Forensic evidence record · ev-az0413048-f-prescott-valley-lithium
Lithium
A single published measurement record with its qualifier, sampling context, source identifier, method note, and stated limitations kept together.
Published evidence record
24.7 µg/LReported measurementSource observations (38)
- lithium — Sample date: 2024-03-27
Below reporting limit. < Result value not available µg/L
Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable
Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 380-89000-1 · Method EPA 200.7
- lithium — Sample date: 2024-09-19
Below reporting limit. < Result value not available µg/L
Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable
Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 380-114082-1 · Method EPA 200.7
- lithium — Sample date: 2024-03-19
Below reporting limit. < Result value not available µg/L
Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable
Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 380-88043-2 · Method EPA 200.7
- lithium — Sample date: 2024-09-19
Below reporting limit. < Result value not available µg/L
Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable
Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 380-114082-8 · Method EPA 200.7
- lithium — Sample date: 2024-03-12
Below reporting limit. < Result value not available µg/L
Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable
Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 380-87060-3 · Method EPA 200.7
- lithium — Sample date: 2024-09-11
Below reporting limit. < Result value not available µg/L
Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable
Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 380-112897-1 · Method EPA 200.7
- lithium — Sample date: 2024-03-19
Below reporting limit. < Result value not available µg/L
Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable
Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 380-88043-3 · Method EPA 200.7
- lithium — Sample date: 2024-09-11
Below reporting limit. < Result value not available µg/L
Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable
Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 380-112897-2 · Method EPA 200.7
- lithium — Sample date: 2024-03-19
Detected above reporting limit. = 24.7 µg/L
Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable
Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 380-88043-4 · Method EPA 200.7
- lithium — Sample date: 2024-09-19
Detected above reporting limit. = 22 µg/L
Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable
Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 380-114082-6 · Method EPA 200.7
- lithium — Sample date: 2024-03-12
Below reporting limit. < Result value not available µg/L
Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable
Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 380-87060-4 · Method EPA 200.7
- lithium — Sample date: 2024-09-11
Below reporting limit. < Result value not available µg/L
Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable
Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 380-112897-4 · Method EPA 200.7
- lithium — Sample date: 2025-06-03
Below reporting limit. < Result value not available µg/L
Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable
Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 380-153843-1 · Method EPA 200.7
- lithium — Sample date: 2025-12-03
Below reporting limit. < Result value not available µg/L
Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable
Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 380-186284-1 · Method EPA 200.7
- lithium — Sample date: 2024-03-12
Detected at or below reporting limit. = 9 µg/L
Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable
Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 380-87060-5 · Method EPA 200.7
- lithium — Sample date: 2024-09-11
Detected above reporting limit. = 9.95 µg/L
Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable
Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 380-112897-5 · Method EPA 200.7
- lithium — Sample date: 2024-03-27
Below reporting limit. < Result value not available µg/L
Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable
Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 380-89000-2 · Method EPA 200.7
- lithium — Sample date: 2024-09-11
Below reporting limit. < Result value not available µg/L
Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable
Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 380-112897-6 · Method EPA 200.7
- lithium — Sample date: 2024-03-19
Below reporting limit. < Result value not available µg/L
Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable
Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 380-88043-5 · Method EPA 200.7
- lithium — Sample date: 2024-09-19
Below reporting limit. < Result value not available µg/L
Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable
Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 380-114082-3 · Method EPA 200.7
- lithium — Sample date: 2024-03-12
Below reporting limit. < Result value not available µg/L
Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable
Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 380-87060-6 · Method EPA 200.7
- lithium — Sample date: 2024-09-11
Below reporting limit. < Result value not available µg/L
Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable
Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 380-112897-7 · Method EPA 200.7
- lithium — Sample date: 2024-03-12
Below reporting limit. < Result value not available µg/L
Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable
Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 380-87060-7 · Method EPA 200.7
- lithium — Sample date: 2024-09-11
Below reporting limit. < Result value not available µg/L
Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable
Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 380-112897-8 · Method EPA 200.7
- lithium — Sample date: 2024-03-12
Below reporting limit. < Result value not available µg/L
Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable
Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 380-87060-8 · Method EPA 200.7
- lithium — Sample date: 2024-09-11
Below reporting limit. < Result value not available µg/L
Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable
Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 380-112897-3 · Method EPA 200.7
- lithium — Sample date: 2024-03-19
Below reporting limit. < Result value not available µg/L
Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable
Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 380-88043-6 · Method EPA 200.7
- lithium — Sample date: 2024-09-19
Below reporting limit. < Result value not available µg/L
Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable
Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 380-114082-9 · Method EPA 200.7
- lithium — Sample date: 2024-03-12
Below reporting limit. < Result value not available µg/L
Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable
Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 380-87060-9 · Method EPA 200.7
- lithium — Sample date: 2024-09-11
Below reporting limit. < Result value not available µg/L
Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable
Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 380-112897-9 · Method EPA 200.7
- lithium — Sample date: 2024-03-12
Below reporting limit. < Result value not available µg/L
Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable
Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 380-87060-1 · Method EPA 200.7
- lithium — Sample date: 2024-09-19
Below reporting limit. < Result value not available µg/L
Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable
Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 380-114082-4 · Method EPA 200.7
- lithium — Sample date: 2024-03-19
Below reporting limit. < Result value not available µg/L
Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable
Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 380-88043-1 · Method EPA 200.7
- lithium — Sample date: 2024-09-19
Below reporting limit. < Result value not available µg/L
Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable
Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 380-114082-5 · Method EPA 200.7
- lithium — Sample date: 2024-03-25
Below reporting limit. < Result value not available µg/L
Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable
Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 380-88602-2 · Method EPA 200.7
- lithium — Sample date: 2024-09-19
Below reporting limit. < Result value not available µg/L
Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable
Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 380-114082-7 · Method EPA 200.7
- lithium — Sample date: 2024-03-12
Below reporting limit. < Result value not available µg/L
Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable
Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 380-87060-2 · Method EPA 200.7
- lithium — Sample date: 2024-09-19
Below reporting limit. < Result value not available µg/L
Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable
Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 380-114082-2 · Method EPA 200.7
Measurement evidence
- Analyte
- Lithium
- Result qualifier
- =
- Reference basis
- 10.0 µg/L EPA health reference level (screening, not a legal limit)
- Sampling location
- Entry Point to Distribution
- Water system ID
- AZ0413048
- Source ID
- src-ucmr5-2024
Laboratory context
No laboratory method note was published with this record.
Sampling context
This result represents a entry point to distribution sample. It does not establish the condition at every distribution point or household tap.
Record limitation
System-level entry-point monitoring; not a measurement of the water at an individual household tap.
Source provenance
UCMR5 Analytical Results
Fifth Unregulated Contaminant Monitoring Rule (UCMR5) — PFAS occurrence data
U.S. Environmental Protection Agency · Published 2024
Nationwide entry-point monitoring for 29 PFAS and lithium under the fifth UCMR cycle. Results are entry-point-to-distribution samples, not household-tap measurements.
How to interpret this record
This page preserves one measurement. Interpretation requires its qualifier, reporting limit, reference basis, date, sampling location, and limitations; the number alone is not a safety verdict.
Review finding states →