Forensic evidence record · ev-ca3010037-f-yorba-linda-district-lithium
Lithium
A single published measurement record with its qualifier, sampling context, source identifier, method note, and stated limitations kept together.
Published evidence record
36.38 µg/LReported measurementSource observations (10)
- lithium — Sample date: 2023-03-14
Below reporting limit. < Result value not available µg/L
Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable
Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 23030475-04 · Method EPA 200.7
- lithium — Sample date: 2023-06-21
Detected above reporting limit. = 20.9337 µg/L
Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable
Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 23060614-04 · Method EPA 200.7
- lithium — Sample date: 2023-09-13
Detected above reporting limit. = 36.3421 µg/L
Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable
Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 23090372-04 · Method EPA 200.7
- lithium — Sample date: 2023-12-06
Detected above reporting limit. = 32.788 µg/L
Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable
Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 23002532-04 · Method EPA 200.7
- lithium — Sample date: 2023-03-14
Below reporting limit. < Result value not available µg/L
Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable
Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 23030439-04 · Method EPA 200.7
- lithium — Sample date: 2023-06-21
Detected above reporting limit. = 19.651 µg/L
Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable
Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 23060578-04 · Method EPA 200.7
- lithium — Sample date: 2023-09-13
Detected above reporting limit. = 36.3779 µg/L
Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable
Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 23090336-04 · Method EPA 200.7
- lithium — Sample date: 2023-12-06
Detected above reporting limit. = 30.6176 µg/L
Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable
Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 23002496-04 · Method EPA 200.7
- lithium — Sample date: 2023-11-21
Detected above reporting limit. = 9.9473 µg/L
Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable
Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 23002105-04 · Method EPA 200.7
- lithium — Sample date: 2024-05-21
Detected above reporting limit. = 9.8561 µg/L
Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable
Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 24005229-04 · Method EPA 200.7
Measurement evidence
- Analyte
- Lithium
- Result qualifier
- =
- Reference basis
- 10.0 µg/L EPA health reference level (screening, not a legal limit)
- Sampling location
- Entry Point to Distribution
- Water system ID
- CA3010037
- Source ID
- src-ucmr5-2024
Laboratory context
No laboratory method note was published with this record.
Sampling context
This result represents a entry point to distribution sample. It does not establish the condition at every distribution point or household tap.
Record limitation
System-level entry-point monitoring; not a measurement of the water at an individual household tap.
Source provenance
UCMR5 Analytical Results
Fifth Unregulated Contaminant Monitoring Rule (UCMR5) — PFAS occurrence data
U.S. Environmental Protection Agency · Published 2024
Nationwide entry-point monitoring for 29 PFAS and lithium under the fifth UCMR cycle. Results are entry-point-to-distribution samples, not household-tap measurements.
How to interpret this record
This page preserves one measurement. Interpretation requires its qualifier, reporting limit, reference basis, date, sampling location, and limitations; the number alone is not a safety verdict.
Review finding states →