Forensic evidence record · ev-nm3525332-f-los-lunas-lithium
Lithium
A single published measurement record with its qualifier, sampling context, source identifier, method note, and stated limitations kept together.
Published evidence record
34 µg/LReported measurementSource observations (10)
- lithium — Sample date: 2025-02-18
Detected above reporting limit. = 23 µg/L
Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable
Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 380-137031-1 · Method EPA 200.7
- lithium — Sample date: 2025-08-18
Detected above reporting limit. = 24 µg/L
Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable
Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 885-31326-1 · Method EPA 200.7
- lithium — Sample date: 2023-08-28
Detected above reporting limit. = 31.2 µg/L
Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable
Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 2023036715 · Method EPA 200.7
- lithium — Sample date: 2025-02-18
Detected above reporting limit. = 34 µg/L
Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable
Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 380-137030-1 · Method EPA 200.7
- lithium — Sample date: 2024-02-27
Detected above reporting limit. = 21.5 µg/L
Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable
Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 2024006383 · Method EPA 200.7
- lithium — Sample date: 2024-08-27
Detected above reporting limit. = 29.6 µg/L
Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable
Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 380-110691-1 · Method EPA 200.7
- lithium — Sample date: 2023-08-28
Detected above reporting limit. = 24.6 µg/L
Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable
Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 2023036714 · Method EPA 200.7
- lithium — Sample date: 2024-02-27
Detected above reporting limit. = 23.4 µg/L
Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable
Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 2024006384 · Method EPA 200.7
- lithium — Sample date: 2025-02-18
Detected above reporting limit. = 23.7 µg/L
Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable
Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 380-137031-2 · Method EPA 200.7
- lithium — Sample date: 2025-08-18
Detected above reporting limit. = 24 µg/L
Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable
Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 885-31326-3 · Method EPA 200.7
Measurement evidence
- Analyte
- Lithium
- Result qualifier
- =
- Reference basis
- 10.0 µg/L EPA health reference level (screening, not a legal limit)
- Sampling location
- Entry Point to Distribution
- Water system ID
- NM3525332
- Source ID
- src-ucmr5-2024
Laboratory context
No laboratory method note was published with this record.
Sampling context
This result represents a entry point to distribution sample. It does not establish the condition at every distribution point or household tap.
Record limitation
System-level entry-point monitoring; not a measurement of the water at an individual household tap.
Source provenance
UCMR5 Analytical Results
Fifth Unregulated Contaminant Monitoring Rule (UCMR5) — PFAS occurrence data
U.S. Environmental Protection Agency · Published 2024
Nationwide entry-point monitoring for 29 PFAS and lithium under the fifth UCMR cycle. Results are entry-point-to-distribution samples, not household-tap measurements.
How to interpret this record
This page preserves one measurement. Interpretation requires its qualifier, reporting limit, reference basis, date, sampling location, and limitations; the number alone is not a safety verdict.
Review finding states →