Published evidence record

9.3 µg/LReported measurement
Back to water-system profile
9.3 µg/Lreported result
Not verified from sourcereporting limit
Sample date: 2023-03-08 to 2023-12-06sample date
2026-10-15publication date
Source observations (16)
  • lithium — Sample date: 2023-03-08

    Detected above reporting limit. = 9.3 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample EP#28 WELL 21 TREATED · Method EPA 200.7

  • lithium — Sample date: 2023-09-06

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 2309506-001A · Method EPA 200.7

  • lithium — Sample date: 2023-03-08

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample EP#26 - WELL 19 TREATED · Method EPA 200.7

  • lithium — Sample date: 2023-09-06

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 2309506-002A · Method EPA 200.7

  • lithium — Sample date: 2023-03-08

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample EP#24 - MIRAMONTE · Method EPA 200.7

  • lithium — Sample date: 2023-06-07

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample EP #24 - MIRAMONTE SE2 · Method EPA 200.7

  • lithium — Sample date: 2023-09-06

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 2309506-003A · Method EPA 200.7

  • lithium — Sample date: 2023-12-06

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 2312567-001A · Method EPA 200.7

  • lithium — Sample date: 2023-03-08

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample EP#23 - ESCUELA #5 · Method EPA 200.7

  • lithium — Sample date: 2023-06-07

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample EP #23 - ESCUELA #5 SE2 · Method EPA 200.7

  • lithium — Sample date: 2023-09-06

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 2309506-004A · Method EPA 200.7

  • lithium — Sample date: 2023-12-06

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 2312567-002A · Method EPA 200.7

  • lithium — Sample date: 2023-04-21

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample EP #17 -WELL 22 TREATED R · Method EPA 200.7

  • lithium — Sample date: 2023-09-06

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 2309506-005A · Method EPA 200.7

  • lithium — Sample date: 2023-03-08

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample EP#29 WELL 23 TREATED · Method EPA 200.7

  • lithium — Sample date: 2023-09-06

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 2309506-006A · Method EPA 200.7

Measurement evidence

Analyte
Lithium
Result qualifier
=
Reference basis
10.0 µg/L EPA health reference level (screening, not a legal limit)
Sampling location
Entry Point to Distribution
Water system ID
CA4310007
Source ID
src-ucmr5-2024

Laboratory context

No laboratory method note was published with this record.

Sampling context

This result represents a entry point to distribution sample. It does not establish the condition at every distribution point or household tap.

Record limitation

System-level entry-point monitoring; not a measurement of the water at an individual household tap.

Source provenance

UCMR5 Analytical Results

Fifth Unregulated Contaminant Monitoring Rule (UCMR5) — PFAS occurrence data

U.S. Environmental Protection Agency · Published 2024

Nationwide entry-point monitoring for 29 PFAS and lithium under the fifth UCMR cycle. Results are entry-point-to-distribution samples, not household-tap measurements.

How to interpret this record

This page preserves one measurement. Interpretation requires its qualifier, reporting limit, reference basis, date, sampling location, and limitations; the number alone is not a safety verdict.

Review finding states →

Related intelligence