Change
Water utility · serves Wilmington · Delaware

Wilmington Water Department

No open EPA violations as of 2026-10-15.

EPA record checked 2026-10-06

Contact and official links

Contact Wilmington Water Department

From EPA's record for DE0000663. PurityMap is independent of Wilmington Water Department.

Mailing address
Water Work Center
WILMINGTON, DE 19801
Directions ↗
Phone and website302-576-3017

Pay your bill, start or stop service on wilmingtonde.gov.

Annual water quality reportNot in our sources yet

Every community water system publishes one each year. Your water bill or the utility's website links to it.

Where it delivers water

As listed in EPA's records. Your water bill names your supplier.

ZIP codes in Wilmington

A ZIP code is a postal area, not a water service area. Your water bill names your supplier.

Show all 26 ZIP codesShow fewer

Look up water quality by ZIP code →

Are you this utility? Correct this listing →

Test results

No result on record is above a federal legal limit

31 results are on record. These 5 come first: results above a listed reference, then those closest to a legal limit.

All 31 results and evidence →
  • Perfluorooctanoic acid (PFOA)Above EPA's 2024 limit (one sample)
    4 ng/L federal MCL
    9.9ng/L
  • Perfluorohexanoic acid (PFHxA)Within a historical reference; current applicability unverified
    400,000 ng/L Michigan EGLE state MCL · not a federal limit
    21.1ng/L
  • Perfluorobutanesulfonic acid (PFBS)Within the referenced health-based guidance value
    2,000 ng/L EPA health advisory · not a legal limit
    3.6ng/L
  • Perfluorobutanoic acid (PFBA)Detected, no limit
    No federal limit
    14.1ng/L
  • Perfluoroheptanoic acid (PFHpA)Detected, no limit
    No federal limit
    8.4ng/L
Results as a table31 results with limit, status, sample date and source
Test results for Wilmington Water Department (PWSID DE0000663), Delaware
ContaminantResultLimitStatusSampledSource
Perfluorooctanoic acid (PFOA)9.9 ng/L4.0 ng/L federal MCL (2024)Above EPA's 2024 limit (one sample)2023-02-08 to 2024-01-31UCMR5 Analytical Results: WILMINGTON WATER DEPARTMENT (DE0000663)
Perfluorobutanesulfonic acid (PFBS)3.6 ng/L2,000 ng/L EPA health advisory (screening, not a legal limit)Screening level, not a legal limitWithin the referenced health-based guidance value2023-02-08 to 2024-01-31UCMR5 Analytical Results: WILMINGTON WATER DEPARTMENT (DE0000663)
Perfluorohexanoic acid (PFHxA)21.1 ng/L400,000 ng/L Michigan EGLE state MCL (strictest US state)Within a historical reference; current applicability unverified2023-02-08 to 2024-01-31UCMR5 Analytical Results: WILMINGTON WATER DEPARTMENT (DE0000663)
Perfluorobutanoic acid (PFBA)14.1 ng/LNo federal or state limit; shown for transparencyDetected, no limit2023-02-08 to 2024-01-31UCMR5 Analytical Results: WILMINGTON WATER DEPARTMENT (DE0000663)
Perfluoroheptanoic acid (PFHpA)8.4 ng/LNo federal or state limit; shown for transparencyDetected, no limit2023-02-08 to 2024-01-31UCMR5 Analytical Results: WILMINGTON WATER DEPARTMENT (DE0000663)
Perfluoropentanoic acid (PFPeA)32.2 ng/LNo federal or state limit; shown for transparencyDetected, no limit2023-02-08 to 2024-01-31UCMR5 Analytical Results: WILMINGTON WATER DEPARTMENT (DE0000663)
11-Chloroeicosafluoro-3-oxaundecane-1-sulfonic acid (11Cl-PF3OUdS)< 5 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2023-02-08 to 2024-01-31UCMR5 Analytical Results: WILMINGTON WATER DEPARTMENT (DE0000663)
1H, 1H, 2H, 2H-perfluorodecane sulfonic acid (8:2 FTS)< 5 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2023-02-08 to 2024-01-31UCMR5 Analytical Results: WILMINGTON WATER DEPARTMENT (DE0000663)
1H, 1H, 2H, 2H-perfluorohexane sulfonic acid (4:2 FTS)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2023-02-08 to 2024-01-31UCMR5 Analytical Results: WILMINGTON WATER DEPARTMENT (DE0000663)
1H, 1H, 2H, 2H-perfluorooctane sulfonic acid (6:2 FTS)< 5 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2023-02-08 to 2024-01-31UCMR5 Analytical Results: WILMINGTON WATER DEPARTMENT (DE0000663)
4,8-Dioxa-3H-perfluorononanoic acid (ADONA)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2023-02-08 to 2024-01-31UCMR5 Analytical Results: WILMINGTON WATER DEPARTMENT (DE0000663)
9-Chlorohexadecafluoro-3-oxanone-1-sulfonic acid (9Cl-PF3ONS)< 2 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2023-02-08 to 2024-01-31UCMR5 Analytical Results: WILMINGTON WATER DEPARTMENT (DE0000663)
Hexafluoropropylene oxide dimer acid (HFPO-DA) (GenX chemicals)< 5 ng/L10 ng/L federal MCL (2024)Not detected above the reporting limit2023-02-08 to 2024-01-31UCMR5 Analytical Results: WILMINGTON WATER DEPARTMENT (DE0000663)
Lead (90th percentile)Non-Detect (ND)15 µg/L federal action levelNot detected above the reporting limit2021–2023 monitoring periodLead & Copper Rule 90th-percentile: WILMINGTON WATER DEPARTMENT (DE0000663)
Lithium< 9 µg/L10 µg/L EPA health reference level (screening, not a legal limit)Screening level, not a legal limitNot detected above the reporting limit2023-02-08 to 2023-11-07UCMR5 Analytical Results: WILMINGTON WATER DEPARTMENT (DE0000663)
N-ethyl perfluorooctanesulfonamidoacetic acid (NEtFOSAA)< 5 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2023-02-08 to 2023-11-07UCMR5 Analytical Results: WILMINGTON WATER DEPARTMENT (DE0000663)
N-methyl perfluorooctanesulfonamidoacetic acid (NMeFOSAA)< 6 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2023-02-08 to 2023-11-07UCMR5 Analytical Results: WILMINGTON WATER DEPARTMENT (DE0000663)
Nonafluoro-3,6-dioxaheptanoic acid (NFDHA)< 20 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2023-02-08 to 2024-01-31UCMR5 Analytical Results: WILMINGTON WATER DEPARTMENT (DE0000663)
Perfluoro (2-ethoxyethane) sulfonic acid (PFEESA)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2023-02-08 to 2024-01-31UCMR5 Analytical Results: WILMINGTON WATER DEPARTMENT (DE0000663)
Perfluoro-3-methoxypropanoic acid (PFMPA)< 4 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2023-02-08 to 2024-01-31UCMR5 Analytical Results: WILMINGTON WATER DEPARTMENT (DE0000663)
Perfluoro-4-methoxybutanoic acid (PFMBA)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2023-02-08 to 2024-01-31UCMR5 Analytical Results: WILMINGTON WATER DEPARTMENT (DE0000663)
Perfluorodecanoic acid (PFDA)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2023-02-08 to 2024-01-31UCMR5 Analytical Results: WILMINGTON WATER DEPARTMENT (DE0000663)
Perfluorododecanoic acid (PFDoA)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2023-02-08 to 2024-01-31UCMR5 Analytical Results: WILMINGTON WATER DEPARTMENT (DE0000663)
Perfluoroheptanesulfonic acid (PFHpS)< 3 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2023-02-08 to 2024-01-31UCMR5 Analytical Results: WILMINGTON WATER DEPARTMENT (DE0000663)
Perfluorohexanesulfonic acid (PFHxS)< 3 ng/L10 ng/L federal MCL (2024)Not detected above the reporting limit2023-02-08 to 2024-01-31UCMR5 Analytical Results: WILMINGTON WATER DEPARTMENT (DE0000663)
Perfluorononanoic acid (PFNA)< 4 ng/L10 ng/L federal MCL (2024)Not detected above the reporting limit2023-02-08 to 2024-01-31UCMR5 Analytical Results: WILMINGTON WATER DEPARTMENT (DE0000663)
Perfluorooctanesulfonic acid (PFOS)< 4 ng/L4.0 ng/L federal MCL (2024)Not detected above the reporting limit2023-02-08 to 2024-01-31UCMR5 Analytical Results: WILMINGTON WATER DEPARTMENT (DE0000663)
Perfluoropentanesulfonic acid (PFPeS)< 4 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2023-02-08 to 2024-01-31UCMR5 Analytical Results: WILMINGTON WATER DEPARTMENT (DE0000663)
Perfluorotetradecanoic acid (PFTA)< 8 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2023-02-08 to 2023-11-07UCMR5 Analytical Results: WILMINGTON WATER DEPARTMENT (DE0000663)
Perfluorotridecanoic acid (PFTrDA)< 7 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2023-02-08 to 2023-11-07UCMR5 Analytical Results: WILMINGTON WATER DEPARTMENT (DE0000663)
Perfluoroundecanoic acid (PFUnA)< 2 ng/LNo federal or state limit; shown for transparencyNot detected above the reporting limit2023-02-08 to 2024-01-31UCMR5 Analytical Results: WILMINGTON WATER DEPARTMENT (DE0000663)
EPA violations and monitoring

1health-based violation in the last 10 years · none open as of 2026-10-15

From EPA SDWIS. Counted once per contaminant per year in the Track record subject score. A violation record is a compliance fact, not a health verdict.

Sources behind this page
  • UCMR5 Analytical Results: WILMINGTON WATER DEPARTMENT (DE0000663)US EPA · published 2026-10-15
    View ↗
  • Lead & Copper Rule 90th-percentile: WILMINGTON WATER DEPARTMENT (DE0000663)US EPA SDWIS · published 2026-10-13
    View ↗
Commercial · test your own tap

The system record stops at your property line

Screening tells you if something is worth a closer look; a lab result is the number you can act on.

As an Amazon Associate, PurityMap earns from qualifying purchases. Affiliate disclosure

  • Screening: quick check, not lab-grade

    Safe Home DIY Lead in Drinking Water Combo Test Kit

    Safe Home (EnviroTestKits)

    Lead, read as one of three ranges: 0–4, 5–15 or 15+ ppb

    Turnaround: 5 minutes

    What it can't tell you: It shows a lead range, not an exact level, and tests nothing else unless you pay extra for the optional lab test.

Commercial

Filters for the PFAS found in water from Wilmington Water Department

★ Best choice: Aquasana Claryum 2-Stage Under-Sink Filter (AQ-5200), certified for PFOA and lead.

Filters for the PFAS found in water from Wilmington Water Department
PickProductCertificationPriceLink
★ Best choiceAquasana Claryum 2-Stage Under-Sink Filter (AQ-5200)AquasanaCertified for PFOA (NSF/ANSI 53, WQA)$$Check price on Amazon
Also goodAquasana Claryum 3-Stage Max Flow Under-Sink Filter (AQ-6300M)AquasanaCertified for PFOA (NSF/ANSI 53, WQA)$$Check price at Aquasana
Also goodAquasana Clean Water Machine Countertop Filter (AQ-CWM2)AquasanaCertified for PFOA (NSF/ANSI 53, WQA)$$Check price at Aquasana
See all 12 drinking-water options for PFAS
More drinking-water options for PFAS
PickProductCertificationPriceLink
Also goodSmartFlow® Reverse OsmosisAquasana · Treats only drinking water at its own faucet, not showers or the rest of the house.Certified for PFOA (NSF/ANSI 53 (includes P473), WQA)$$$Check price at Aquasana
Also goodWaterdrop G3P600 Tankless Reverse-Osmosis SystemWaterdropCertified for PFOA (NSF/ANSI 53, IAPMO)$$$Check price at Waterdrop
Also goodWaterdrop G3P800 Tankless Reverse-Osmosis SystemWaterdropCertified for PFOA (NSF/ANSI 53, IAPMO)$$$Check price at Waterdrop
Also goodAquaTru Carafe Countertop Reverse-Osmosis Purifier (AT100)AquaTruCertified for PFOA (NSF/ANSI 53, IAPMO)$$$Check price on Amazon
Also goodAquaTru Classic Countertop Reverse-Osmosis Purifier (AT2000)AquaTruCertified for PFOA (NSF/ANSI 53, IAPMO)$$$Check price on Amazon
Also goodPatriot Pure Ultimate Water Filtration SystemPatriot Pure (4Patriots)Certified for PFOA (NSF/ANSI 53, NSF, IAPMO)$$Check price on Amazon
Also goodiSpring RCC7AK Alkaline Reverse Osmosis SystemiSpring · It treats only the water from its own faucet and sends part of the water to the drain; the NSF listing for the plain RCC7AK covers dissolved solids, not lead or PFAS.Use code REFISPRING at checkout: 10% off your first iSpring order.Brand lab-tested for PFAS, not independently certified for PFOA, Perfluorobutanesulfonic acid (PFBS), Perfluorohexanoic acid (PFHxA), Perfluorobutanoic acid (PFBA), Perfluoroheptanoic acid (PFHpA) and Perfluoropentanoic acid (PFPeA)$$Check price at iSpring
Also goodiSpring RO5004F Tankless Reverse Osmosis System with UViSpring · Its PFAS and lead reduction claims are iSpring's own, with no third-party certification named for this model, and it treats only the water at its own faucet.Use code REFISPRING at checkout: 10% off your first iSpring order.Brand lab-tested for PFAS, not independently certified for PFOA, Perfluorobutanesulfonic acid (PFBS), Perfluorohexanoic acid (PFHxA), Perfluorobutanoic acid (PFBA), Perfluoroheptanoic acid (PFHpA) and Perfluoropentanoic acid (PFPeA)$$$Check price at iSpring
Also goodWaterdrop X12 Reverse Osmosis SystemWaterdrop · Its IAPMO NSF/ANSI 58 certification covers TDS reduction only, so its PFAS and lead claims rest on Waterdrop's own SGS lab testing.Brand lab-tested for PFAS, not independently certified for PFOA, Perfluorobutanesulfonic acid (PFBS), Perfluorohexanoic acid (PFHxA), Perfluorobutanoic acid (PFBA), Perfluoroheptanoic acid (PFHpA) and Perfluoropentanoic acid (PFPeA)$$$$Check price at Waterdrop

★ Best choice: HealthShield™, certified for PFOA and Perfluoroheptanoic acid (PFHpA).

Filters for the PFAS found in water from Wilmington Water Department
PickProductCertificationPriceLink
★ Best choiceHealthShield™Aquasana · Does not soften water or remove hardness minerals, and it needs a 120V outlet for its performance indicator.Certified for PFOA and Perfluoroheptanoic acid (PFHpA) (NSF/ANSI 53, WQA)$$$$Check price at Aquasana
$ Budget pickiSpring WGB32B-PFKS PFAS & Heavy Metals Whole House FilteriSpring · It does not reduce total dissolved solids or soften hard water, and its PFAS result comes from SGS lab testing rather than an NSF/ANSI certification.Use code REFISPRING at checkout: 10% off your first iSpring order.Brand lab-tested for PFAS, not independently certified for PFOA, Perfluorobutanesulfonic acid (PFBS), Perfluorohexanoic acid (PFHxA), Perfluorobutanoic acid (PFBA), Perfluoroheptanoic acid (PFHpA) and Perfluoropentanoic acid (PFPeA)$$$Check price at iSpring

Also: lead picks →

PurityMap earns a commission from these links. "Best choice" and "Budget pick" go to certified products first; commission never decides them. As an Amazon Associate, PurityMap earns from qualifying purchases. Affiliate disclosure.

Lead service lines

Ask your utility first

Wilmington Water Department reported 1,708 lead and 669 galvanized service lines to replace in EPA’s inventory (2026Q2). Many utilities replace these lines for free or share the cost. Ask Wilmington Water Department whether your home’s line is on its list before you pay anyone.

Local help

Think your plumbing may be adding lead?

Call to be connected with a local plumbing provider about lead service lines, repiping or fixture replacement.

Questions

About Wilmington Water Department

Follow Wilmington Water Department

One email when a new sampling round is published or a result moves across its reference.

Follow this water →
How do I contact Wilmington Water Department?

Its official website is wilmingtonde.gov, its phone number on EPA record is 302-576-3017 and its mailing address is Water Work Center, WILMINGTON, DE 19801. These details come from the system's EPA record and a check of its website.

How do I pay my Wilmington Water Department bill?

Bills, starting service and stopping service are handled by Wilmington Water Department on its official website, wilmingtonde.gov. PurityMap does not take payments.

Which cities does Wilmington Water Department serve?

EPA's records list Wilmington Water Department as serving Wilmington, Delaware. Your water bill names your supplier.

Has Wilmington Water Department tested for PFAS?

PurityMap's record for Wilmington Water Department holds results for 29 PFAS substances. 6 were detected, and none is above a federal legal limit. Each result links to its source in the city report.

Does Wilmington Water Department have any EPA violations?

No open EPA violations as of 2026-10-15: that is what EPA's record shows for Wilmington Water Department. The record comes from EPA's SDWIS compliance database.

Where does Wilmington Water Department get its water?

Wilmington Water Department is on EPA record as drawing from surface water.

Something off with your water's smell, color or taste?

Start with the hot-or-cold tap check. Where Wilmington Water Department reported something related, it's shown below.