Forensic evidence record · ev-ms0700008-f-ripley-lithium

Lithium

A single published measurement record with its qualifier, sampling context, source identifier, method note, and stated limitations kept together.

Published evidence record

15.8 µg/LReported measurement
Back to water-system profile
15.8 µg/Lreported result
Not verified from sourcereporting limit
Sample date: 2025-02-24 to 2025-08-20sample date
2026-10-15publication date
Source observations (16)
  • lithium — Sample date: 2025-02-24

    Detected above reporting limit. = 15.8 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 810-139164-1 · Method EPA 200.7

  • lithium — Sample date: 2025-08-20

    Detected above reporting limit. = 11.2 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 810-160915-1 · Method EPA 200.7

  • lithium — Sample date: 2025-02-24

    Detected above reporting limit. = 9.31 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 810-139172-1 · Method EPA 200.7

  • lithium — Sample date: 2025-08-20

    Detected above reporting limit. = 9.19 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 810-160904-1 · Method EPA 200.7

  • lithium — Sample date: 2025-02-24

    Detected above reporting limit. = 14.9 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 810-139175-1 · Method EPA 200.7

  • lithium — Sample date: 2025-08-20

    Detected above reporting limit. = 15.3 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 810-160905-1 · Method EPA 200.7

  • lithium — Sample date: 2025-02-24

    Detected above reporting limit. = 13.6 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 810-139169-1 · Method EPA 200.7

  • lithium — Sample date: 2025-08-20

    Detected above reporting limit. = 11.4 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 810-160917-1 · Method EPA 200.7

  • lithium — Sample date: 2025-02-24

    Detected above reporting limit. = 9.27 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 810-139173-1 · Method EPA 200.7

  • lithium — Sample date: 2025-08-20

    Detected above reporting limit. = 9.42 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 810-160911-1 · Method EPA 200.7

  • lithium — Sample date: 2025-02-24

    Detected above reporting limit. = 15.6 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 810-139176-1 · Method EPA 200.7

  • lithium — Sample date: 2025-08-20

    Detected above reporting limit. = 15.3 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 810-160908-1 · Method EPA 200.7

  • lithium — Sample date: 2025-02-24

    Detected above reporting limit. = 15.7 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 810-139162-1 · Method EPA 200.7

  • lithium — Sample date: 2025-08-20

    Detected above reporting limit. = 11.5 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 810-160919-1 · Method EPA 200.7

  • lithium — Sample date: 2025-02-24

    Detected above reporting limit. = 9.68 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 810-139160-1 · Method EPA 200.7

  • lithium — Sample date: 2025-08-20

    Detected above reporting limit. = 9.79 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 810-160913-1 · Method EPA 200.7

Measurement evidence

Analyte
Lithium
Result qualifier
=
Reference basis
10.0 µg/L EPA health reference level (screening, not a legal limit)
Sampling location
Entry Point to Distribution
Water system ID
MS0700008
Source ID
src-ucmr5-2024

Laboratory context

No laboratory method note was published with this record.

Sampling context

This result represents a entry point to distribution sample. It does not establish the condition at every distribution point or household tap.

Record limitation

System-level entry-point monitoring; not a measurement of the water at an individual household tap.

Source provenance

UCMR5 Analytical Results

Fifth Unregulated Contaminant Monitoring Rule (UCMR5) — PFAS occurrence data

U.S. Environmental Protection Agency · Published 2024

Nationwide entry-point monitoring for 29 PFAS and lithium under the fifth UCMR cycle. Results are entry-point-to-distribution samples, not household-tap measurements.

How to interpret this record

This page preserves one measurement. Interpretation requires its qualifier, reporting limit, reference basis, date, sampling location, and limitations; the number alone is not a safety verdict.