Forensic evidence record · ev-utah06015-f-bountiful-lithium

Lithium

A single published measurement record with its qualifier, sampling context, source identifier, method note, and stated limitations kept together.

Published evidence record

26.1 µg/LReported measurement
Back to water-system profile
26.1 µg/Lreported result
Not verified from sourcereporting limit
Sample date: 2023-01-24 to 2023-10-25sample date
2026-10-15publication date
Source observations (25)
  • lithium — Sample date: 2023-01-24

    Detected above reporting limit. = 26.1 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample MDA0706-10 · Method EPA 200.7

  • lithium — Sample date: 2023-07-19

    Detected above reporting limit. = 24.4 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample MDG0663-02 · Method EPA 200.7

  • lithium — Sample date: 2023-01-24

    Detected above reporting limit. = 19.7 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample MDA0706-03 · Method EPA 200.7

  • lithium — Sample date: 2023-04-27

    Detected above reporting limit. = 10.7 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample MDD0923-03 · Method EPA 200.7

  • lithium — Sample date: 2023-07-19

    Detected above reporting limit. = 21.4 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample MDG0663-01 · Method EPA 200.7

  • lithium — Sample date: 2023-10-25

    Detected above reporting limit. = 23.9 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample MDJ0876-01 · Method EPA 200.7

  • lithium — Sample date: 2023-01-24

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample MDA0706-01 · Method EPA 200.7

  • lithium — Sample date: 2023-04-27

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample MDD0923-02 · Method EPA 200.7

  • lithium — Sample date: 2023-07-19

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample MDG0663-08 · Method EPA 200.7

  • lithium — Sample date: 2023-10-25

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample MDJ0876-02 · Method EPA 200.7

  • lithium — Sample date: 2023-03-28

    Detected above reporting limit. = 25 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample MDC0956-01 · Method EPA 200.7

  • lithium — Sample date: 2023-07-19

    Detected above reporting limit. = 18.9 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample MDG0663-07 · Method EPA 200.7

  • lithium — Sample date: 2023-01-24

    Detected above reporting limit. = 24.4 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample MDA0706-05 · Method EPA 200.7

  • lithium — Sample date: 2023-07-19

    Detected above reporting limit. = 22.5 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample MDG0663-04 · Method EPA 200.7

  • lithium — Sample date: 2023-01-24

    Detected above reporting limit. = 12.1 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample MDA0706-09 · Method EPA 200.7

  • lithium — Sample date: 2023-04-27

    Detected above reporting limit. = 19.3 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample MDD0923-01 · Method EPA 200.7

  • lithium — Sample date: 2023-07-19

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample MDG0663-06 · Method EPA 200.7

  • lithium — Sample date: 2023-10-25

    Detected above reporting limit. = 16.6 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample MDJ0876-03 · Method EPA 200.7

  • lithium — Sample date: 2023-01-24

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample MDA0706-02 · Method EPA 200.7

  • lithium — Sample date: 2023-07-19

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample MDG0663-09 · Method EPA 200.7

  • lithium — Sample date: 2023-01-24

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample MDA0706-04 · Method EPA 200.7

  • lithium — Sample date: 2023-07-19

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample MDG0663-05 · Method EPA 200.7

  • lithium — Sample date: 2023-01-24

    Detected above reporting limit. = 14.1 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample MDA0706-08 · Method EPA 200.7

  • lithium — Sample date: 2023-07-19

    Detected above reporting limit. = 12.9 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample MDG0663-03 · Method EPA 200.7

  • lithium — Sample date: 2023-01-24

    Detected above reporting limit. = 16.9 µg/L

    Reporting limit: 9 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample MDA0706-06 · Method EPA 200.7

Measurement evidence

Analyte
Lithium
Result qualifier
=
Reference basis
10.0 µg/L EPA health reference level (screening, not a legal limit)
Sampling location
Entry Point to Distribution
Water system ID
UTAH06015
Source ID
src-ucmr5-2024

Laboratory context

No laboratory method note was published with this record.

Sampling context

This result represents a entry point to distribution sample. It does not establish the condition at every distribution point or household tap.

Record limitation

System-level entry-point monitoring; not a measurement of the water at an individual household tap.

Source provenance

UCMR5 Analytical Results

Fifth Unregulated Contaminant Monitoring Rule (UCMR5) — PFAS occurrence data

U.S. Environmental Protection Agency · Published 2024

Nationwide entry-point monitoring for 29 PFAS and lithium under the fifth UCMR cycle. Results are entry-point-to-distribution samples, not household-tap measurements.

How to interpret this record

This page preserves one measurement. Interpretation requires its qualifier, reporting limit, reference basis, date, sampling location, and limitations; the number alone is not a safety verdict.

Review finding states →

Related intelligence