Forensic evidence record · ev-co0121275-f-fountain-lithium

Lithium

A single published measurement record with its qualifier, sampling context, source identifier, method note, and stated limitations kept together.

Published evidence record

63.3 µg/LReported measurement
Back to water-system profile
63.3 µg/Lreported result
Not verified from sourcereporting limit
Sample date: 2025-01-08 to 2025-10-06sample date
2026-10-15publication date
Source observations (14)
  • lithium — Sample date: 2025-01-08

    Detected above reporting limit. = 13.6 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 810-133797-1 · Method EPA 200.7

  • lithium — Sample date: 2025-04-09

    Detected above reporting limit. = 15.3 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 810-144336-1 · Method EPA 200.7

  • lithium — Sample date: 2025-07-08

    Detected above reporting limit. = 13.9 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 810-154896-1 · Method EPA 200.7

  • lithium — Sample date: 2025-10-06

    Detected above reporting limit. = 14.5 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 810-166991-1 · Method EPA 200.7

  • lithium — Sample date: 2025-01-08

    Detected above reporting limit. = 26.8 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 810-133830-1 · Method EPA 200.7

  • lithium — Sample date: 2025-04-09

    Detected above reporting limit. = 22.7 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 810-144339-1 · Method EPA 200.7

  • lithium — Sample date: 2025-07-08

    Detected above reporting limit. = 19.9 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 810-154893-1 · Method EPA 200.7

  • lithium — Sample date: 2025-10-06

    Detected above reporting limit. = 20.9 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 810-166994-1 · Method EPA 200.7

  • lithium — Sample date: 2025-01-08

    Detected above reporting limit. = 30.3 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 810-133836-1 · Method EPA 200.7

  • lithium — Sample date: 2025-04-09

    Detected above reporting limit. = 24.2 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 810-144340-1 · Method EPA 200.7

  • lithium — Sample date: 2025-07-08

    Detected above reporting limit. = 33.3 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 810-154898-1 · Method EPA 200.7

  • lithium — Sample date: 2025-10-06

    Detected above reporting limit. = 20.6 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 810-166987-1 · Method EPA 200.7

  • lithium — Sample date: 2025-01-08

    Detected above reporting limit. = 61 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 810-133843-1 · Method EPA 200.7

  • lithium — Sample date: 2025-07-22

    Detected above reporting limit. = 63.3 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 810-156833-1 · Method EPA 200.7

Measurement evidence

Analyte
Lithium
Result qualifier
=
Reference basis
10.0 µg/L EPA health reference level (screening, not a legal limit)
Sampling location
Entry Point to Distribution
Water system ID
CO0121275
Source ID
src-ucmr5-2024

Laboratory context

No laboratory method note was published with this record.

Sampling context

This result represents a entry point to distribution sample. It does not establish the condition at every distribution point or household tap.

Record limitation

System-level entry-point monitoring; not a measurement of the water at an individual household tap.

Source provenance

UCMR5 Analytical Results

Fifth Unregulated Contaminant Monitoring Rule (UCMR5) — PFAS occurrence data

U.S. Environmental Protection Agency · Published 2024

Nationwide entry-point monitoring for 29 PFAS and lithium under the fifth UCMR cycle. Results are entry-point-to-distribution samples, not household-tap measurements.

How to interpret this record

This page preserves one measurement. Interpretation requires its qualifier, reporting limit, reference basis, date, sampling location, and limitations; the number alone is not a safety verdict.

Review finding states →