Short answer: In the 2023–2025 records we hold for New Orleans Algiers, PFOS had a sample above a 2024 EPA limit (not a violation: the limit is judged on a yearly average, due 2029), and 4 health-based violations are on record (EPA SDWIS). Also worth knowing: lithium sits above a screening level. 5 substances were detected and 26 were tested and not detected. The water is from New Orleans Algiers Water Works, serving 52,785 residents.
PFOSPerfluorooctanesulfonic acid (PFOS)Above EPA's 2024 limit (one sample) · Federal MCL4.0 ng/L federal MCL (2024)4.5ng/L▾
① · Measured
4.5 ng/L, sampled 2023-03-07 to 2023-12-06. EPA UCMR 5.
② · Compared
4.0 ng/L federal MCL (2024): a legal limit. That limit is judged on a yearly average, and water systems have until 2029 to meet it, so a single sample is not a violation. EPA health goal (MCLG): 0.
③ · Meaning
One EPA sample measured 4.5 ng/L, above the 4 ng/L limit EPA set in 2024. That limit is judged on a yearly average, and water systems have until 2029 to meet it, so a single sample is not a violation.
④ · Where it matters
Comes with the source water; home plumbing does not add it.
⑤ · What to do
Test your own tap first. To reduce it: Reverse osmosis, or carbon certified for PFAS (NSF/ANSI 53 or 58 (PFOA/PFOS)).
PFOAPerfluorooctanoic acid (PFOA)Within reference · Federal MCL4.0 ng/L federal MCL (2024)4ng/L▾
① · Measured
4 ng/L, sampled 2023-03-07 to 2023-12-06. EPA UCMR 5.
② · Compared
4.0 ng/L federal MCL (2024): a legal limit. That limit is judged on a yearly average, and water systems have until 2029 to meet it. EPA health goal (MCLG): 0.
③ · Meaning
Detected at up to 4 ng/L (below the 4 ng/L limit EPA set in 2024). That limit is judged on a yearly average, and water systems have until 2029 to meet it.
④ · Where it matters
Comes with the source water; home plumbing does not add it.
⑤ · What to do
Test your own tap first. To reduce it: Reverse osmosis, or carbon certified for PFAS (NSF/ANSI 53 or 58 (PFOA/PFOS)).
NEW ORLEANS ALGIERS WATER WORKS (EPA PWSID LA1071001) delivers surface water to 52,785 residents. This report reflects 29 individual PFAS result(s) from the source UCMR5 observations and the latest Lead & Copper Rule 90th-percentile result. Water hardness and disinfectant type are pending the utility's own annual report.
Track record
4health-based violations in the last 10 years
From EPA SDWIS. Counted once per contaminant per year, as in the Track record score. All 7 EPA filings are listed below.
Not in this recordDisinfection by-products weren't monitored in this dataset
No result is not a pass. Your utility's annual water quality report may list them, and a certified lab test covers your own tap.
Health-based violations, last 10 years
Every filing is listed; the Track record score counts at most one per contaminant per year.
The record describes water leaving treatment and samples across the system. Pipes, solder and fixtures inside a building can add lead the record can’t see, especially in older buildings with lead service lines.
Filters for the PFAS found in New Orleans Algiers water
Affiliate linksPurityMap earns a commission from these links. "Best choice" and "Budget pick" go to certified products first; commission never decides them. As an Amazon Associate, PurityMap earns from qualifying purchases. Affiliate disclosure
★ Best choice: Aquasana Claryum 2-Stage Under-Sink Filter (AQ-5200), certified for PFOS, PFOA and lead.
Filters for the PFAS found in New Orleans Algiers water
Reverse osmosisiSpring RCC7AK Alkaline Reverse Osmosis SystemiSpring · It treats only the water from its own faucet and sends part of the water to the drain; the NSF listing for the plain RCC7AK covers dissolved solids, not lead or PFAS.Use code REFISPRING at checkout: 10% off your first iSpring order.
Reverse osmosisiSpring RO5004F Tankless Reverse Osmosis System with UViSpring · Its PFAS and lead reduction claims are iSpring's own, with no third-party certification named for this model, and it treats only the water at its own faucet.Use code REFISPRING at checkout: 10% off your first iSpring order.
Reverse osmosisWaterdrop X12 Reverse Osmosis SystemWaterdrop · Its IAPMO NSF/ANSI 58 certification covers TDS reduction only, so its PFAS and lead claims rest on Waterdrop's own SGS lab testing.
Whole-houseiSpring WGB32B-PFKS PFAS & Heavy Metals Whole House FilteriSpring · It does not reduce total dissolved solids or soften hard water, and its PFAS result comes from SGS lab testing rather than an NSF/ANSI certification.Use code REFISPRING at checkout: 10% off your first iSpring order.
PurityMap earns a commission from these links. "Best choice" and "Budget pick" go to certified products first; commission never decides them. As an Amazon Associate, PurityMap earns from qualifying purchases. Affiliate disclosure.
Lead service lines
Ask your utility first
New Orleans Algiers Water Works reported 905 lead service lines to replace in EPA’s inventory (2026Q2). Many utilities replace these lines for free or share the cost. Ask New Orleans Algiers Water Works whether your home’s line is on its list before you pay anyone.
Local help
Think your plumbing may be adding lead?
Call to be connected with a local plumbing provider about lead service lines, repiping or fixture replacement.
Your path: I live in an older buildingLead from plumbing is the main question
Older buildings may have lead service lines, solder or fixtures. New Orleans Algiers’ record shows lead at 5.6 µg/L (15 µg/L federal action level). Test first-draw water, then filter if needed.
3 of 29 PFAS tested were detected in New Orleans Algiers’ record (PFOS 4.5 ng/L, PFOA 4 ng/L and PFBA 8.5 ng/L); 1 above its limit. If PFAS matters to you, a filter certification names each compound it covers.
Look forNSF/ANSI 53 or 58, with each compound you care about named on the listing
Your path: My water tastes of chlorineThe disinfectant is not in this record
Most utilities keep chlorine or chloramine in the pipes. A carbon filter certified for taste and odor reduces either; your utility can tell you which it uses.
PurityMap does not give a safe/unsafe verdict; it shows what the public records measured. For New Orleans Algiers, PFOS 4.5 ng/L was measured in one EPA sample, above the 4 ng/L limit EPA set in 2024 (not a violation: the limit is judged on a yearly average, due 2029); the lead 90th-percentile result was 5.6 µg/L against the 15 µg/L action level. NEW ORLEANS ALGIERS WATER WORKS (PWSID LA1071001) has a Purity Score of 63/100 (confidence: moderate), assessed at the water-system level and computed only from contaminants that were measured. Water can change in your own pipes, so a certified test is the only way to know what comes out of your tap. What we found →
Who provides tap water in New Orleans Algiers?+
NEW ORLEANS ALGIERS WATER WORKS (PWS ID LA1071001) is the public water system on record for New Orleans Algiers, Louisiana, serving about 52,785 people. Confirm the utility on your water bill before acting on a specific finding. Water utility →
Where does New Orleans Algiers get its drinking water?+
Surface water (primary source of record in EPA SDWIS). Water utility →
Are PFAS "forever chemicals" in New Orleans Algiers's water?+
Yes. In EPA's UCMR 5 testing (2023-03-07 to 2023-12-06), PFOS was measured at 4.5 ng/L in one EPA sample, above the 4 ng/L limit EPA set in 2024. That limit is judged on a yearly average, and water systems have until 2029 to meet it, so a single sample is not a violation. PFOA was detected below its limit. PFBA (8.5 ng/L) was also detected; it has no federal or state limit. Reverse osmosis and filters certified to NSF/ANSI 53 for PFOA/PFOS reduce them at the tap. What we found →
Is there lead in New Orleans Algiers's tap water?+
NEW ORLEANS ALGIERS WATER WORKS's most recent lead 90th-percentile result (2023–2025) was 5.6 µg/L, below the 15 µg/L action level. That figure comes from sampled homes; lead usually enters from a building's own pipes and fixtures, so only a test at your tap tells you what you drink. Your household →
What does the latest New Orleans Algiers water report show?+
PurityMap's current record for New Orleans Algiers holds 31 findings: 2 above a reference, 2 detected within the reference, 1 detected with no limit and 26 not detected. Each finding links to its dated public record; a parameter that was never monitored is shown as pending, not as a pass. Records →
EPA SDWIS, EPA UCMR 5 and utility reports, each dated and linked.
02Normalize
Units converted to one basis; a non-detect kept distinct from zero.
03Classify
Each result tagged by reference type: MCL, action level, screening level or aesthetic.
04Compare to the named reference
Every value sits against its own reference, never a blended one.
05Score
Measured subjects summarised at the water-system level; an open health-based violation caps the score.
06Match treatment
Treatment is matched to what was found; a product is called certified only when its current certification names it.
What the Purity Score means: a summary of this water system’s published record, capped while a health-based violation is open. It is not a test of any tap. NEW ORLEANS ALGIERS WATER WORKS · PWSID LA1071001 · Purity Score 63/100 (Fair) · Confidence: moderate · Assessed at the water-system level
Lead at New Orleans Algiers Water Works: 5.6 µg/L (90th percentile, 2023–2025 monitoring period). Lead has no taste, so a taste neither shows nor rules it out.