Forensic evidence record · ev-ct0800011-f-meriden-pfbs

Perfluorobutanesulfonic acid (PFBS)

A single published measurement record with its qualifier, sampling context, source identifier, method note, and stated limitations kept together.

Published evidence record

3.7 ng/LReported measurement
Back to water-system profile
3.7 ng/Lreported result
Not verified from sourcereporting limit
Sample date: 2023-07-26 to 2024-04-30sample date
2026-01-15publication date
Source observations (19)
  • PFBS — Sample date: 2023-07-26

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 0.003 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 810-71475-1 · Method EPA 533

  • PFBS — Sample date: 2023-10-05

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 0.003 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 810-80564-1 · Method EPA 533

  • PFBS — Sample date: 2024-01-09

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 0.003 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 810-90087-1 · Method EPA 533

  • PFBS — Sample date: 2024-04-02

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 0.003 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 810-99198-1 · Method EPA 533

  • PFBS — Sample date: 2023-10-05

    Detected above reporting limit. = 0.0037 µg/L

    Reporting limit: 0.003 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 810-80565-1 · Method EPA 533

  • PFBS — Sample date: 2023-07-26

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 0.003 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 810-71476-1 · Method EPA 533

  • PFBS — Sample date: 2023-10-05

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 0.003 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 810-80560-1 · Method EPA 533

  • PFBS — Sample date: 2024-01-09

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 0.003 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 810-90082-1 · Method EPA 533

  • PFBS — Sample date: 2024-04-02

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 0.003 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 810-99206-1 · Method EPA 533

  • PFBS — Sample date: 2023-07-26

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 0.003 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 810-71477-1 · Method EPA 533

  • PFBS — Sample date: 2023-10-05

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 0.003 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 810-80555-1 · Method EPA 533

  • PFBS — Sample date: 2024-01-09

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 0.003 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 810-90084-1 · Method EPA 533

  • PFBS — Sample date: 2024-04-02

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 0.003 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 810-99200-1 · Method EPA 533

  • PFBS — Sample date: 2023-10-05

    Detected above reporting limit. = 0.0031 µg/L

    Reporting limit: 0.003 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 810-80570-1 · Method EPA 533

  • PFBS — Sample date: 2024-04-02

    Detected above reporting limit. = 0.0031 µg/L

    Reporting limit: 0.003 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 810-99230-1 · Method EPA 533

  • PFBS — Sample date: 2023-10-05

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 0.003 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 810-80575-1 · Method EPA 533

  • PFBS — Sample date: 2024-04-02

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 0.003 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 810-99235-1 · Method EPA 533

  • PFBS — Sample date: 2023-10-05

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 0.003 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 810-80566-1 · Method EPA 533

  • PFBS — Sample date: 2024-04-30

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 0.003 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 810-102709-1 · Method EPA 533

Measurement evidence

Analyte
Perfluorobutanesulfonic acid (PFBS)
Result qualifier
=
Reference basis
2000.0 ng/L EPA health advisory (screening, not a legal limit)
Sampling location
Entry Point to Distribution
Water system ID
CT0800011
Source ID
src-ucmr5-2024

Laboratory context

No laboratory method note was published with this record.

Sampling context

This result represents a entry point to distribution sample. It does not establish the condition at every distribution point or household tap.

Record limitation

System-level entry-point monitoring; not a measurement of the water at an individual household tap.

Source provenance

UCMR5 Analytical Results

Fifth Unregulated Contaminant Monitoring Rule (UCMR5) — PFAS occurrence data

U.S. Environmental Protection Agency · Published 2024

Nationwide entry-point monitoring for 29 PFAS and lithium under the fifth UCMR cycle. Results are entry-point-to-distribution samples, not household-tap measurements.

How to interpret this record

This page preserves one measurement. Interpretation requires its qualifier, reporting limit, reference basis, date, sampling location, and limitations; the number alone is not a safety verdict.

Review finding states →

Related intelligence