Forensic evidence record · ev-tx1370001-f-kingsville-lithium

Lithium

A single published measurement record with its qualifier, sampling context, source identifier, method note, and stated limitations kept together.

Published evidence record

78 µg/LReported measurement
Back to water-system profile
78 µg/Lreported result
Not verified from sourcereporting limit
Sample date: 2023-03-28 to 2023-12-19sample date
2026-01-15publication date
Source observations (18)
  • lithium — Sample date: 2023-03-28

    Detected above reporting limit. = 40.1 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample Q2311370003 · Method EPA 200.7

  • lithium — Sample date: 2023-09-18

    Detected above reporting limit. = 48.2 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample Q2339927003 · Method EPA 200.7

  • lithium — Sample date: 2023-03-28

    Detected above reporting limit. = 44.2 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample Q2311370005 · Method EPA 200.7

  • lithium — Sample date: 2023-09-18

    Detected above reporting limit. = 55.5 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample Q2339927005 · Method EPA 200.7

  • lithium — Sample date: 2023-03-28

    Detected above reporting limit. = 50.5 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample Q2311370007 · Method EPA 200.7

  • lithium — Sample date: 2023-09-18

    Detected above reporting limit. = 59 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample Q2339927007 · Method EPA 200.7

  • lithium — Sample date: 2023-03-28

    Detected above reporting limit. = 43.2 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample Q2311370009 · Method EPA 200.7

  • lithium — Sample date: 2023-09-18

    Detected above reporting limit. = 56.6 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample Q2339927009 · Method EPA 200.7

  • lithium — Sample date: 2023-03-28

    Detected above reporting limit. = 14.2 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample Q2311370001 · Method EPA 200.7

  • lithium — Sample date: 2023-06-14

    Detected above reporting limit. = 11.7 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample Q2322711001 · Method EPA 200.7

  • lithium — Sample date: 2023-09-18

    Detected above reporting limit. = 16 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample Q2339927001 · Method EPA 200.7

  • lithium — Sample date: 2023-12-19

    Detected above reporting limit. = 20.1 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample Q2354095001 · Method EPA 200.7

  • lithium — Sample date: 2023-03-28

    Detected above reporting limit. = 52.2 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample Q2311370011 · Method EPA 200.7

  • lithium — Sample date: 2023-09-18

    Detected above reporting limit. = 57.1 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample Q2339927011 · Method EPA 200.7

  • lithium — Sample date: 2023-03-28

    Detected above reporting limit. = 60.7 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample Q2311370013 · Method EPA 200.7

  • lithium — Sample date: 2023-09-18

    Detected above reporting limit. = 73.3 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample Q2339927013 · Method EPA 200.7

  • lithium — Sample date: 2023-03-28

    Detected above reporting limit. = 62.5 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample Q2311370015 · Method EPA 200.7

  • lithium — Sample date: 2023-09-18

    Detected above reporting limit. = 78 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample Q2339927015 · Method EPA 200.7

Measurement evidence

Analyte
Lithium
Result qualifier
=
Reference basis
10.0 µg/L EPA health reference level (screening, not a legal limit)
Sampling location
Entry Point to Distribution
Water system ID
TX1370001
Source ID
src-ucmr5-2024

Laboratory context

No laboratory method note was published with this record.

Sampling context

This result represents a entry point to distribution sample. It does not establish the condition at every distribution point or household tap.

Record limitation

System-level entry-point monitoring; not a measurement of the water at an individual household tap.

Source provenance

UCMR5 Analytical Results

Fifth Unregulated Contaminant Monitoring Rule (UCMR5) — PFAS occurrence data

U.S. Environmental Protection Agency · Published 2024

Nationwide entry-point monitoring for 29 PFAS and lithium under the fifth UCMR cycle. Results are entry-point-to-distribution samples, not household-tap measurements.

How to interpret this record

This page preserves one measurement. Interpretation requires its qualifier, reporting limit, reference basis, date, sampling location, and limitations; the number alone is not a safety verdict.