Forensic evidence record · ev-tx0610019-f-argyle-pfpea

Perfluoropentanoic acid (PFPeA)

A single published measurement record with its qualifier, sampling context, source identifier, method note, and stated limitations kept together.

Published evidence record

5.7 ng/LReported measurement
Back to water-system profile
5.7 ng/Lreported result
Not verified from sourcereporting limit
Sample date: 2023-02-21 to 2024-01-31sample date
2026-01-15publication date
Source observations (18)
  • PFPeA — Sample date: 2023-02-22

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 0.003 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 102719P · Method EPA 533

  • PFPeA — Sample date: 2023-08-14

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 0.003 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 107131P · Method EPA 533

  • PFPeA — Sample date: 2023-02-22

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 0.003 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 102720P · Method EPA 533

  • PFPeA — Sample date: 2023-08-14

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 0.003 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 107132P · Method EPA 533

  • PFPeA — Sample date: 2023-02-21

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 0.003 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 102721P · Method EPA 533

  • PFPeA — Sample date: 2023-08-14

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 0.003 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 107133P · Method EPA 533

  • PFPeA — Sample date: 2023-02-21

    Detected above reporting limit. = 0.0056 µg/L

    Reporting limit: 0.003 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 101263P · Method EPA 533

  • PFPeA — Sample date: 2023-08-14

    Detected above reporting limit. = 0.0057 µg/L

    Reporting limit: 0.003 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 107453R · Method EPA 533

  • PFPeA — Sample date: 2023-08-14

    Detected above reporting limit. = 0.0042 µg/L

    Reporting limit: 0.003 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 107134P · Method EPA 533

  • PFPeA — Sample date: 2024-01-31

    Detected above reporting limit. = 0.0049 µg/L

    Reporting limit: 0.003 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 113858R · Method EPA 533

  • PFPeA — Sample date: 2023-02-21

    Detected above reporting limit. = 0.0053 µg/L

    Reporting limit: 0.003 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 101264P · Method EPA 533

  • PFPeA — Sample date: 2023-06-05

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 0.003 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 105443R · Method EPA 533

  • PFPeA — Sample date: 2023-08-14

    Detected above reporting limit. = 0.0041 µg/L

    Reporting limit: 0.003 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 107135P · Method EPA 533

  • PFPeA — Sample date: 2023-11-14

    Detected above reporting limit. = 0.0056 µg/L

    Reporting limit: 0.003 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 110000P · Method EPA 533

  • PFPeA — Sample date: 2023-02-28

    Detected above reporting limit. = 0.0043 µg/L

    Reporting limit: 0.003 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 102717P · Method EPA 533

  • PFPeA — Sample date: 2023-06-05

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 0.003 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 105444R · Method EPA 533

  • PFPeA — Sample date: 2023-11-08

    Detected above reporting limit. = 0.0052 µg/L

    Reporting limit: 0.003 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 110415R · Method EPA 533

  • PFPeA — Sample date: 2023-11-14

    Detected above reporting limit. = 0.0054 µg/L

    Reporting limit: 0.003 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 110001P · Method EPA 533

Measurement evidence

Analyte
Perfluoropentanoic acid (PFPeA)
Result qualifier
=
Reference basis
No federal or state limit; shown for transparency
Sampling location
Entry Point to Distribution
Water system ID
TX0610019
Source ID
src-ucmr5-2024

Laboratory context

No laboratory method note was published with this record.

Sampling context

This result represents a entry point to distribution sample. It does not establish the condition at every distribution point or household tap.

Record limitation

System-level entry-point monitoring; not a measurement of the water at an individual household tap.

Source provenance

UCMR5 Analytical Results

Fifth Unregulated Contaminant Monitoring Rule (UCMR5) — PFAS occurrence data

U.S. Environmental Protection Agency · Published 2024

Nationwide entry-point monitoring for 29 PFAS and lithium under the fifth UCMR cycle. Results are entry-point-to-distribution samples, not household-tap measurements.

How to interpret this record

This page preserves one measurement. Interpretation requires its qualifier, reporting limit, reference basis, date, sampling location, and limitations; the number alone is not a safety verdict.

Review finding states →