Forensic evidence record · ev-co0118025-f-pinery-wwd-lithium

Lithium

A single published measurement record with its qualifier, sampling context, source identifier, method note, and stated limitations kept together.

Published evidence record

29.5 µg/LReported measurement
Back to water-system profile
29.5 µg/Lreported result
Not verified from sourcereporting limit
Sample date: 2024-05-29 to 2025-04-09sample date
2026-01-15publication date
Source observations (14)
  • lithium — Sample date: 2024-05-29

    Detected above reporting limit. = 22.9 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 810-106392-1 · Method EPA 200.7

  • lithium — Sample date: 2024-08-21

    Detected above reporting limit. = 25.3 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 810-117369-1 · Method EPA 200.7

  • lithium — Sample date: 2024-10-02

    Detected above reporting limit. = 27.1 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 810-122974-1 · Method EPA 200.7

  • lithium — Sample date: 2025-04-09

    Detected above reporting limit. = 22.1 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 810-144138-1 · Method EPA 200.7

  • lithium — Sample date: 2024-05-29

    Detected above reporting limit. = 16.5 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 810-106387-1 · Method EPA 200.7

  • lithium — Sample date: 2024-11-11

    Detected above reporting limit. = 15.8 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 810-127581-1 · Method EPA 200.7

  • lithium — Sample date: 2024-05-29

    Detected above reporting limit. = 27.4 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 810-106458-1 · Method EPA 200.7

  • lithium — Sample date: 2024-10-02

    Detected above reporting limit. = 29.5 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 810-122951-1 · Method EPA 200.7

  • lithium — Sample date: 2024-05-29

    Detected above reporting limit. = 20.9 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 810-106397-1 · Method EPA 200.7

  • lithium — Sample date: 2024-10-02

    Detected above reporting limit. = 24.3 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 810-122972-1 · Method EPA 200.7

  • lithium — Sample date: 2024-05-29

    Detected above reporting limit. = 23.9 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 810-106382-1 · Method EPA 200.7

  • lithium — Sample date: 2024-11-11

    Detected above reporting limit. = 22.7 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 810-127583-1 · Method EPA 200.7

  • lithium — Sample date: 2024-05-29

    Detected above reporting limit. = 25.7 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 810-106363-1 · Method EPA 200.7

  • lithium — Sample date: 2024-10-02

    Detected above reporting limit. = 28.8 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 810-122958-1 · Method EPA 200.7

Measurement evidence

Analyte
Lithium
Result qualifier
=
Reference basis
10.0 µg/L EPA health reference level (screening, not a legal limit)
Sampling location
Entry Point to Distribution
Water system ID
CO0118025
Source ID
src-ucmr5-2024

Laboratory context

No laboratory method note was published with this record.

Sampling context

This result represents a entry point to distribution sample. It does not establish the condition at every distribution point or household tap.

Record limitation

System-level entry-point monitoring; not a measurement of the water at an individual household tap.

Source provenance

UCMR5 Analytical Results

Fifth Unregulated Contaminant Monitoring Rule (UCMR5) — PFAS occurrence data

U.S. Environmental Protection Agency · Published 2024

Nationwide entry-point monitoring for 29 PFAS and lithium under the fifth UCMR cycle. Results are entry-point-to-distribution samples, not household-tap measurements.

How to interpret this record

This page preserves one measurement. Interpretation requires its qualifier, reporting limit, reference basis, date, sampling location, and limitations; the number alone is not a safety verdict.

Review finding states →