Forensic evidence record · ev-ga1690002-f-jones-county-pfbs
Perfluorobutanesulfonic acid (PFBS)
A single published measurement record with its qualifier, sampling context, source identifier, method note, and stated limitations kept together.
Published evidence record
4.4 ng/LReported measurementSource observations (14)
- PFBS — Sample date: 2023-12-05
Below reporting limit. < Result value not available µg/L
Reporting limit: 0.003 µg/L. Detection limit: Not available. Benchmark unavailable
Source: src-ucmr5-2024 · UCMR5_All.txt · Sample J2313637011 · Method EPA 533
- PFBS — Sample date: 2024-03-06
Below reporting limit. < Result value not available µg/L
Reporting limit: 0.003 µg/L. Detection limit: Not available. Benchmark unavailable
Source: src-ucmr5-2024 · UCMR5_All.txt · Sample J2403604001 · Method EPA 533
- PFBS — Sample date: 2023-12-05
Below reporting limit. < Result value not available µg/L
Reporting limit: 0.003 µg/L. Detection limit: Not available. Benchmark unavailable
Source: src-ucmr5-2024 · UCMR5_All.txt · Sample J2313637013 · Method EPA 533
- PFBS — Sample date: 2024-07-09
Below reporting limit. < Result value not available µg/L
Reporting limit: 0.003 µg/L. Detection limit: Not available. Benchmark unavailable
Source: src-ucmr5-2024 · UCMR5_All.txt · Sample J2409918001 · Method EPA 533
- PFBS — Sample date: 2023-12-05
Below reporting limit. < Result value not available µg/L
Reporting limit: 0.003 µg/L. Detection limit: Not available. Benchmark unavailable
Source: src-ucmr5-2024 · UCMR5_All.txt · Sample J2313637015 · Method EPA 533
- PFBS — Sample date: 2024-08-26
Below reporting limit. < Result value not available µg/L
Reporting limit: 0.003 µg/L. Detection limit: Not available. Benchmark unavailable
Source: src-ucmr5-2024 · UCMR5_All.txt · Sample J2412504001 · Method EPA 533
- PFBS — Sample date: 2023-12-05
Below reporting limit. < Result value not available µg/L
Reporting limit: 0.003 µg/L. Detection limit: Not available. Benchmark unavailable
Source: src-ucmr5-2024 · UCMR5_All.txt · Sample J2313637017 · Method EPA 533
- PFBS — Sample date: 2024-03-06
Below reporting limit. < Result value not available µg/L
Reporting limit: 0.003 µg/L. Detection limit: Not available. Benchmark unavailable
Source: src-ucmr5-2024 · UCMR5_All.txt · Sample J2403604007 · Method EPA 533
- PFBS — Sample date: 2023-09-18
Detected above reporting limit. = 0.0044 µg/L
Reporting limit: 0.003 µg/L. Detection limit: Not available. Benchmark unavailable
Source: src-ucmr5-2024 · UCMR5_All.txt · Sample J2313634001 · Method EPA 533
- PFBS — Sample date: 2024-03-06
Below reporting limit. < Result value not available µg/L
Reporting limit: 0.003 µg/L. Detection limit: Not available. Benchmark unavailable
Source: src-ucmr5-2024 · UCMR5_All.txt · Sample J2318193003 · Method EPA 533
- PFBS — Sample date: 2024-07-09
Below reporting limit. < Result value not available µg/L
Reporting limit: 0.003 µg/L. Detection limit: Not available. Benchmark unavailable
Source: src-ucmr5-2024 · UCMR5_All.txt · Sample J2409988001 · Method EPA 533
- PFBS — Sample date: 2024-07-23
Below reporting limit. < Result value not available µg/L
Reporting limit: 0.003 µg/L. Detection limit: Not available. Benchmark unavailable
Source: src-ucmr5-2024 · UCMR5_All.txt · Sample J2410733001 · Method EPA 533
- PFBS — Sample date: 2023-12-05
Below reporting limit. < Result value not available µg/L
Reporting limit: 0.003 µg/L. Detection limit: Not available. Benchmark unavailable
Source: src-ucmr5-2024 · UCMR5_All.txt · Sample J2313637019 · Method EPA 533
- PFBS — Sample date: 2024-03-06
Below reporting limit. < Result value not available µg/L
Reporting limit: 0.003 µg/L. Detection limit: Not available. Benchmark unavailable
Source: src-ucmr5-2024 · UCMR5_All.txt · Sample J2403604009 · Method EPA 533
Measurement evidence
- Analyte
- Perfluorobutanesulfonic acid (PFBS)
- Result qualifier
- =
- Reference basis
- 2000.0 ng/L EPA health advisory (screening, not a legal limit)
- Sampling location
- Entry Point to Distribution
- Water system ID
- GA1690002
- Source ID
- src-ucmr5-2024
Laboratory context
No laboratory method note was published with this record.
Sampling context
This result represents a entry point to distribution sample. It does not establish the condition at every distribution point or household tap.
Record limitation
System-level entry-point monitoring; not a measurement of the water at an individual household tap.
Source provenance
UCMR5 Analytical Results
Fifth Unregulated Contaminant Monitoring Rule (UCMR5) — PFAS occurrence data
U.S. Environmental Protection Agency · Published 2024
Nationwide entry-point monitoring for 29 PFAS and lithium under the fifth UCMR cycle. Results are entry-point-to-distribution samples, not household-tap measurements.
How to interpret this record
This page preserves one measurement. Interpretation requires its qualifier, reporting limit, reference basis, date, sampling location, and limitations; the number alone is not a safety verdict.
Review finding states →