Forensic evidence record · ev-ca1910152-f-south-gate-pfpea
Perfluoropentanoic acid (PFPeA)
A single published measurement record with its qualifier, sampling context, source identifier, method note, and stated limitations kept together.
Published evidence record
6.3 ng/LReported measurementSource observations (10)
- PFPeA — Sample date: 2023-03-08
Below reporting limit. < Result value not available µg/L
Reporting limit: 0.003 µg/L. Detection limit: Not available. Benchmark unavailable
Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 3C07106-09 · Method EPA 533
- PFPeA — Sample date: 2023-09-13
Below reporting limit. < Result value not available µg/L
Reporting limit: 0.003 µg/L. Detection limit: Not available. Benchmark unavailable
Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 3I12004-09 · Method EPA 533
- PFPeA — Sample date: 2023-03-08
Detected above reporting limit. = 0.0032 µg/L
Reporting limit: 0.003 µg/L. Detection limit: Not available. Benchmark unavailable
Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 3C07106-01 · Method EPA 533
- PFPeA — Sample date: 2024-01-17
Detected above reporting limit. = 0.0036 µg/L
Reporting limit: 0.003 µg/L. Detection limit: Not available. Benchmark unavailable
Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 4A15005-01 · Method EPA 533
- PFPeA — Sample date: 2023-03-08
Below reporting limit. < Result value not available µg/L
Reporting limit: 0.003 µg/L. Detection limit: Not available. Benchmark unavailable
Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 3C07106-03 · Method EPA 533
- PFPeA — Sample date: 2023-10-11
Below reporting limit. < Result value not available µg/L
Reporting limit: 0.003 µg/L. Detection limit: Not available. Benchmark unavailable
Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 3J09008-01 · Method EPA 533
- PFPeA — Sample date: 2023-03-08
Detected above reporting limit. = 0.0056 µg/L
Reporting limit: 0.003 µg/L. Detection limit: Not available. Benchmark unavailable
Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 3C07106-05 · Method EPA 533
- PFPeA — Sample date: 2023-09-13
Detected above reporting limit. = 0.0063 µg/L
Reporting limit: 0.003 µg/L. Detection limit: Not available. Benchmark unavailable
Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 3I12004-05 · Method EPA 533
- PFPeA — Sample date: 2023-05-10
Below reporting limit. < Result value not available µg/L
Reporting limit: 0.003 µg/L. Detection limit: Not available. Benchmark unavailable
Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 3E08009-01 · Method EPA 533
- PFPeA — Sample date: 2023-11-22
Below reporting limit. < Result value not available µg/L
Reporting limit: 0.003 µg/L. Detection limit: Not available. Benchmark unavailable
Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 3K20014-01RE1 · Method EPA 533
Measurement evidence
- Analyte
- Perfluoropentanoic acid (PFPeA)
- Result qualifier
- =
- Reference basis
- No federal or state limit; shown for transparency
- Sampling location
- Entry Point to Distribution
- Water system ID
- CA1910152
- Source ID
- src-ucmr5-2024
Laboratory context
No laboratory method note was published with this record.
Sampling context
This result represents a entry point to distribution sample. It does not establish the condition at every distribution point or household tap.
Record limitation
System-level entry-point monitoring; not a measurement of the water at an individual household tap.
Source provenance
UCMR5 Analytical Results
Fifth Unregulated Contaminant Monitoring Rule (UCMR5) — PFAS occurrence data
U.S. Environmental Protection Agency · Published 2024
Nationwide entry-point monitoring for 29 PFAS and lithium under the fifth UCMR cycle. Results are entry-point-to-distribution samples, not household-tap measurements.
How to interpret this record
This page preserves one measurement. Interpretation requires its qualifier, reporting limit, reference basis, date, sampling location, and limitations; the number alone is not a safety verdict.