Skip to content
PurityMap
Water QualityContaminantsSolutionsLearn & Trust
Search city, ZIP, contaminant⌘KFind my waterMenu
PurityMap

Public water records, made legible. Every number traceable to its source.

  1. Location→
  2. Water system→
  3. Evidence→
  4. Treatment→
  5. Product
Record updates

Follow your water

One email when a new sampling round is published or a result moves across its reference.

Double opt-in: we email a confirmation link. Unsubscribe anytime. No spam.

Find my waterAddress, city, ZIP or PWSID→

ExploreWater Quality

  • Find My Water→
  • National Map→
  • By State→
  • By City→
  • By ZIP Code→
  • Water Systems→
  • Rankings→
  • Compare Places→

UnderstandContaminants

  • All Contaminants→
  • PFAS→
  • Lead→
  • Nitrate→
  • Water Hardness→

SolveSolutions

  • Find a Solution→
  • Water Filters→
  • Compare Products→
  • Treatment Technologies→
  • Compare Treatments→
  • Water Tools→

TrustLearn & Trust

  • Journal→
  • How We Analyze Water→
  • Data Sources→
  • Trust Center→
  • Search→

CompanyPurityMap

  • About PurityMap→
  • Contact→
  • Follow Your Water→
  • Submit a Correction→
  • Claim a Utility→
© 2026 PurityMap
PrivacyTermsHealth disclaimerAffiliate disclosureSitemap
  1. PurityMap
  2. Water Quality
  3. Illinois
  4. NORTH CHICAGOIL0971250
Change
Updated 2026-09-16
Water system record · IL0971250

North Chicago

North Chicago serves 16,813 people from surface water. 32 results are on record. No measured result is above a legal limit; a past health-based violation (Di(2-ethylhexyl) phthalate) is on record.

Explore the findingsIs this my supplier?Follow
Purity ScoreHow the 96 is builtIL0971250 · 16,813 served
96/100 · ExcellentConfidence: moderate
above a reference
1
detected, within reference or no limit
0
not detected
31
  • PFAS (forever chemicals)100
  • Metals & lead100
  • Disinfection by-products—Not monitored
  • Track record (violations)72

Subject scores out of 100. 3 of 4 subjects measured; disinfection pending a source.

Not in this score: Di(2-ethylhexyl) phthalate. Listed in the findings, not graded by the Purity Score.

System-level record, not a test of your tap. How we score

Source
Surface Water
Serves 1 city area on record.
Population
16,813
as reported to EPA
Type
Community Water System
Illinois
Cities
1
North Chicago
Records
32 results
latest 2026
FindingsAll resultsComplianceWhat you can doRecordsFAQ
What stands out

No measured result is above a legal limit

No measured result is above a legal limit; a past health-based violation (Di(2-ethylhexyl) phthalate) is on record.

Coverage by group

32 results on record
  • PFAS (forever chemicals)
    29 not detected
  • Metals & lead
    1 not detected
  • Disinfection by-products
    Not monitored
  • Other
    1 above · 1 not detected
  • Above a limit or reference
  • Detected
  • Not detected
  • Not monitored
Every detected result

One detected result

  • Di(2-e
    Di(2-ethylhexyl) phthalateEPA SDWIS violations · 2024
    0.006 mg/L
    8UG/L
    Above limit
31 other contaminants tested, none detected
  • 11Cl-PF3OUdS
  • 4:2 FTS
  • 6:2 FTS
  • 8:2 FTS
  • 9Cl-PF3ONS
  • ADONA
  • HFPO-DA (GenX)
  • NEtFOSAA
  • NFDHA
  • NMeFOSAA
  • PFBA
  • PFBS
  • PFDA
  • PFDoA
  • PFEESA
  • PFHpA
  • PFHpS
  • PFHxA
  • PFHxS
  • PFMBA
  • PFMPA
  • PFNA
  • PFOA
  • PFOS
  • PFPeA
  • PFPeS
  • PFTA
  • PFTrDA
  • PFUnA
  • Lithium
  • Lead (90th percentile)

Compliance and coverage

Lead service lines

5,653service lines inventoried

  • Lead849
  • Galvanized, to replace0
  • Material unknown4,804
  • Not lead0

From the utility's inventory reported to EPA (2026Q2). Look up your address with the utility.

Compliance

2health-based violations in the last 10 years

From EPA SDWIS. Counted once per contaminant per year, as in the Track record score.

Not in this recordDisinfection by-products weren't monitored in this dataset

No result is not a pass. Your utility's annual water quality report may list them, and a certified lab test covers your own tap.

A federal limit (an MCL or action level) is an enforceable legal cap; a health goal is often stricter. Meeting the limit is a compliance fact, not a health clearance, and PurityMap publishes no overall compliance verdict.

What you can do

Start with a test of your own tap

  1. 01 · TestTest your own tap

    The records describe the system. A certified lab test shows what reaches your glass.

    Certified lab
    How to test your tap →

Test your own tap

Screening tells you if something is worth a closer look; a lab result is the number you can act on.

As an Amazon Associate, PurityMap earns from qualifying purchases. Affiliate disclosure.

  • Screening: quick check, not lab-grade

    Watersafe Drinking Water Test Kit

    Silver Lake Research

    Lead, bacteria, nitrate, copper, iron, chlorine, hardness and pH

    • Turnaround: Minutes; the bacteria test can take up to 48 hours

    What it can't tell you: Each test gives a yes/no or a rough range, not a lab number, and it cannot detect PFAS or arsenic.

    Check price on Amazon
  • Lab-certified results

    ETR Labs Basic Water Quality Test Kit

    ETR Laboratories

    50+ substances, including lead, copper, arsenic, nitrate, hardness and coliform bacteria

    • Analyzed by Environmental Testing and Research Laboratories (ETR Labs), Leominster, MA · ISO/IEC 17025:2017, ANAB certificate AT-2638
    • Turnaround: 2–4 business days after the lab receives it

    What it can't tell you: It does not test PFAS, and not every result on the panel falls under the lab's accredited scope.

    Check price on Amazon

When your results arrive, read them here →

Questions

Frequently asked questions

Who does NORTH CHICAGO serve?

NORTH CHICAGO (PWS ID IL0971250) is a public water system serving 16,813 people in North Chicago, Illinois.

Where does NORTH CHICAGO get its water?

NORTH CHICAGO is on record as drawing from surface water. The source shapes which contaminants matter most for this system.

What does NORTH CHICAGO's monitoring record show?

PurityMap's record for NORTH CHICAGO holds 32 findings: 1 above a reference and 31 not detected, from 32 evidence records. Every finding links to its source; a substance that was never monitored is shown as pending, not as a pass.

Is NORTH CHICAGO's water safe to drink?

PurityMap does not issue a safety verdict. It publishes NORTH CHICAGO's measured results against each contaminant's benchmark so you can read them in context. Safety depends on the specific finding, your plumbing, and how the water reaches your tap.

How current is this NORTH CHICAGO data?

The latest published record for NORTH CHICAGO is dated 2026-09-16. Utilities report on regulatory cycles, so results reflect the monitoring period rather than a live reading.

Does this assessment represent my home's tap water?

No. It is assessed at the water-system level from NORTH CHICAGO's own monitoring. It does not cover the service line to your building or the plumbing inside it, which can add lead and other metals after the water leaves the system. A tap test is the way to know what reaches your glass.

What contaminants were detected in NORTH CHICAGO?

Di(2-ethylhexyl) phthalate was detected in this record. Each finding shows its measured value, its reference and its source on this page.

Follow this water

Follow North Chicago

One email when a new sampling round is published, a result moves above or below its reference, or the system's score changes.

Double opt-in: we email a confirmation link. Unsubscribe anytime. No spam.

Cities served by this system
  • North Chicago

As listed for this system in EPA's records. Your water bill names your supplier.

Sources and dataAll 32 records and their sourcesEPA UCMR 5 · EPA SDWIS (Lead & Copper Rule) · EPA SDWIS violations+
SubstanceResultReferenceSampledStatusEvidence
11-Chloroeicosafluoro-3-oxaundecane-1-sulfonic acid (11Cl-PF3OUdS)< 5 ng/LNo federal or state limit; shown for transparency2025-02-25 to 2025-11-11Not detected—
1H, 1H, 2H, 2H-perfluorohexane sulfonic acid (4:2 FTS)< 3 ng/LNo federal or state limit; shown for transparency2025-02-25 to 2025-11-11Not detected—
1H, 1H, 2H, 2H-perfluorooctane sulfonic acid (6:2 FTS)< 5 ng/LNo federal or state limit; shown for transparency2025-02-25 to 2025-11-11Not detected—
1H, 1H, 2H, 2H-perfluorodecane sulfonic acid (8:2 FTS)< 5 ng/LNo federal or state limit; shown for transparency2025-02-25 to 2025-11-11Not detected—
9-Chlorohexadecafluoro-3-oxanone-1-sulfonic acid (9Cl-PF3ONS)< 2 ng/LNo federal or state limit; shown for transparency2025-02-25 to 2025-11-11Not detected—
4,8-Dioxa-3H-perfluorononanoic acid (ADONA)< 3 ng/LNo federal or state limit; shown for transparency2025-02-25 to 2025-11-11Not detected—
Hexafluoropropylene oxide dimer acid (HFPO-DA) (GenX chemicals)< 5 ng/L10 ng/L federal MCL (2024)2025-02-25 to 2025-11-11Not detected—
N-ethyl perfluorooctanesulfonamidoacetic acid (NEtFOSAA)< 5 ng/LNo federal or state limit; shown for transparency2025-02-25 to 2025-11-11Not detected—
Nonafluoro-3,6-dioxaheptanoic acid (NFDHA)< 20 ng/LNo federal or state limit; shown for transparency2025-02-25 to 2025-11-11Not detected—
N-methyl perfluorooctanesulfonamidoacetic acid (NMeFOSAA)< 6 ng/LNo federal or state limit; shown for transparency2025-02-25 to 2025-11-11Not detected—
Perfluorobutanoic acid (PFBA)< 5 ng/LNo federal or state limit; shown for transparency2025-02-25 to 2025-11-11Not detected—
Perfluorobutanesulfonic acid (PFBS)< 3 ng/L2,000 ng/L EPA health advisory (screening, not a legal limit)2025-02-25 to 2025-11-11Not detected—
Perfluorodecanoic acid (PFDA)< 3 ng/LNo federal or state limit; shown for transparency2025-02-25 to 2025-11-11Not detected—
Perfluorododecanoic acid (PFDoA)< 3 ng/LNo federal or state limit; shown for transparency2025-02-25 to 2025-11-11Not detected—
Perfluoro (2-ethoxyethane) sulfonic acid (PFEESA)< 3 ng/LNo federal or state limit; shown for transparency2025-02-25 to 2025-11-11Not detected—
Perfluoroheptanoic acid (PFHpA)< 3 ng/LNo federal or state limit; shown for transparency2025-02-25 to 2025-11-11Not detected—
Perfluoroheptanesulfonic acid (PFHpS)< 3 ng/LNo federal or state limit; shown for transparency2025-02-25 to 2025-11-11Not detected—
Perfluorohexanoic acid (PFHxA)< 3 ng/L400,000 ng/L Michigan EGLE state MCL (strictest US state)2025-02-25 to 2025-11-11Not detected—
Perfluorohexanesulfonic acid (PFHxS)< 3 ng/L10 ng/L federal MCL (2024)2025-02-25 to 2025-11-11Not detectedView evidence
Perfluoro-4-methoxybutanoic acid (PFMBA)< 3 ng/LNo federal or state limit; shown for transparency2025-02-25 to 2025-11-11Not detected—
Perfluoro-3-methoxypropanoic acid (PFMPA)< 4 ng/LNo federal or state limit; shown for transparency2025-02-25 to 2025-11-11Not detected—
Perfluorononanoic acid (PFNA)< 4 ng/L10 ng/L federal MCL (2024)2025-02-25 to 2025-11-11Not detected—
Perfluorooctanoic acid (PFOA)< 4 ng/L4.0 ng/L federal MCL (2024)2025-02-25 to 2025-11-11Not detectedView evidence
Perfluorooctanesulfonic acid (PFOS)< 4 ng/L4.0 ng/L federal MCL (2024)2025-02-25 to 2025-11-11Not detectedView evidence
Perfluoropentanoic acid (PFPeA)< 3 ng/LNo federal or state limit; shown for transparency2025-02-25 to 2025-11-11Not detected—
Perfluoropentanesulfonic acid (PFPeS)< 4 ng/LNo federal or state limit; shown for transparency2025-02-25 to 2025-11-11Not detected—
Perfluorotetradecanoic acid (PFTA)< 8 ng/LNo federal or state limit; shown for transparency2025-02-25 to 2025-11-11Not detected—
Perfluorotridecanoic acid (PFTrDA)< 7 ng/LNo federal or state limit; shown for transparency2025-02-25 to 2025-11-11Not detected—
Perfluoroundecanoic acid (PFUnA)< 2 ng/LNo federal or state limit; shown for transparency2025-02-25 to 2025-11-11Not detected—
Lithium< 9 µg/L10 µg/L EPA health reference level (screening, not a legal limit)2025-02-25 to 2025-11-11Not detected—
Lead (90th percentile)Non-Detect (ND)15 µg/L federal action level2026–2026 monitoring period (still open)Not detectedView evidence
Di(2-ethylhexyl) phthalate8 UG/L0.006 mg/L2024Above guidelineView evidence
  • UCMR5 Analytical Results

    UCMR5 Analytical Results: NORTH CHICAGO (IL0971250)

    US EPA

    Published
    2026-01-15
    Newest sample
    2025-11-11
    Findings here
    30

    View source ↗Source record

  • State SDWIS Compliance Record

    Lead & Copper Rule 90th-percentile: NORTH CHICAGO (IL0971250)

    US EPA SDWIS

    Published
    2026-07-09
    Newest sample
    2026
    Findings here
    1

    View source ↗Source record

  • State SDWIS Compliance Record

    EPA SDWIS Violations & Enforcement: NORTH CHICAGO (IL0971250)

    US EPA SDWIS

    Published
    2026-07-09
    Newest sample
    2024
    Findings here
    1

    View source ↗Source record

North Chicago water reportAll water systemsCompare with another systemFilter guide (general)Water quality mapHow we analyze waterReport a correctionClaim this utility profile