Forensic evidence record · ev-utah06004-f-farmington-lithium

Lithium

A single published measurement record with its qualifier, sampling context, source identifier, method note, and stated limitations kept together.

Published evidence record

9.8 µg/LReported measurement
Back to water-system profile
9.8 µg/Lreported result
Not verified from sourcereporting limit
Sample date: 2023-09-25 to 2024-06-11sample date
2026-01-15publication date
Source observations (12)
  • lithium — Sample date: 2023-09-25

    Detected above reporting limit. = 9.8 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 2309J61-001A · Method EPA 200.7

  • lithium — Sample date: 2024-03-11

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 2403699-001A · Method EPA 200.7

  • lithium — Sample date: 2023-09-25

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 2309J61-002A · Method EPA 200.7

  • lithium — Sample date: 2024-03-11

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 2403699-002A · Method EPA 200.7

  • lithium — Sample date: 2023-11-13

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 2311998-001A · Method EPA 200.7

  • lithium — Sample date: 2024-03-11

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 2403699-003A · Method EPA 200.7

  • lithium — Sample date: 2023-09-25

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 2309J61-003A · Method EPA 200.7

  • lithium — Sample date: 2024-03-11

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 2403699-004A · Method EPA 200.7

  • lithium — Sample date: 2023-09-25

    Detected above reporting limit. = 9.3 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 2309J61-004A · Method EPA 200.7

  • lithium — Sample date: 2023-12-18

    Detected above reporting limit. = 9.6 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 2312D34-001A · Method EPA 200.7

  • lithium — Sample date: 2024-03-11

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 2403699-005A · Method EPA 200.7

  • lithium — Sample date: 2024-06-11

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 2406996-001A · Method EPA 200.7

Measurement evidence

Analyte
Lithium
Result qualifier
=
Reference basis
10.0 µg/L EPA health reference level (screening, not a legal limit)
Sampling location
Entry Point to Distribution
Water system ID
UTAH06004
Source ID
src-ucmr5-2024

Laboratory context

No laboratory method note was published with this record.

Sampling context

This result represents a entry point to distribution sample. It does not establish the condition at every distribution point or household tap.

Record limitation

System-level entry-point monitoring; not a measurement of the water at an individual household tap.

Source provenance

UCMR5 Analytical Results

Fifth Unregulated Contaminant Monitoring Rule (UCMR5) — PFAS occurrence data

U.S. Environmental Protection Agency · Published 2024

Nationwide entry-point monitoring for 29 PFAS and lithium under the fifth UCMR cycle. Results are entry-point-to-distribution samples, not household-tap measurements.

How to interpret this record

This page preserves one measurement. Interpretation requires its qualifier, reporting limit, reference basis, date, sampling location, and limitations; the number alone is not a safety verdict.

Review finding states →

Related intelligence