Forensic evidence record · ev-co0101025-f-brighton-pfbs

Perfluorobutanesulfonic acid (PFBS)

A single published measurement record with its qualifier, sampling context, source identifier, method note, and stated limitations kept together.

Published evidence record

7.4 ng/LReported measurement
Back to water-system profile
7.4 ng/Lreported result
Not verified from sourcereporting limit
Sample date: 2024-01-17 to 2025-08-19sample date
2026-10-15publication date
Source observations (16)
  • PFBS — Sample date: 2024-01-17

    Detected above reporting limit. = 0.0055 µg/L

    Reporting limit: 0.003 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample K2400555-001 · Method EPA 533

  • PFBS — Sample date: 2024-04-24

    Detected above reporting limit. = 0.0054 µg/L

    Reporting limit: 0.003 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample K2404211-001 · Method EPA 533

  • PFBS — Sample date: 2024-07-11

    Detected above reporting limit. = 0.0074 µg/L

    Reporting limit: 0.003 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample K2407224-001 · Method EPA 533

  • PFBS — Sample date: 2024-10-08

    Detected above reporting limit. = 0.0066 µg/L

    Reporting limit: 0.003 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample K2410838-001 · Method EPA 533

  • PFBS — Sample date: 2024-01-17

    Detected above reporting limit. = 0.0056 µg/L

    Reporting limit: 0.003 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample K2400555-003 · Method EPA 533

  • PFBS — Sample date: 2024-04-24

    Detected above reporting limit. = 0.0053 µg/L

    Reporting limit: 0.003 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample K2404211-003 · Method EPA 533

  • PFBS — Sample date: 2024-07-11

    Detected above reporting limit. = 0.0074 µg/L

    Reporting limit: 0.003 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample K2407224-003 · Method EPA 533

  • PFBS — Sample date: 2024-10-08

    Detected above reporting limit. = 0.0063 µg/L

    Reporting limit: 0.003 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample K2410838-003 · Method EPA 533

  • PFBS — Sample date: 2024-01-17

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 0.003 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample K2400555-005 · Method EPA 533

  • PFBS — Sample date: 2024-04-24

    Detected above reporting limit. = 0.0036 µg/L

    Reporting limit: 0.003 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample K2404211-005 · Method EPA 533

  • PFBS — Sample date: 2024-07-11

    Detected above reporting limit. = 0.0031 µg/L

    Reporting limit: 0.003 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample K2407224-005 · Method EPA 533

  • PFBS — Sample date: 2024-10-08

    Detected above reporting limit. = 0.0031 µg/L

    Reporting limit: 0.003 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample K2410838-005 · Method EPA 533

  • PFBS — Sample date: 2024-08-23

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 0.003 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample K2408844-001 · Method EPA 533

  • PFBS — Sample date: 2025-07-10

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 0.003 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample K2506905-001 · Method EPA 533

  • PFBS — Sample date: 2024-07-11

    Detected above reporting limit. = 0.0031 µg/L

    Reporting limit: 0.003 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample K2407224-007 · Method EPA 533

  • PFBS — Sample date: 2025-08-19

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 0.003 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 25080146-01 · Method EPA 533

Measurement evidence

Analyte
Perfluorobutanesulfonic acid (PFBS)
Result qualifier
=
Reference basis
2000.0 ng/L EPA health advisory (screening, not a legal limit)
Sampling location
Entry Point to Distribution
Water system ID
CO0101025
Source ID
src-ucmr5-2024

Laboratory context

No laboratory method note was published with this record.

Sampling context

This result represents a entry point to distribution sample. It does not establish the condition at every distribution point or household tap.

Record limitation

System-level entry-point monitoring; not a measurement of the water at an individual household tap.

Source provenance

UCMR5 Analytical Results

Fifth Unregulated Contaminant Monitoring Rule (UCMR5) — PFAS occurrence data

U.S. Environmental Protection Agency · Published 2024

Nationwide entry-point monitoring for 29 PFAS and lithium under the fifth UCMR cycle. Results are entry-point-to-distribution samples, not household-tap measurements.

How to interpret this record

This page preserves one measurement. Interpretation requires its qualifier, reporting limit, reference basis, date, sampling location, and limitations; the number alone is not a safety verdict.

Review finding states →

Related intelligence