002) has a Purity Score of 58/100 (confidence: moderate), assessed at the water-system level and computed only from contaminants that were measured. Water can change in your own pipes, so a certified test is the only way to know what comes out of your tap.
MONROE MUNICIPAL UTILITIES AUTHORITY (PWS ID NJ0811002) is the public water system on record for Williamstown, New Jersey, serving about 26,179 people. Confirm the utility on your water bill before acting on a specific finding.
Surface water (primary source of record in EPA SDWIS).
Yes. In EPA's UCMR 5 testing (2024-04-02 to 2025-01-08), PFOA was measured at 7.5 ng/L against a 4 ng/L federal limit and PFOS was measured at 4.2 ng/L against a 4 ng/L federal limit. PFHxA (3.2 ng/L, below the 400,000 ng/L state limit) was also detected. Reverse osmosis and filters certified to NSF/ANSI 53 for PFOA/PFOS reduce them at the tap.
MONROE MUNICIPAL UTILITIES AUTHORITY's most recent lead 90th-percentile result (2024–2026) was 1.98 µg/L, below the 15 µg/L action level. That figure comes from sampled homes; lead usually enters from a building's own pipes and fixtures, so only a test at your tap tells you what you drink.
PurityMap's current record for Williamstown holds 31 findings: 3 above a reference, 2 detected within the reference and 26 not detected. Each finding links to its dated public record; a parameter that was never monitored is shown as pending, not as a pass.
Follow Williamstown's water
One email when a new sampling round is published, a result moves above or below its reference, or the system's score changes.
Double opt-in: we email a confirmation link. Unsubscribe anytime. No spam.
| Contaminant | Result | Benchmark | Status | Sampled | Source |
|---|---|---|---|---|---|
| Perfluorooctanoic acid (PFOA) | 7.5 ng/L | 4.0 ng/L federal MCL (2024) | Above a historical reference; current applicability unverified | 2024-04-02 to 2025-01-08 | UCMR5 Analytical Results: MONROE MUNICIPAL UTILITIES AUTHORITY (NJ0811002) |
| Lithium | 12.1 µg/L | 10 µg/L EPA health reference level (screening, not a legal limit)Screening level, not a legal limit | Above the referenced health-based guidance value | 2024-04-02 to 2025-01-08 | UCMR5 Analytical Results: MONROE MUNICIPAL UTILITIES AUTHORITY (NJ0811002) |
| Perfluorooctanesulfonic acid (PFOS) | 4.2 ng/L | 4.0 ng/L federal MCL (2024) | Above a historical reference; current applicability unverified | 2024-04-02 to 2025-01-08 | UCMR5 Analytical Results: MONROE MUNICIPAL UTILITIES AUTHORITY (NJ0811002) |
| Lead (90th percentile) | 1.98 µg/L | 15 µg/L federal action level | Below the listed reference | 2024–2026 monitoring period (still open) | Lead & Copper Rule 90th-percentile: MONROE MUNICIPAL UTILITIES AUTHORITY (NJ0811002) |
| Perfluorohexanoic acid (PFHxA) | 3.2 ng/L | 400,000 ng/L Michigan EGLE state MCL (strictest US state) | Within a historical reference; current applicability unverified | 2024-04-02 to 2025-01-08 | UCMR5 Analytical Results: MONROE MUNICIPAL UTILITIES AUTHORITY (NJ0811002) |
| Contaminant | Result | Benchmark | Status | Sampled | Source |
|---|---|---|---|---|---|
| 11-Chloroeicosafluoro-3-oxaundecane-1-sulfonic acid (11Cl-PF3OUdS) | < 5 ng/L | No federal or state limit; shown for transparency | Not detected above the reporting limit | 2024-04-02 to 2025-01-08 | UCMR5 Analytical Results: MONROE MUNICIPAL UTILITIES AUTHORITY (NJ0811002) |
| 1H, 1H, 2H, 2H-perfluorodecane sulfonic acid (8:2 FTS) | < 5 ng/L | No federal or state limit; shown for transparency | Not detected above the reporting limit | 2024-04-02 to 2025-01-08 | UCMR5 Analytical Results: MONROE MUNICIPAL UTILITIES AUTHORITY (NJ0811002) |
| 1H, 1H, 2H, 2H-perfluorohexane sulfonic acid (4:2 FTS) | < 3 ng/L | No federal or state limit; shown for transparency | Not detected above the reporting limit | 2024-04-02 to 2025-01-08 | UCMR5 Analytical Results: MONROE MUNICIPAL UTILITIES AUTHORITY (NJ0811002) |
| 1H, 1H, 2H, 2H-perfluorooctane sulfonic acid (6:2 FTS) | < 5 ng/L | No federal or state limit; shown for transparency | Not detected above the reporting limit | 2024-04-02 to 2025-01-08 | UCMR5 Analytical Results: MONROE MUNICIPAL UTILITIES AUTHORITY (NJ0811002) |
| 4,8-Dioxa-3H-perfluorononanoic acid (ADONA) | < 3 ng/L | No federal or state limit; shown for transparency | Not detected above the reporting limit | 2024-04-02 to 2025-01-08 | UCMR5 Analytical Results: MONROE MUNICIPAL UTILITIES AUTHORITY (NJ0811002) |
| 9-Chlorohexadecafluoro-3-oxanone-1-sulfonic acid (9Cl-PF3ONS) | < 2 ng/L | No federal or state limit; shown for transparency | Not detected above the reporting limit | 2024-04-02 to 2025-01-08 | UCMR5 Analytical Results: MONROE MUNICIPAL UTILITIES AUTHORITY (NJ0811002) |
| Hexafluoropropylene oxide dimer acid (HFPO-DA) (GenX chemicals) | < 5 ng/L | 10 ng/L federal MCL (2024) | Not detected above the reporting limit | 2024-04-02 to 2025-01-08 | UCMR5 Analytical Results: MONROE MUNICIPAL UTILITIES AUTHORITY (NJ0811002) |
| N-ethyl perfluorooctanesulfonamidoacetic acid (NEtFOSAA) | < 5 ng/L | No federal or state limit; shown for transparency | Not detected above the reporting limit | 2024-04-02 to 2025-01-08 | UCMR5 Analytical Results: MONROE MUNICIPAL UTILITIES AUTHORITY (NJ0811002) |
| N-methyl perfluorooctanesulfonamidoacetic acid (NMeFOSAA) | < 6 ng/L | No federal or state limit; shown for transparency | Not detected above the reporting limit | 2024-04-02 to 2025-01-08 | UCMR5 Analytical Results: MONROE MUNICIPAL UTILITIES AUTHORITY (NJ0811002) |
| Nonafluoro-3,6-dioxaheptanoic acid (NFDHA) | < 20 ng/L | No federal or state limit; shown for transparency | Not detected above the reporting limit | 2024-04-02 to 2025-01-08 | UCMR5 Analytical Results: MONROE MUNICIPAL UTILITIES AUTHORITY (NJ0811002) |
| Perfluoro (2-ethoxyethane) sulfonic acid (PFEESA) | < 3 ng/L | No federal or state limit; shown for transparency | Not detected above the reporting limit | 2024-04-02 to 2025-01-08 | UCMR5 Analytical Results: MONROE MUNICIPAL UTILITIES AUTHORITY (NJ0811002) |
| Perfluoro-3-methoxypropanoic acid (PFMPA) | < 4 ng/L | No federal or state limit; shown for transparency | Not detected above the reporting limit | 2024-04-02 to 2025-01-08 | UCMR5 Analytical Results: MONROE MUNICIPAL UTILITIES AUTHORITY (NJ0811002) |
| Perfluoro-4-methoxybutanoic acid (PFMBA) | < 3 ng/L | No federal or state limit; shown for transparency | Not detected above the reporting limit | 2024-04-02 to 2025-01-08 | UCMR5 Analytical Results: MONROE MUNICIPAL UTILITIES AUTHORITY (NJ0811002) |
| Perfluorobutanesulfonic acid (PFBS) | < 3 ng/L | 2,000 ng/L EPA health advisory (screening, not a legal limit)Screening level, not a legal limit | Not detected above the reporting limit | 2024-04-02 to 2025-01-08 | UCMR5 Analytical Results: MONROE MUNICIPAL UTILITIES AUTHORITY (NJ0811002) |
| Perfluorobutanoic acid (PFBA) | < 5 ng/L | No federal or state limit; shown for transparency | Not detected above the reporting limit | 2024-04-02 to 2025-01-08 | UCMR5 Analytical Results: MONROE MUNICIPAL UTILITIES AUTHORITY (NJ0811002) |
| Perfluorodecanoic acid (PFDA) | < 3 ng/L | No federal or state limit; shown for transparency | Not detected above the reporting limit | 2024-04-02 to 2025-01-08 | UCMR5 Analytical Results: MONROE MUNICIPAL UTILITIES AUTHORITY (NJ0811002) |
| Perfluorododecanoic acid (PFDoA) | < 3 ng/L | No federal or state limit; shown for transparency | Not detected above the reporting limit | 2024-04-02 to 2025-01-08 | UCMR5 Analytical Results: MONROE MUNICIPAL UTILITIES AUTHORITY (NJ0811002) |
| Perfluoroheptanesulfonic acid (PFHpS) | < 3 ng/L | No federal or state limit; shown for transparency | Not detected above the reporting limit | 2024-04-02 to 2025-01-08 | UCMR5 Analytical Results: MONROE MUNICIPAL UTILITIES AUTHORITY (NJ0811002) |
| Perfluoroheptanoic acid (PFHpA) | < 3 ng/L | No federal or state limit; shown for transparency | Not detected above the reporting limit | 2024-04-02 to 2025-01-08 | UCMR5 Analytical Results: MONROE MUNICIPAL UTILITIES AUTHORITY (NJ0811002) |
| Perfluorohexanesulfonic acid (PFHxS) | < 3 ng/L | 10 ng/L federal MCL (2024) | Not detected above the reporting limit | 2024-04-02 to 2025-01-08 | UCMR5 Analytical Results: MONROE MUNICIPAL UTILITIES AUTHORITY (NJ0811002) |
| Perfluorononanoic acid (PFNA) | < 4 ng/L | 10 ng/L federal MCL (2024) | Not detected above the reporting limit | 2024-04-02 to 2025-01-08 | UCMR5 Analytical Results: MONROE MUNICIPAL UTILITIES AUTHORITY (NJ0811002) |
| Perfluoropentanesulfonic acid (PFPeS) | < 4 ng/L | No federal or state limit; shown for transparency | Not detected above the reporting limit | 2024-04-02 to 2025-01-08 | UCMR5 Analytical Results: MONROE MUNICIPAL UTILITIES AUTHORITY (NJ0811002) |
| Perfluoropentanoic acid (PFPeA) | < 3 ng/L | No federal or state limit; shown for transparency | Not detected above the reporting limit | 2024-04-02 to 2025-01-08 | UCMR5 Analytical Results: MONROE MUNICIPAL UTILITIES AUTHORITY (NJ0811002) |
| Perfluorotetradecanoic acid (PFTA) | < 8 ng/L | No federal or state limit; shown for transparency | Not detected above the reporting limit | 2024-04-02 to 2025-01-08 | UCMR5 Analytical Results: MONROE MUNICIPAL UTILITIES AUTHORITY (NJ0811002) |
| Perfluorotridecanoic acid (PFTrDA) | < 7 ng/L | No federal or state limit; shown for transparency | Not detected above the reporting limit | 2024-04-02 to 2025-01-08 | UCMR5 Analytical Results: MONROE MUNICIPAL UTILITIES AUTHORITY (NJ0811002) |
| Perfluoroundecanoic acid (PFUnA) | < 2 ng/L | No federal or state limit; shown for transparency | Not detected above the reporting limit | 2024-04-02 to 2025-01-08 | UCMR5 Analytical Results: MONROE MUNICIPAL UTILITIES AUTHORITY (NJ0811002) |
Perfluorooctanesulfonic acid (PFOS)
Perfluorohexanoic acid (PFHxA)
11-Chloroeicosafluoro-3-oxaundecane-1-sulfonic acid (11Cl-PF3OUdS)
1H, 1H, 2H, 2H-perfluorodecane sulfonic acid (8:2 FTS)
1H, 1H, 2H, 2H-perfluorohexane sulfonic acid (4:2 FTS)
1H, 1H, 2H, 2H-perfluorooctane sulfonic acid (6:2 FTS)
4,8-Dioxa-3H-perfluorononanoic acid (ADONA)
9-Chlorohexadecafluoro-3-oxanone-1-sulfonic acid (9Cl-PF3ONS)
Hexafluoropropylene oxide dimer acid (HFPO-DA) (GenX chemicals)
N-ethyl perfluorooctanesulfonamidoacetic acid (NEtFOSAA)
N-methyl perfluorooctanesulfonamidoacetic acid (NMeFOSAA)
Nonafluoro-3,6-dioxaheptanoic acid (NFDHA)
Perfluoro (2-ethoxyethane) sulfonic acid (PFEESA)
Perfluoro-3-methoxypropanoic acid (PFMPA)
Perfluoro-4-methoxybutanoic acid (PFMBA)
Perfluorobutanesulfonic acid (PFBS)
Perfluorododecanoic acid (PFDoA)
Perfluoroheptanesulfonic acid (PFHpS)
Perfluoroheptanoic acid (PFHpA)
Perfluorohexanesulfonic acid (PFHxS)
Perfluoropentanesulfonic acid (PFPeS)
Perfluoropentanoic acid (PFPeA)
Perfluorotetradecanoic acid (PFTA)
Perfluorotridecanoic acid (PFTrDA)
Perfluoroundecanoic acid (PFUnA)
Every value is the published result from the cited public record. A reporting limit is the lowest level the method could reliably quantify; a non-detect is not a guarantee of zero.
UCMR5 Analytical Results
UCMR5 Analytical Results: MONROE MUNICIPAL UTILITIES AUTHORITY (NJ0811002)
US EPA
State SDWIS Compliance Record
Lead & Copper Rule 90th-percentile: MONROE MUNICIPAL UTILITIES AUTHORITY (NJ0811002)
US EPA SDWIS
Methodology: how we analyze water. Prepared with AI assistance and reviewed by the PurityMap Editorial Team before publication.
Start with the hot-or-cold tap check. Where Monroe Municipal Utilities Authority reported something related, it's shown below.
Lead at Monroe Municipal Utilities Authority: 1.98 µg/L (90th percentile, 2024–2026 monitoring period (still open)). Lead has no taste, so a taste neither shows nor rules it out.
A ZIP code is a postal area, not a water service area. Your water bill names your supplier.