Forensic evidence record · ev-co0151650-f-pueblo-west-md-pfoa

Perfluorooctanoic acid (PFOA)

A single published measurement record with its qualifier, sampling context, source identifier, method note, and stated limitations kept together.

Published evidence record

Non-Detect (ND)Reported measurement
Back to water-system profile
Non-Detect (ND)reported result
4 ng/Lreporting limit
Sample date: 2023-02-09 to 2023-11-08sample date
2026-01-15publication date
Source observations (12)
  • PFOA — Sample date: 2023-02-21

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 0.004 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample K2302195-001 · Method EPA 533

  • PFOA — Sample date: 2023-05-31

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 0.004 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample K2306169-001 · Method EPA 533

  • PFOA — Sample date: 2023-08-08

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 0.004 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample K2308964-001 · Method EPA 533

  • PFOA — Sample date: 2023-11-08

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 0.004 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample K2312731-005 · Method EPA 533

  • PFOA — Sample date: 2023-02-09

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 0.004 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample K2301785-005 · Method EPA 533

  • PFOA — Sample date: 2023-05-31

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 0.004 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample K2306169-007 · Method EPA 533

  • PFOA — Sample date: 2023-08-08

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 0.004 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample K2308964-003 · Method EPA 533

  • PFOA — Sample date: 2023-11-08

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 0.004 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample K2312731-003 · Method EPA 533

  • PFOA — Sample date: 2023-02-09

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 0.004 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample K2301785-003 · Method EPA 533

  • PFOA — Sample date: 2023-05-31

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 0.004 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample K2306169-005 · Method EPA 533

  • PFOA — Sample date: 2023-08-08

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 0.004 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample K2308964-005 · Method EPA 533

  • PFOA — Sample date: 2023-11-08

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 0.004 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample K2312731-001 · Method EPA 533

Measurement evidence

Analyte
Perfluorooctanoic acid (PFOA)
Result qualifier
ND
Reference basis
4.0 ng/L federal MCL (2024)
Sampling location
Entry Point to Distribution
Water system ID
CO0151650
Source ID
src-ucmr5-2024

Laboratory context

No laboratory method note was published with this record.

Sampling context

This result represents a entry point to distribution sample. It does not establish the condition at every distribution point or household tap.

Record limitation

System-level entry-point monitoring; not a measurement of the water at an individual household tap.

Source provenance

UCMR5 Analytical Results

Fifth Unregulated Contaminant Monitoring Rule (UCMR5) — PFAS occurrence data

U.S. Environmental Protection Agency · Published 2024

Nationwide entry-point monitoring for 29 PFAS and lithium under the fifth UCMR cycle. Results are entry-point-to-distribution samples, not household-tap measurements.

How to interpret this record

This page preserves one measurement. Interpretation requires its qualifier, reporting limit, reference basis, date, sampling location, and limitations; the number alone is not a safety verdict.

Review finding states →

Related intelligence