City water report · 2026

Is Aurora, IL Tap Water Safe to Drink?

Short answer: In the 2024–2026 records we hold for Aurora, lead (90th percentile) is above its federal limit. Also worth knowing: lithium sits above a screening level, and the water is hard. 7 substances were detected and 25 were tested and not detected. The water is from City of Aurora, serving 183,000 residents.

  • Year 2026
  • Utility City of Aurora
  • Coverage 32 records
  • Updated 2026-10-15
Water utility

Where Aurora’s water comes from

Utility
City of Aurora
Water system
AURORA · IL0894070
Source water
Surface water
Disinfectant
not on record
Population served
183,000
Reporting period
Sampled 2024–2026
Monitoring coverage
32 records · 3 of 4 groups measured
Service lines
16,799 lead, 138 galvanized, 93 unknown material (EPA inventory, 2026Q2)
Listed match

EPA lists this system for the city. Your water bill or annual water quality report names your actual supplier. Source: EPA SDWIS 2026Q2.

  • AURORAThis report
    IL0894070 · 183,000 served
Why this matters
  1. 1
    Source

    Surface water

  2. 2
    Treatment

    The treatment details are not on record.

  3. 3
    Distribution

    Mains, then your building’s service line.

  4. 4
    Your tap

    Plumbing inside the building is outside this record.

At a glance

Aurora water in four numbers

Purity ScoreAURORA · PWSID IL0894070
7Detected3 above a reference
3Above a referenceof 32 records
0Health-based violationslast 10 years · EPA SDWIS

Lead (90th percentile) is above its federal limit; lithium sits above a screening level, and the water is hard.

What we found

7 detected results, by distance from their limit

LithiumAbove screening · Screening level10 µg/L EPA health reference level (screening, not a legal limit)18.6µg/L
① · Measured

18.6 µg/L, sampled 2024-05-22 to 2025-02-11. EPA UCMR 5.

② · Compared

10 µg/L EPA health reference level (screening, not a legal limit).

③ · Meaning

Detected at up to 18.6 µg/L (above the 10 µg/L EPA health reference level; a screening level, not a legal limit).

④ · Where it matters

Where it enters is not in this record.

⑤ · What to do

Test your own tap first. To reduce it: Depends on the contaminant (The certifier's listing for each named contaminant).

See the evidence record →
Lead (90th percentile)Above limit · Action level15 µg/L federal action level25.7µg/L
① · Measured

25.7 µg/L, sampled 2026–2026 monitoring period (still open). EPA SDWIS (Lead & Copper Rule).

② · Compared

15 µg/L federal action level. EPA health goal (MCLG): 0.

③ · Meaning

The 90th-percentile tap result was 25.7 µg/L (above the 15 µg/L action level).

④ · Where it matters

Usually from lead service lines, solder and fixtures inside buildings, after the water leaves treatment.

⑤ · What to do

Test your own tap first. To reduce it: Lead-certified carbon filter, or reverse osmosis (NSF/ANSI 53 (lead)).

See the evidence record →
Perfluorobutanesulfonic acid (PFBS)Within reference · Screening level2,000 ng/L EPA health advisory (screening, not a legal limit)3.7ng/L
① · Measured

3.7 ng/L, sampled 2024-05-22 to 2025-02-11. EPA UCMR 5.

② · Compared

2,000 ng/L EPA health advisory (screening, not a legal limit).

③ · Meaning

Detected at up to 3.7 ng/L (below the 2,000 ng/L EPA health advisory; a screening level, not a legal limit).

④ · Where it matters

Comes with the source water; home plumbing does not add it.

⑤ · What to do

Test your own tap first. To reduce it: Reverse osmosis, or carbon certified for PFAS (NSF/ANSI 53 or 58, with PFBS named on the listing).

See the evidence record →
Perfluorohexanoic acid (PFHxA)Within reference · State limit400,000 ng/L Michigan EGLE state MCL (strictest US state)4.7ng/L
① · Measured

4.7 ng/L, sampled 2024-05-22 to 2025-02-11. EPA UCMR 5.

② · Compared

400,000 ng/L Michigan EGLE state MCL (strictest US state): a state limit.

③ · Meaning

Detected at up to 4.7 ng/L (below the 400,000 ng/L historical comparison reference).

④ · Where it matters

Comes with the source water; home plumbing does not add it.

⑤ · What to do

Test your own tap first. To reduce it: Reverse osmosis, or carbon certified for PFAS (NSF/ANSI 53 or 58, with PFHxA named on the listing).

See the evidence record →
Water hardnessAbove aesthetic · Aesthetic, no health limitAesthetic, no federal health limit7.9gpg
① · Measured

7.9 gpg, sampled 2025. Utility CCR.

② · Compared

Aesthetic, no federal health limit.

③ · Meaning

110–160 mg/L as CaCO3 (6.4–9.4 grains/gal) across the system; hard at the midpoint (135 mg/L). Aesthetic (scale/appliances), not a health finding.

④ · Where it matters

Shows up as scale in kettles, water heaters and fixtures.

⑤ · What to do

Test your own tap first. To reduce it: Ion-exchange water softener (NSF/ANSI 44 (softeners)).

See the evidence record →
Perfluorobutanoic acid (PFBA)Detected · no limit · No federal limitNo federal or state limit; shown for transparency5.9ng/L
① · Measured

5.9 ng/L, sampled 2024-05-22 to 2025-02-11. EPA UCMR 5.

② · Compared

No federal limit is on record for it.

③ · Meaning

Detected at up to 5.9 ng/L. No federal or state limit exists for this substance; shown for transparency, not graded.

④ · Where it matters

Comes with the source water; home plumbing does not add it.

⑤ · What to do

Test your own tap first. To reduce it: Reverse osmosis, or carbon certified for PFAS (NSF/ANSI 53 or 58, with PFBA named on the listing).

See the evidence record →
Perfluoropentanoic acid (PFPeA)Detected · no limit · No federal limitNo federal or state limit; shown for transparency5.3ng/L
① · Measured

5.3 ng/L, sampled 2024-05-22 to 2025-02-11. EPA UCMR 5.

② · Compared

No federal limit is on record for it.

③ · Meaning

Detected at up to 5.3 ng/L. No federal or state limit exists for this substance; shown for transparency, not graded.

④ · Where it matters

Comes with the source water; home plumbing does not add it.

⑤ · What to do

Test your own tap first. To reduce it: Reverse osmosis, or carbon certified for PFAS (NSF/ANSI 53 or 58, with PFPeA named on the listing).

See the evidence record →
25 others tested, none detectedshow
  • 11Cl-PF3OUdS
  • 8:2 FTS
  • 4:2 FTS
  • 6:2 FTS
  • ADONA
  • 9Cl-PF3ONS
  • HFPO-DA (GenX)
  • NEtFOSAA
  • NMeFOSAA
  • NFDHA
  • PFEESA
  • PFMPA
  • PFMBA
  • PFDA
  • PFDoA
  • PFHpS
  • PFHpA
  • PFHxS
  • PFNA
  • PFOS
  • PFOA
  • PFPeS
  • PFTA
  • PFTrDA
  • PFUnA

AURORA (EPA PWSID IL0894070) delivers surface water to 183,000 residents. This report reflects 29 individual PFAS result(s) from the source UCMR5 observations and the latest Lead & Copper Rule 90th-percentile result. The utility's 2025 CCR reports hard water.

Track record

0health-based violations in the last 10 years

From EPA SDWIS. A clean violation history means no enforcement action was recorded; it does not cover contaminants without a limit.

Not in this recordDisinfection by-products weren't monitored in this dataset

No result is not a pass. Your utility's annual water quality report may list them, and a certified lab test covers your own tap.

Your household

Your tap can differ from the city record

The record describes water leaving treatment and samples across the system. Pipes, solder and fixtures inside a building can add lead the record can’t see, especially in older buildings with lead service lines.

Test your water
  1. City
    Treated water

    Measured in this report

  2. Mains
    Distribution network

    Sampled across the system

  3. Building
    Service line and plumbing

    Not in this record

  4. Tap
    Your glass

    Only a tap test measures it

Test first, then treat

Water testing in Aurora, IL

  1. 01Test

    Know what comes from your tap, starting with a first-draw lead sample.

  2. 02Match

    Compare each result with its named reference in our test reader.

  3. 03Treat

    Choose a technology certified for what your test found.

Commercial

Test kits

Affiliate links

Screening tells you if something is worth a closer look; a lab result is the number you can act on.

As an Amazon Associate, PurityMap earns from qualifying purchases. Affiliate disclosure.

  • Lab-certified results

    ETR Labs Basic Water Quality Test Kit

    ETR Laboratories

    50+ substances, including lead, copper, arsenic, nitrate, hardness and coliform bacteria

    What it can't tell you: It does not test PFAS, and not every result on the panel falls under the lab's accredited scope.

  • Screening: quick check, not lab-grade

    Varify 17-in-1 Complete Water Test Kit

    Varify

    17 strip readings, including lead, chlorine, fluoride, iron and hardness, plus 2 coliform bacteria tests

    • Turnaround: About 1 minute; the bacteria test takes 48 hours

    What it can't tell you: Strip colors give rough ranges, not lab numbers, and it cannot detect PFAS or arsenic.

When your results arrive, read them here → · Compare every kit we list

Illinois Environmental Protection Agency certifies the labs that test drinking water in Illinois. Find a certified lab in Illinois ↗ · What lab tests cost →

Treatment matching

What can reduce what was found here

FindingReference typeTechnologyCertification to check
Lithium18.6 µg/LScreening levelDepends on the contaminantThe certifier's listing for each named contaminant
Lead (90th percentile)25.7 µg/LAction levelLead-certified carbon filter, or reverse osmosisNSF/ANSI 53 (lead)
Perfluorobutanesulfonic acid (PFBS)3.7 ng/LScreening levelReverse osmosis, or carbon certified for PFASNSF/ANSI 53 or 58, with PFBS named on the listing
Perfluorohexanoic acid (PFHxA)4.7 ng/LState limitReverse osmosis, or carbon certified for PFASNSF/ANSI 53 or 58, with PFHxA named on the listing
Water hardness7.9 gpgAesthetic, no health limitIon-exchange water softenerNSF/ANSI 44 (softeners)
Perfluorobutanoic acid (PFBA)5.9 ng/LNo federal limitReverse osmosis, or carbon certified for PFASNSF/ANSI 53 or 58, with PFBA named on the listing
Perfluoropentanoic acid (PFPeA)5.3 ng/LNo federal limitReverse osmosis, or carbon certified for PFASNSF/ANSI 53 or 58, with PFPeA named on the listing

Understand water treatment technologies →

Commercial

Filters for the lead found in Aurora water

Affiliate links

★ Best choice: Brita Elite Water Filter Pitcher, certified for lead.

Filters for the lead found in Aurora water
PickProductDetails and priceCertificationWhy it’s listedLink
★ Best choicePitcherBrita Elite Water Filter PitcherBritaTreatsleadPrice$Certified for Lead (NSF/ANSI 53, WQA)Why it’s listed: its current certification names lead, found in Aurora’s record.See the evidenceCheck price on Amazon
Also goodUnder-sinkAquasana Claryum 3-Stage Max Flow Under-Sink Filter (AQ-6300M)AquasanaTreatsleadPrice$$Certified for Lead (NSF/ANSI 53, WQA)Why it’s listed: its current certification names lead, found in Aurora’s record.See the evidenceCheck price at Aquasana
Also goodCountertopAquasana Clean Water Machine Countertop Filter (AQ-CWM2)AquasanaTreatsleadPrice$$Certified for Lead (NSF/ANSI 53, WQA)Why it’s listed: its current certification names lead, found in Aurora’s record.See the evidenceCheck price at Aquasana
See all 16 drinking-water options for lead
More drinking-water options for lead
PickProductDetails and priceCertificationWhy it’s listedLink
Also goodReverse osmosisSmartFlow® Reverse OsmosisAquasana · Treats only drinking water at its own faucet, not showers or the rest of the house.TreatsleadTechnologyReverse osmosisPrice$$$Certified for lead (WQA)Why it’s listed: its current certification names lead, found in Aurora’s record.See the evidenceCheck price at Aquasana
Also goodUnder-sinkWaterdrop G3P600 Tankless Reverse-Osmosis SystemWaterdropTreatsleadPrice$$$Certified for Lead (NSF/ANSI 58-2024, IAPMO)Why it’s listed: its current certification names lead, found in Aurora’s record.See the evidenceCheck price at Waterdrop
Also goodUnder-sinkWaterdrop G3P800 Tankless Reverse-Osmosis SystemWaterdropTreatsleadPrice$$$Certified for Lead (NSF/ANSI 58-2024, IAPMO)Why it’s listed: its current certification names lead, found in Aurora’s record.See the evidenceCheck price at Waterdrop
Also goodCountertopAquaTru Carafe Countertop Reverse-Osmosis Purifier (AT100)AquaTruTreatsleadPrice$$$Certified for Lead (NSF/ANSI 58, IAPMO)Why it’s listed: its current certification names lead, found in Aurora’s record.See the evidenceCheck price on Amazon
Also goodCountertopAquaTru Classic Countertop Reverse-Osmosis Purifier (AT2000)AquaTruTreatsleadPrice$$$Certified for Lead (NSF/ANSI 58, IAPMO)Why it’s listed: its current certification names lead, found in Aurora’s record.See the evidenceCheck price on Amazon
Also goodUnder-sinkAquasana Claryum 2-Stage Under-Sink Filter (AQ-5200)AquasanaTreatsleadPrice$$Certified for Lead (NSF/ANSI 53, WQA)Why it’s listed: its current certification names lead, found in Aurora’s record.See the evidenceCheck price on Amazon
Also goodPitcherCulligan ZeroWater 10-Cup Pitcher (ZEROP10)Culligan ZeroWaterTreatsleadPrice$Certified for Lead (NSF/ANSI 53, IAPMO)Why it’s listed: its current certification names lead, found in Aurora’s record.See the evidenceCheck price on Amazon
Also goodUnder-sinkFrizzlife SP99 Under-Sink FilterFrizzlife Technology IncTreatsleadPrice$$Certified for Lead (NSF/ANSI 53-2024, IAPMO)Why it’s listed: its current certification names lead, found in Aurora’s record.See the evidenceCheck price on Amazon
Also goodFaucet-mountPUR Plus Faucet Filter (FM2500V)PURTreatsleadPrice$Certified for Lead (NSF/ANSI 53, IAPMO)Why it’s listed: its current certification names lead, found in Aurora’s record.See the evidenceCheck price on Amazon
Also goodCountertopPatriot Pure Ultimate Water Filtration SystemPatriot Pure (4Patriots)TreatsleadPrice$$Certified for Lead (NSF/ANSI 53, NSF, IAPMO)Why it’s listed: its current certification names lead, found in Aurora’s record.See the evidenceCheck price on Amazon
Also goodReverse osmosisiSpring RCC7AK Alkaline Reverse Osmosis SystemiSpring · It treats only the water from its own faucet and sends part of the water to the drain; the NSF listing for the plain RCC7AK covers dissolved solids, not lead or PFAS.Use code REFISPRING at checkout: 10% off your first iSpring order.TechnologyReverse osmosisPrice$$Brand lab-tested, not independently certified for leadSee the evidenceCheck price at iSpring
Also goodReverse osmosisiSpring RO5004F Tankless Reverse Osmosis System with UViSpring · Its PFAS and lead reduction claims are iSpring's own, with no third-party certification named for this model, and it treats only the water at its own faucet.Use code REFISPRING at checkout: 10% off your first iSpring order.TechnologyReverse osmosisPrice$$$Brand lab-tested, not independently certified for leadSee the evidenceCheck price at iSpring
Also goodReverse osmosisWaterdrop X12 Reverse Osmosis SystemWaterdrop · Its IAPMO NSF/ANSI 58 certification covers TDS reduction only, so its PFAS and lead claims rest on Waterdrop's own SGS lab testing.TechnologyReverse osmosisPrice$$$$Brand lab-tested, not independently certified for leadSee the evidenceCheck price at Waterdrop

★ Best available: iSpring WGB32B-PFKS PFAS & Heavy Metals Whole House Filter, the best fit here; nothing in this group is certified yet.

Filters for the lead found in Aurora water
PickProductDetails and priceCertificationWhy it’s listedLink
★ Best availableWhole-houseiSpring WGB32B-PFKS PFAS & Heavy Metals Whole House FilteriSpring · It does not reduce total dissolved solids or soften hard water, and its PFAS result comes from SGS lab testing rather than an NSF/ANSI certification.Use code REFISPRING at checkout: 10% off your first iSpring order.Price$$$Brand lab-tested, not independently certified for leadSee the evidenceCheck price at iSpring

Also: PFAS picks → · hard water picks →

Certified filters for lithium →

PurityMap earns a commission from these links. "Best choice" and "Budget pick" go to certified products first; commission never decides them. As an Amazon Associate, PurityMap earns from qualifying purchases. Affiliate disclosure.

Lead service lines

Ask your utility first

City of Aurora reported 16,799 lead and 138 galvanized service lines to replace in EPA’s inventory (2026Q2). Many utilities replace these lines for free or share the cost. Ask City of Aurora whether your home’s line is on its list before you pay anyone.

Local help

Think your plumbing may be adding lead?

Call to be connected with a local plumbing provider about lead service lines, repiping or fixture replacement.

Is this right for my home?

Choose your situation

Your situation
Your path: I live in an older buildingLead from plumbing is the main question

Older buildings may have lead service lines, solder or fixtures. Aurora’s record shows lead at 25.7 µg/L (15 µg/L federal action level). Test first-draw water, then filter if needed.

Look forLead reduction: NSF/ANSI 53 (lead)
How to test your tap →
Your path: I care about PFASCheck what was tested

4 of 29 PFAS tested were detected in Aurora’s record (PFBS 3.7 ng/L, PFHxA 4.7 ng/L and PFBA 5.9 ng/L, and more). If PFAS matters to you, a filter certification names each compound it covers.

Look forNSF/ANSI 53 or 58, with each compound you care about named on the listing
PFAS in Aurora →
Your path: My water tastes of chlorineThe disinfectant is not in this record

Most utilities keep chlorine or chloramine in the pipes. A carbon filter certified for taste and odor reduces either; your utility can tell you which it uses.

Look forNSF/ANSI 42 (chlorine taste and odor)
Water treatment technologies →
Your path: I have scale or hard waterAurora water is hard (7.9 gpg)

Scale is a comfort and appliance issue, not a health one.

Look forSoftener: NSF/ANSI 44 (softeners)
Hard water in Aurora →
Your path: I want the broadest reductionReverse osmosis at one tap

Reverse osmosis reduces many dissolved contaminants, including lead and minerals, at a single faucet, with some water sent to drain.

Look forNSF/ANSI 58
Compare treatments →
Questions

Aurora tap water FAQ

Follow Aurora’s water

Get one email when Aurora’s record changes.

Follow Aurora’s water →
Is Aurora tap water safe to drink?

PurityMap does not give a safe/unsafe verdict; it shows what the public records measured. For Aurora, PFAS were detected below their limits, and PFBA 5.9 ng/L and PFPeA 5.3 ng/L with no federal or state limit; the lead 90th-percentile result was 25.7 µg/L against the 15 µg/L action level. AURORA (PWSID IL0894070) has a Purity Score of 63/100 (confidence: moderate), assessed at the water-system level and computed only from contaminants that were measured. Water can change in your own pipes, so a certified test is the only way to know what comes out of your tap. What we found →

Who provides tap water in Aurora?

AURORA (PWS ID IL0894070) is the public water system on record for Aurora, Illinois, serving about 183,000 people. Confirm the utility on your water bill before acting on a specific finding. Water utility →

Where does Aurora get its drinking water?

Surface water (primary source of record in EPA SDWIS). Water utility →

Are PFAS "forever chemicals" in Aurora's water?

In EPA's UCMR 5 testing (2024-05-22 to 2025-02-11), PFBS was detected at 3.7 ng/L, below the 2,000 ng/L EPA health advisory and PFHxA was detected at 4.7 ng/L, below the 400,000 ng/L state limit. PFBA (5.9 ng/L) and PFPeA (5.3 ng/L) were also detected; they have no federal or state limit. What we found →

Is there lead in Aurora's tap water?

AURORA's most recent lead 90th-percentile result (2026) was 25.7 µg/L, above the 15 µg/L action level. That figure comes from sampled homes; lead usually enters from a building's own pipes and fixtures, so only a test at your tap tells you what you drink. Your household →

What does the latest Aurora water report show?

PurityMap's current record for Aurora holds 32 findings: 3 above a reference, 2 detected within the reference, 2 detected with no limit and 25 not detected. Each finding links to its dated public record; a parameter that was never monitored is shown as pending, not as a pass. Records →

Is Aurora's water hard?

Aurora's water is recorded as 7.9 gpg, hard. Hardness is an aesthetic and plumbing characteristic, not a health-based limit. Choose your situation →

Data and sources

32 records, each traceable

  • EPA UCMR 5
  • EPA SDWIS (Lead & Copper Rule)
  • Utility CCR
ContaminantMeasuredReferenceSampledSource
Lithium18.6 µg/L10 µg/L EPA health reference level (screening, not a legal limit)2024–2025EPA UCMR 5 ↗ (opens in a new tab)
Lead (90th percentile)25.7 µg/L15 µg/L federal action level2026EPA SDWIS (Lead & Copper Rule) ↗ (opens in a new tab)
Water hardness7.9 gpgAesthetic, no federal health limit2025Utility CCR ↗ (opens in a new tab)
Perfluorobutanesulfonic acid (PFBS)3.7 ng/L2,000 ng/L EPA health advisory (screening, not a legal limit)2024–2025EPA UCMR 5 ↗ (opens in a new tab)
Perfluorohexanoic acid (PFHxA)4.7 ng/L400,000 ng/L Michigan EGLE state MCL (strictest US state)2024–2025EPA UCMR 5 ↗ (opens in a new tab)
Perfluorobutanoic acid (PFBA)5.9 ng/LNo federal or state limit; shown for transparency2024–2025EPA UCMR 5 ↗ (opens in a new tab)
Perfluoropentanoic acid (PFPeA)5.3 ng/LNo federal or state limit; shown for transparency2024–2025EPA UCMR 5 ↗ (opens in a new tab)
11-Chloroeicosafluoro-3-oxaundecane-1-sulfonic acid (11Cl-PF3OUdS)< 5 ng/L (not detected)No federal or state limit; shown for transparency2024–2025EPA UCMR 5 ↗ (opens in a new tab)
1H, 1H, 2H, 2H-perfluorodecane sulfonic acid (8:2 FTS)< 5 ng/L (not detected)No federal or state limit; shown for transparency2024–2025EPA UCMR 5 ↗ (opens in a new tab)
1H, 1H, 2H, 2H-perfluorohexane sulfonic acid (4:2 FTS)< 3 ng/L (not detected)No federal or state limit; shown for transparency2024–2025EPA UCMR 5 ↗ (opens in a new tab)
1H, 1H, 2H, 2H-perfluorooctane sulfonic acid (6:2 FTS)< 5 ng/L (not detected)No federal or state limit; shown for transparency2024–2025EPA UCMR 5 ↗ (opens in a new tab)
4,8-Dioxa-3H-perfluorononanoic acid (ADONA)< 3 ng/L (not detected)No federal or state limit; shown for transparency2024–2025EPA UCMR 5 ↗ (opens in a new tab)
9-Chlorohexadecafluoro-3-oxanone-1-sulfonic acid (9Cl-PF3ONS)< 2 ng/L (not detected)No federal or state limit; shown for transparency2024–2025EPA UCMR 5 ↗ (opens in a new tab)
Hexafluoropropylene oxide dimer acid (HFPO-DA) (GenX chemicals)< 5 ng/L (not detected)10 ng/L federal MCL (2024)2024–2025EPA UCMR 5 ↗ (opens in a new tab)
N-ethyl perfluorooctanesulfonamidoacetic acid (NEtFOSAA)< 5 ng/L (not detected)No federal or state limit; shown for transparency2024–2025EPA UCMR 5 ↗ (opens in a new tab)
N-methyl perfluorooctanesulfonamidoacetic acid (NMeFOSAA)< 6 ng/L (not detected)No federal or state limit; shown for transparency2024–2025EPA UCMR 5 ↗ (opens in a new tab)
Nonafluoro-3,6-dioxaheptanoic acid (NFDHA)< 20 ng/L (not detected)No federal or state limit; shown for transparency2024–2025EPA UCMR 5 ↗ (opens in a new tab)
Perfluoro (2-ethoxyethane) sulfonic acid (PFEESA)< 3 ng/L (not detected)No federal or state limit; shown for transparency2024–2025EPA UCMR 5 ↗ (opens in a new tab)
Perfluoro-3-methoxypropanoic acid (PFMPA)< 4 ng/L (not detected)No federal or state limit; shown for transparency2024–2025EPA UCMR 5 ↗ (opens in a new tab)
Perfluoro-4-methoxybutanoic acid (PFMBA)< 3 ng/L (not detected)No federal or state limit; shown for transparency2024–2025EPA UCMR 5 ↗ (opens in a new tab)
Perfluorodecanoic acid (PFDA)< 3 ng/L (not detected)No federal or state limit; shown for transparency2024–2025EPA UCMR 5 ↗ (opens in a new tab)
Perfluorododecanoic acid (PFDoA)< 3 ng/L (not detected)No federal or state limit; shown for transparency2024–2025EPA UCMR 5 ↗ (opens in a new tab)
Perfluoroheptanesulfonic acid (PFHpS)< 3 ng/L (not detected)No federal or state limit; shown for transparency2024–2025EPA UCMR 5 ↗ (opens in a new tab)
Perfluoroheptanoic acid (PFHpA)< 3 ng/L (not detected)No federal or state limit; shown for transparency2024–2025EPA UCMR 5 ↗ (opens in a new tab)
Perfluorohexanesulfonic acid (PFHxS)< 3 ng/L (not detected)10 ng/L federal MCL (2024)2024–2025EPA UCMR 5 ↗ (opens in a new tab)
Perfluorononanoic acid (PFNA)< 4 ng/L (not detected)10 ng/L federal MCL (2024)2024–2025EPA UCMR 5 ↗ (opens in a new tab)
Perfluorooctanesulfonic acid (PFOS)< 4 ng/L (not detected)4.0 ng/L federal MCL (2024)2024–2025EPA UCMR 5 ↗ (opens in a new tab)
Perfluorooctanoic acid (PFOA)< 4 ng/L (not detected)4.0 ng/L federal MCL (2024)2024–2025EPA UCMR 5 ↗ (opens in a new tab)
Perfluoropentanesulfonic acid (PFPeS)< 4 ng/L (not detected)No federal or state limit; shown for transparency2024–2025EPA UCMR 5 ↗ (opens in a new tab)
Perfluorotetradecanoic acid (PFTA)< 8 ng/L (not detected)No federal or state limit; shown for transparency2024–2025EPA UCMR 5 ↗ (opens in a new tab)
Perfluorotridecanoic acid (PFTrDA)< 7 ng/L (not detected)No federal or state limit; shown for transparency2024–2025EPA UCMR 5 ↗ (opens in a new tab)
Perfluoroundecanoic acid (PFUnA)< 2 ng/L (not detected)No federal or state limit; shown for transparency2024–2025EPA UCMR 5 ↗ (opens in a new tab)
  • UCMR5 Analytical Results

    UCMR5 Analytical Results: AURORA (IL0894070)

    US EPA

    Published
    2026-10-15
    Newest sample
    2025-02-11
    Findings here
    30
  • State SDWIS Compliance Record

    Lead & Copper Rule 90th-percentile: AURORA (IL0894070)

    US EPA SDWIS

    Published
    2026-10-13
    Newest sample
    2026
    Findings here
    1
  • Consumer Confidence Report (CCR)

    City of Aurora, Illinois - Water Production Division 2025 Consumer Confidence Report (CCR)

    City of Aurora, Illinois - Water Production Division

    Published
    2025-01-01
    Newest sample
    2025
    Findings here
    1

Methodology: how we analyze water. Prepared with AI assistance and reviewed by the PurityMap Editorial Team before publication.

Methodology

How PurityMap reads Aurora’s water

  1. 01Source data

    EPA SDWIS, EPA UCMR 5 and utility reports, each dated and linked.

  2. 02Normalize

    Units converted to one basis; a non-detect kept distinct from zero.

  3. 03Classify

    Each result tagged by reference type: MCL, action level, screening level or aesthetic.

  4. 04Compare to the named reference

    Every value sits against its own reference, never a blended one.

  5. 05Score

    Measured subjects summarised at the water-system level; an open health-based violation caps the score.

  6. 06Match treatment

    Treatment is matched to what was found; a product is called certified only when its current certification names it.

What the Purity Score means: a summary of this water system’s published record, capped while a health-based violation is open. It is not a test of any tap. AURORA · PWSID IL0894070 · Purity Score 63/100 (Fair) · Confidence: moderate · Assessed at the water-system level

Full methodology →

Something off with your water's smell, color or taste?

Start with the hot-or-cold tap check. Where City of Aurora reported something related, it's shown below.

ZIP codes in Aurora

Look up water quality by ZIP code →