Forensic evidence record · ev-ca4210001-f-carpinteria-valley-district-lithium
Lithium
A single published measurement record with its qualifier, sampling context, source identifier, method note, and stated limitations kept together.
Published evidence record
37.3 µg/LReported measurementSource observations (9)
- lithium — Sample date: 2023-05-03
Detected above reporting limit. = 22.2 µg/L
Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable
Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 380-46294-1 · Method EPA 200.7
- lithium — Sample date: 2023-11-07
Detected above reporting limit. = 25.7 µg/L
Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable
Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 380-70402-1 · Method EPA 200.7
- lithium — Sample date: 2023-05-03
Detected above reporting limit. = 27.3 µg/L
Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable
Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 380-46294-2 · Method EPA 200.7
- lithium — Sample date: 2023-11-07
Detected above reporting limit. = 25.7 µg/L
Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable
Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 380-70402-2 · Method EPA 200.7
- lithium — Sample date: 2023-05-03
Detected above reporting limit. = 16.7 µg/L
Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable
Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 380-46294-3 · Method EPA 200.7
- lithium — Sample date: 2023-11-07
Detected above reporting limit. = 26.5 µg/L
Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable
Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 380-70402-3 · Method EPA 200.7
- lithium — Sample date: 2023-05-03
Detected above reporting limit. = 37.3 µg/L
Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable
Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 380-46293-2 · Method EPA 200.7
- lithium — Sample date: 2023-08-14
Detected above reporting limit. = 23.9 µg/L
Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable
Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 380-59099-1 · Method EPA 200.7
- lithium — Sample date: 2024-02-06
Detected above reporting limit. = 27.2 µg/L
Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable
Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 380-82043-1 · Method EPA 200.7
Measurement evidence
- Analyte
- Lithium
- Result qualifier
- =
- Reference basis
- 10.0 µg/L EPA health reference level (screening, not a legal limit)
- Sampling location
- Entry Point to Distribution
- Water system ID
- CA4210001
- Source ID
- src-ucmr5-2024
Laboratory context
No laboratory method note was published with this record.
Sampling context
This result represents a entry point to distribution sample. It does not establish the condition at every distribution point or household tap.
Record limitation
System-level entry-point monitoring; not a measurement of the water at an individual household tap.
Source provenance
UCMR5 Analytical Results
Fifth Unregulated Contaminant Monitoring Rule (UCMR5) — PFAS occurrence data
U.S. Environmental Protection Agency · Published 2024
Nationwide entry-point monitoring for 29 PFAS and lithium under the fifth UCMR cycle. Results are entry-point-to-distribution samples, not household-tap measurements.
How to interpret this record
This page preserves one measurement. Interpretation requires its qualifier, reporting limit, reference basis, date, sampling location, and limitations; the number alone is not a safety verdict.