Forensic evidence record · ev-pa1090082-f-quakertown-boro-lithium

Lithium

A single published measurement record with its qualifier, sampling context, source identifier, method note, and stated limitations kept together.

Published evidence record

80.4 µg/LReported measurement
Back to water-system profile
80.4 µg/Lreported result
Not verified from sourcereporting limit
Sample date: 2025-02-12 to 2025-09-04sample date
2026-01-15publication date
Source observations (16)
  • lithium — Sample date: 2025-02-12

    Detected above reporting limit. = 16.7 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample M5A0798-01 · Method EPA 200.7

  • lithium — Sample date: 2025-09-02

    Detected above reporting limit. = 16.4 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample M5I0119-01 · Method EPA 200.7

  • lithium — Sample date: 2025-02-12

    Detected above reporting limit. = 21.1 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample M5A0798-03 · Method EPA 200.7

  • lithium — Sample date: 2025-09-04

    Detected above reporting limit. = 73.1 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample M5I0422-01 · Method EPA 200.7

  • lithium — Sample date: 2025-02-12

    Detected above reporting limit. = 21.8 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample M5A0798-05 · Method EPA 200.7

  • lithium — Sample date: 2025-09-02

    Detected above reporting limit. = 20.6 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample M5I0119-03 · Method EPA 200.7

  • lithium — Sample date: 2025-02-12

    Detected above reporting limit. = 17.8 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample M5A0798-07 · Method EPA 200.7

  • lithium — Sample date: 2025-08-05

    Detected above reporting limit. = 14.2 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample M5G0774-07 · Method EPA 200.7

  • lithium — Sample date: 2025-02-12

    Detected above reporting limit. = 80.4 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample M5A0798-09 · Method EPA 200.7

  • lithium — Sample date: 2025-09-04

    Detected above reporting limit. = 14.4 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample M5I0422-03 · Method EPA 200.7

  • lithium — Sample date: 2025-02-12

    Detected above reporting limit. = 16.6 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample M5A0798-11 · Method EPA 200.7

  • lithium — Sample date: 2025-08-05

    Detected above reporting limit. = 18.3 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample M5G0774-11 · Method EPA 200.7

  • lithium — Sample date: 2025-02-12

    Detected above reporting limit. = 15.9 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample M5A0798-13 · Method EPA 200.7

  • lithium — Sample date: 2025-08-05

    Detected above reporting limit. = 17.6 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample M5G0774-13 · Method EPA 200.7

  • lithium — Sample date: 2025-02-12

    Detected above reporting limit. = 16 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample M5A0798-15 · Method EPA 200.7

  • lithium — Sample date: 2025-08-05

    Detected above reporting limit. = 13.9 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample M5G0774-15 · Method EPA 200.7

Measurement evidence

Analyte
Lithium
Result qualifier
=
Reference basis
10.0 µg/L EPA health reference level (screening, not a legal limit)
Sampling location
Entry Point to Distribution
Water system ID
PA1090082
Source ID
src-ucmr5-2024

Laboratory context

No laboratory method note was published with this record.

Sampling context

This result represents a entry point to distribution sample. It does not establish the condition at every distribution point or household tap.

Record limitation

System-level entry-point monitoring; not a measurement of the water at an individual household tap.

Source provenance

UCMR5 Analytical Results

Fifth Unregulated Contaminant Monitoring Rule (UCMR5) — PFAS occurrence data

U.S. Environmental Protection Agency · Published 2024

Nationwide entry-point monitoring for 29 PFAS and lithium under the fifth UCMR cycle. Results are entry-point-to-distribution samples, not household-tap measurements.

How to interpret this record

This page preserves one measurement. Interpretation requires its qualifier, reporting limit, reference basis, date, sampling location, and limitations; the number alone is not a safety verdict.

Review finding states →