Forensic evidence record · ev-il1970900-f-romeoville-lithium
Lithium
A single published measurement record with its qualifier, sampling context, source identifier, method note, and stated limitations kept together.
Published evidence record
54.6 µg/LReported measurementSource observations (15)
- lithium — Sample date: 2024-06-13
Detected above reporting limit. = 24.6 µg/L
Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable
Source: src-ucmr5-2024 · UCMR5_All.txt · Sample AAG0384-05 · Method EPA 200.7
- lithium — Sample date: 2024-12-12
Detected above reporting limit. = 35.4 µg/L
Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable
Source: src-ucmr5-2024 · UCMR5_All.txt · Sample AAL0838-05 · Method EPA 200.7
- lithium — Sample date: 2024-06-13
Detected above reporting limit. = 24.8 µg/L
Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable
Source: src-ucmr5-2024 · UCMR5_All.txt · Sample AAG0384-10 · Method EPA 200.7
- lithium — Sample date: 2024-12-12
Detected above reporting limit. = 47.4 µg/L
Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable
Source: src-ucmr5-2024 · UCMR5_All.txt · Sample AAL0839-05 · Method EPA 200.7
- lithium — Sample date: 2024-06-13
Detected above reporting limit. = 18.1 µg/L
Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable
Source: src-ucmr5-2024 · UCMR5_All.txt · Sample AAG0384-15 · Method EPA 200.7
- lithium — Sample date: 2024-12-12
Detected above reporting limit. = 25.6 µg/L
Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable
Source: src-ucmr5-2024 · UCMR5_All.txt · Sample AAL0840-05 · Method EPA 200.7
- lithium — Sample date: 2024-06-13
Detected above reporting limit. = 34.8 µg/L
Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable
Source: src-ucmr5-2024 · UCMR5_All.txt · Sample AAG0384-20 · Method EPA 200.7
- lithium — Sample date: 2024-06-13
Detected above reporting limit. = 18.4 µg/L
Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable
Source: src-ucmr5-2024 · UCMR5_All.txt · Sample AAG0384-25 · Method EPA 200.7
- lithium — Sample date: 2024-12-12
Detected above reporting limit. = 25.7 µg/L
Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable
Source: src-ucmr5-2024 · UCMR5_All.txt · Sample AAL0841-05 · Method EPA 200.7
- lithium — Sample date: 2024-06-13
Detected above reporting limit. = 27.4 µg/L
Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable
Source: src-ucmr5-2024 · UCMR5_All.txt · Sample AAG0384-30 · Method EPA 200.7
- lithium — Sample date: 2024-12-12
Detected above reporting limit. = 41.6 µg/L
Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable
Source: src-ucmr5-2024 · UCMR5_All.txt · Sample AAL0842-05 · Method EPA 200.7
- lithium — Sample date: 2024-12-12
Detected above reporting limit. = 54.6 µg/L
Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable
Source: src-ucmr5-2024 · UCMR5_All.txt · Sample AAL0843-05 · Method EPA 200.7
- lithium — Sample date: 2025-06-09
Detected above reporting limit. = 41.4 µg/L
Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable
Source: src-ucmr5-2024 · UCMR5_All.txt · Sample ABF0593-05 · Method EPA 200.7
- lithium — Sample date: 2024-12-12
Detected above reporting limit. = 53 µg/L
Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable
Source: src-ucmr5-2024 · UCMR5_All.txt · Sample AAL0844-05 · Method EPA 200.7
- lithium — Sample date: 2025-06-09
Detected above reporting limit. = 30.8 µg/L
Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable
Source: src-ucmr5-2024 · UCMR5_All.txt · Sample ABF0593-10 · Method EPA 200.7
Measurement evidence
- Analyte
- Lithium
- Result qualifier
- =
- Reference basis
- 10.0 µg/L EPA health reference level (screening, not a legal limit)
- Sampling location
- Entry Point to Distribution
- Water system ID
- IL1970900
- Source ID
- src-ucmr5-2024
Laboratory context
No laboratory method note was published with this record.
Sampling context
This result represents a entry point to distribution sample. It does not establish the condition at every distribution point or household tap.
Record limitation
System-level entry-point monitoring; not a measurement of the water at an individual household tap.
Source provenance
UCMR5 Analytical Results
Fifth Unregulated Contaminant Monitoring Rule (UCMR5) — PFAS occurrence data
U.S. Environmental Protection Agency · Published 2024
Nationwide entry-point monitoring for 29 PFAS and lithium under the fifth UCMR cycle. Results are entry-point-to-distribution samples, not household-tap measurements.
How to interpret this record
This page preserves one measurement. Interpretation requires its qualifier, reporting limit, reference basis, date, sampling location, and limitations; the number alone is not a safety verdict.
Review finding states →