Forensic evidence record · ev-sc1820001-f-dcwa-knightsville-sc1820001-pfhxa

Perfluorohexanoic acid (PFHxA)

A single published measurement record with its qualifier, sampling context, source identifier, method note, and stated limitations kept together.

Published evidence record

6.2 ng/LReported measurement
Back to water-system profile
6.2 ng/Lreported result
Not verified from sourcereporting limit
Sample date: 2024-09-11 to 2025-09-24sample date
2026-10-15publication date
Source observations (12)
  • PFHxA — Sample date: 2024-09-11

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 0.003 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 810-119945-1 · Method EPA 533

  • PFHxA — Sample date: 2024-12-16

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 0.003 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 810-131777-1 · Method EPA 533

  • PFHxA — Sample date: 2024-09-11

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 0.003 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 810-119961-1 · Method EPA 533

  • PFHxA — Sample date: 2024-12-16

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 0.003 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 810-131789-1 · Method EPA 533

  • PFHxA — Sample date: 2024-09-11

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 0.003 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 810-119951-1 · Method EPA 533

  • PFHxA — Sample date: 2024-12-18

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 0.003 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 810-132390-1 · Method EPA 533

  • PFHxA — Sample date: 2024-09-11

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 0.003 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 810-119947-1 · Method EPA 533

  • PFHxA — Sample date: 2024-12-16

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 0.003 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 810-131779-1 · Method EPA 533

  • PFHxA — Sample date: 2024-09-11

    Detected above reporting limit. = 0.0062 µg/L

    Reporting limit: 0.003 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 810-119962-1 · Method EPA 533

  • PFHxA — Sample date: 2025-09-24

    Detected above reporting limit. = 0.0061 µg/L

    Reporting limit: 0.003 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 810-165341-1 · Method EPA 533

  • PFHxA — Sample date: 2025-02-14

    Detected above reporting limit. = 0.005 µg/L

    Reporting limit: 0.003 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 810-138190-1 · Method EPA 533

  • PFHxA — Sample date: 2025-06-24

    Detected above reporting limit. = 0.0048 µg/L

    Reporting limit: 0.003 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample 810-153438-1 · Method EPA 533

Measurement evidence

Analyte
Perfluorohexanoic acid (PFHxA)
Result qualifier
=
Reference basis
400000.0 ng/L Michigan EGLE state MCL (strictest US state)
Sampling location
Entry Point to Distribution
Water system ID
SC1820001
Source ID
src-ucmr5-2024

Laboratory context

No laboratory method note was published with this record.

Sampling context

This result represents a entry point to distribution sample. It does not establish the condition at every distribution point or household tap.

Record limitation

System-level entry-point monitoring; not a measurement of the water at an individual household tap.

Source provenance

UCMR5 Analytical Results

Fifth Unregulated Contaminant Monitoring Rule (UCMR5) — PFAS occurrence data

U.S. Environmental Protection Agency · Published 2024

Nationwide entry-point monitoring for 29 PFAS and lithium under the fifth UCMR cycle. Results are entry-point-to-distribution samples, not household-tap measurements.

How to interpret this record

This page preserves one measurement. Interpretation requires its qualifier, reporting limit, reference basis, date, sampling location, and limitations; the number alone is not a safety verdict.

Review finding states →

Related intelligence