46.4 µg/LReported measurement
Back to water-system profile
46.4 µg/Lreported result
Not verified from sourcereporting limit
Sample date: 2024-12-02 to 2025-09-02sample date
2026-10-15publication date
Source observations (26)
  • lithium — Sample date: 2024-12-02

    Detected above reporting limit. = 10.3 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample GL03072-01A · Method EPA 200.7

  • lithium — Sample date: 2025-06-09

    Detected above reporting limit. = 10.8 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample HF10121-05A · Method EPA 200.7

  • lithium — Sample date: 2024-12-02

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample GL03072-03A · Method EPA 200.7

  • lithium — Sample date: 2025-03-03

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample HC04110-01A · Method EPA 200.7

  • lithium — Sample date: 2025-06-09

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample HF10121-01A · Method EPA 200.7

  • lithium — Sample date: 2025-09-02

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample HI02133-01I · Method EPA 200.7

  • lithium — Sample date: 2024-12-02

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample GL03072-05A · Method EPA 200.7

  • lithium — Sample date: 2025-03-03

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample HC04110-03A · Method EPA 200.7

  • lithium — Sample date: 2025-06-09

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample HF10121-03A · Method EPA 200.7

  • lithium — Sample date: 2025-09-02

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample HI02133-03I · Method EPA 200.7

  • lithium — Sample date: 2024-12-02

    Detected above reporting limit. = 20.6 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample GL03072-07A · Method EPA 200.7

  • lithium — Sample date: 2025-06-09

    Detected above reporting limit. = 21.61 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample HF10121-07A · Method EPA 200.7

  • lithium — Sample date: 2024-12-02

    Detected above reporting limit. = 12.2 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample GL03072-09A · Method EPA 200.7

  • lithium — Sample date: 2025-06-09

    Detected above reporting limit. = 13 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample HF10121-09A · Method EPA 200.7

  • lithium — Sample date: 2024-12-02

    Detected above reporting limit. = 40.7 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample GL03072-11A · Method EPA 200.7

  • lithium — Sample date: 2025-06-09

    Detected above reporting limit. = 42.1 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample HF10121-11A · Method EPA 200.7

  • lithium — Sample date: 2024-12-02

    Detected above reporting limit. = 23.3 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample GL03072-13A · Method EPA 200.7

  • lithium — Sample date: 2025-06-09

    Detected above reporting limit. = 23.8 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample HF10121-13A · Method EPA 200.7

  • lithium — Sample date: 2024-12-02

    Detected above reporting limit. = 24.1 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample GL03072-15A · Method EPA 200.7

  • lithium — Sample date: 2025-06-09

    Detected above reporting limit. = 23.5 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample HF10121-15A · Method EPA 200.7

  • lithium — Sample date: 2025-01-06

    Detected above reporting limit. = 39.3 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample HA14118-01A · Method EPA 200.7

  • lithium — Sample date: 2025-06-09

    Detected above reporting limit. = 45.8 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample HF10121-17A · Method EPA 200.7

  • lithium — Sample date: 2024-12-02

    Detected above reporting limit. = 30.8 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample GL03072-19A · Method EPA 200.7

  • lithium — Sample date: 2025-06-09

    Detected above reporting limit. = 34.2 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample HF10121-19A · Method EPA 200.7

  • lithium — Sample date: 2024-12-02

    Detected above reporting limit. = 46.4 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample GL03072-21A · Method EPA 200.7

  • lithium — Sample date: 2025-06-09

    Detected above reporting limit. = 42.8 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample HF10121-21A · Method EPA 200.7

Measurement evidence

Analyte
Lithium
Result qualifier
=
Reference basis
10.0 µg/L EPA health reference level (screening, not a legal limit)
Sampling location
Entry Point to Distribution
Water system ID
OK1010830
Source ID
src-ucmr5-2024

Laboratory context

No laboratory method note was published with this record.

Sampling context

This result represents a entry point to distribution sample. It does not establish the condition at every distribution point or household tap.

Record limitation

System-level entry-point monitoring; not a measurement of the water at an individual household tap.

Source provenance

UCMR5 Analytical Results

Fifth Unregulated Contaminant Monitoring Rule (UCMR5) — PFAS occurrence data

U.S. Environmental Protection Agency · Published 2024

Nationwide entry-point monitoring for 29 PFAS and lithium under the fifth UCMR cycle. Results are entry-point-to-distribution samples, not household-tap measurements.

How to interpret this record

This page preserves one measurement. Interpretation requires its qualifier, reporting limit, reference basis, date, sampling location, and limitations; the number alone is not a safety verdict.

Review finding states →

Related intelligence