Forensic evidence record · ev-wi4450333-f-appleton-pfba

Perfluorobutanoic acid (PFBA)

A single published measurement record with its qualifier, sampling context, source identifier, method note, and stated limitations kept together.

Published evidence record

5.9 ng/LReported measurement
Back to water-system profile
5.9 ng/Lreported result
Not verified from sourcereporting limit
Sample date: 2023-12-06 to 2024-09-10sample date
2026-01-15publication date
Source observations (4)
  • PFBA — Sample date: 2023-12-06

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 0.005 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample CB14876-01 · Method EPA 533

  • PFBA — Sample date: 2024-03-12

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 0.005 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample CC02710-01 · Method EPA 533

  • PFBA — Sample date: 2024-07-01

    Below reporting limit. < Result value not available µg/L

    Reporting limit: 0.005 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample CC07262-01 · Method EPA 533

  • PFBA — Sample date: 2024-09-10

    Detected above reporting limit. = 0.0059 µg/L

    Reporting limit: 0.005 µg/L. Detection limit: Not available. Benchmark unavailable

    Source: src-ucmr5-2024 · UCMR5_All.txt · Sample CC10845-01 · Method EPA 533

Measurement evidence

Analyte
Perfluorobutanoic acid (PFBA)
Result qualifier
=
Reference basis
No federal or state limit; shown for transparency
Sampling location
Entry Point to Distribution
Water system ID
WI4450333
Source ID
src-ucmr5-2024

Laboratory context

No laboratory method note was published with this record.

Sampling context

This result represents a entry point to distribution sample. It does not establish the condition at every distribution point or household tap.

Record limitation

System-level entry-point monitoring; not a measurement of the water at an individual household tap.

Source provenance

UCMR5 Analytical Results

Fifth Unregulated Contaminant Monitoring Rule (UCMR5) — PFAS occurrence data

U.S. Environmental Protection Agency · Published 2024

Nationwide entry-point monitoring for 29 PFAS and lithium under the fifth UCMR cycle. Results are entry-point-to-distribution samples, not household-tap measurements.

How to interpret this record

This page preserves one measurement. Interpretation requires its qualifier, reporting limit, reference basis, date, sampling location, and limitations; the number alone is not a safety verdict.

Review finding states →