Forensic evidence record · ev-ca3610014-f-colton-pfoa

Perfluorooctanoic acid (PFOA)

A single published measurement record with its qualifier, sampling context, source identifier, method note, and stated limitations kept together.

Published evidence record

5.9 ng/LReported measurement
Back to water-system profile
5.9 ng/Lreported result
Not verified from sourcereporting limit
Sample date: 2023-07-25 to 2025-02-27sample date
2026-01-15publication date
Source observations (15)
  • PFOA — Sample date: 2023-09-13

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 0.004 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample C3I1597-01 · Method EPA 533

  • PFOA — Sample date: 2024-01-23

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 0.004 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample C4A3077-01 · Method EPA 533

  • PFOA — Sample date: 2023-07-25

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 0.004 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample C3G3217-03 · Method EPA 533

  • PFOA — Sample date: 2025-01-28

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 0.004 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample C5A3121-01RE1 · Method EPA 533

  • PFOA — Sample date: 2023-07-25

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 0.004 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample C3G3217-05 · Method EPA 533

  • PFOA — Sample date: 2024-01-23

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 0.004 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample C4A3077-03 · Method EPA 533

  • PFOA — Sample date: 2023-07-25

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 0.004 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample C3G3217-07 · Method EPA 533

  • PFOA — Sample date: 2024-01-23

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 0.004 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample C4A3077-05 · Method EPA 533

  • PFOA — Sample date: 2023-08-30

    Detected above reporting limit. = 0.0059 µg/L

    Reporting limit: 0.004 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample C3H4082-01 · Method EPA 533

  • PFOA — Sample date: 2023-07-25

    Detected above reporting limit. = 0.0045 µg/L

    Reporting limit: 0.004 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample C3G3217-09 · Method EPA 533

  • PFOA — Sample date: 2024-01-29

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 0.004 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample C4A3829-01 · Method EPA 533

  • PFOA — Sample date: 2023-07-25

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 0.004 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample C3G3217-11 · Method EPA 533

  • PFOA — Sample date: 2025-02-27

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 0.004 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample C5B3449-01 · Method EPA 533

  • PFOA — Sample date: 2023-07-25

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 0.004 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample C3G3217-13 · Method EPA 533

  • PFOA — Sample date: 2024-01-23

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 0.004 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample C4A3077-09 · Method EPA 533

Measurement evidence

Analyte
Perfluorooctanoic acid (PFOA)
Result qualifier
=
Reference basis
4.0 ng/L federal MCL (2024)
Sampling location
Entry Point to Distribution
Water system ID
CA3610014
Source ID
src-ucmr5-2024

Laboratory context

No laboratory method note was published with this record.

Sampling context

This result represents a entry point to distribution sample. It does not establish the condition at every distribution point or household tap.

Record limitation

System-level entry-point monitoring; not a measurement of the water at an individual household tap.

Source provenance

UCMR5 Analytical Results

Fifth Unregulated Contaminant Monitoring Rule (UCMR5) — PFAS occurrence data

U.S. Environmental Protection Agency · Published 2024

Nationwide entry-point monitoring for 29 PFAS and lithium under the fifth UCMR cycle. Results are entry-point-to-distribution samples, not household-tap measurements.

How to interpret this record

This page preserves one measurement. Interpretation requires its qualifier, reporting limit, reference basis, date, sampling location, and limitations; the number alone is not a safety verdict.

Review finding states →