Published evidence record

21.2 µg/LReported measurement
Back to water-system profile
21.2 µg/Lreported result
Not verified from sourcereporting limit
Sample date: 2023-05-25 to 2024-02-06sample date
2026-01-15publication date
Source observations (12)
  • lithium — Sample date: 2023-05-25

    Detected above reporting limit. = 21.2 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 810-64522-1 · Method EPA 200.7

  • lithium — Sample date: 2023-11-06

    Detected above reporting limit. = 19.2 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 810-84032-1 · Method EPA 200.7

  • lithium — Sample date: 2023-05-25

    Detected above reporting limit. = 9.83 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 810-64497-1 · Method EPA 200.7

  • lithium — Sample date: 2023-11-06

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 810-84016-1 · Method EPA 200.7

  • lithium — Sample date: 2023-05-25

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 810-64527-1 · Method EPA 200.7

  • lithium — Sample date: 2023-08-22

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 810-74902-1 · Method EPA 200.7

  • lithium — Sample date: 2023-11-06

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 810-83979-1 · Method EPA 200.7

  • lithium — Sample date: 2024-02-06

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 810-92883-1 · Method EPA 200.7

  • lithium — Sample date: 2023-05-25

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 810-64530-1 · Method EPA 200.7

  • lithium — Sample date: 2023-08-22

    Detected above reporting limit. = 9.36 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 810-74905-1 · Method EPA 200.7

  • lithium — Sample date: 2023-11-06

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 810-84010-1 · Method EPA 200.7

  • lithium — Sample date: 2024-02-06

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 810-92905-1 · Method EPA 200.7

Measurement evidence

Analyte
Lithium
Result qualifier
=
Reference basis
10.0 µg/L EPA health reference level (screening, not a legal limit)
Sampling location
Entry Point to Distribution
Water system ID
NJ1209002
Source ID
src-ucmr5-2024

Laboratory context

No laboratory method note was published with this record.

Sampling context

This result represents a entry point to distribution sample. It does not establish the condition at every distribution point or household tap.

Record limitation

System-level entry-point monitoring; not a measurement of the water at an individual household tap.

Source provenance

UCMR5 Analytical Results

Fifth Unregulated Contaminant Monitoring Rule (UCMR5) — PFAS occurrence data

U.S. Environmental Protection Agency · Published 2024

Nationwide entry-point monitoring for 29 PFAS and lithium under the fifth UCMR cycle. Results are entry-point-to-distribution samples, not household-tap measurements.

How to interpret this record

This page preserves one measurement. Interpretation requires its qualifier, reporting limit, reference basis, date, sampling location, and limitations; the number alone is not a safety verdict.

Review finding states →